February 5, 2009 - Use of the imaging technique known as cardiac computed tomography (CT) angiography (CCTA) has the potential to expose patients to high doses of radiation, and methods available to reduce radiation dose are not frequently used, according to a study in the February 4 issue of JAMA. The 64-slice (able to scan 64 images per rotation) CCTA has emerged as a useful diagnostic imaging method for the assessment of coronary artery disease and has been proposed to be useful for evaluating patients in emergency departments with chest pain. "With the constantly increasing number of CCTA-capable scanners worldwide, the volume of CCTA scans performed is likely to show substantial further increase," the authors write. They add that the clinical usefulness of CCTA for the assessment of coronary artery disease has to be weighed against the radiation exposure of CCTA and the small but potential risk of cancer. Many clinicians may still be unfamiliar with the magnitude of radiation exposure that is received during CCTA in daily practice and with the factors that contribute to radiation dose, according to background information in the article. Jörg Hausleiter, M.D., of the Deutsches Herzzentrum München, Klinik an der Technischen Universität München, Munich, Germany, and colleagues investigated the magnitude of radiation dose of CCTA in daily practice, factors contributing to radiation dose and the use of currently available strategies to reduce radiation dose. The trial, the Prospective Multicenter Study On Radiation Dose Estimates Of Cardiac CT Angiography In Daily Practice I (PROTECTION I), an international, multicenter study (21 university hospitals and 29 community hospitals) included 1,965 patients undergoing CCTA between February and December 2007. Analysis was used to identify independent predictors associated with radiation dose, which was measured as dose-length product (DLP; equals the average radiation dose over a specific investigated volume multiplied by the scan length), which best mirrors the radiation a patient is exposed to by the entire CT scan, according to the authors. The researchers found that the median (midpoint) DLP of the patients in the study was 885 mGy-cm (a measurement of absorbed radiation), which corresponds to an estimated radiation dose of 600 chest x-rays. A high variability in DLP was observed between study sites (range of median DLPs per site, 331-2,146 mGy-cm). Independent factors associated with radiation dose were patient weight (relative effect on DLP, 5 percent); absence of stable sinus rhythm (type of heart rhythm; 10 percent effect); scan length (a 1-cm increase in the scan length was associated with a 5 percent increase in DLP); the use of electrocardiographically controlled tube current modulation (resulting in a reduction of DLP of 25 percent, applied in 73 percent of patients); 100-kV (kilo volts) tube voltage (46 percent reduction of DLP, applied in 5 percent of patients); sequential scanning (78 percent reduction; applied in 6 percent of patients); experience in cardiac CT (1 percent reduction); number of CCTAs per month; and type of 64-slice CT system (for highest vs. lowest dose system, 97 percent effect). "… the study demonstrates that radiation exposure can be reduced substantially by uniformly applying the currently available strategies for dose reduction, but these strategies are used infrequently," the authors write. "… an improved education of physicians and technicians performing CCTA on these dose-saving strategies might be considered to keep the radiation dose 'as low as reasonably achievable' in every patient undergoing CCTA." "As CCTA is being used more frequently worldwide for diagnosing coronary artery disease, all strategies for reducing radiation exposure will finally reduce the patient's lifetime cancer risks. Although the associated risk is small (estimated lifetime attributable risk of death from cancer after an abdominal CT scan is 0.02 percent) relative to the diagnostic information for most CT studies, this risk needs to be realized especially when repeated CT scans are being performed." Source: JAMA. 2009;301[5]:500-507 For more information: jama.ama-assn.org


Related Content

News | FDA

Nov. 26, 2025 — a2z Radiology AI has received U.S. FDA clearance for a2z-Unified-Triage, a single device that flags and ...

Time December 03, 2025
arrow
News | RSNA 2025

Nov. 13, 2025 — Nano-X Imaging Ltd., a medical imaging technology company, will showcase its Nanox.ARC X multi-source ...

Time November 25, 2025
arrow
News | Interventional Radiology

Nov. 12, 2025 — On Nov. 11, Huntsman Cancer Institute at the University of Utah (the U) opened its first specialized ...

Time November 13, 2025
arrow
Feature | Teleradiology | Kyle Hardner

Once viewed as a solution for after-hours coverage, teleradiology is rapidly expanding into a critical part of radiology ...

Time November 06, 2025
arrow
News | Radiology Imaging | UC San Diego Health

Oct. 16, 2025 — A strategic collaboration between UC San Diego Health and GE HealthCare will focus on bringing advanced ...

Time October 20, 2025
arrow
News | Mammography

Sept. 3, 2025 — According to ARRS’ American Journal of Roentgenology (AJR), a commercial artificial intelligence (AI) ...

Time September 09, 2025
arrow
News | Lung Imaging

Aug. 26, 2025 — Optellum, a global leader in AI for lung health, recently announced the world’s first thorax CT ...

Time August 26, 2025
arrow
News | RSNA 2025

Aug. 13, 2025 — Registration is now open for the RSNA 111th Scientific Assembly and Annual Meeting, the world’s leading ...

Time August 13, 2025
arrow
News | Artificial Intelligence

July 22, 2025 — GE HealthCare has topped a U.S. Food and Drug Administration (FDA) list of AI-enabled medical device ...

Time July 23, 2025
arrow
News | Breast Imaging

QT Imaging Holdings, Inc. has announced the launch of its latest QTviewer, version 2.8. QTviewer stores and displays the ...

Time July 21, 2025
arrow
Subscribe Now