News | February 05, 2009

CCTA May Expose Patients to High Radiation Dose Reports JAMA

February 5, 2009 - Use of the imaging technique known as cardiac computed tomography (CT) angiography (CCTA) has the potential to expose patients to high doses of radiation, and methods available to reduce radiation dose are not frequently used, according to a study in the February 4 issue of JAMA. The 64-slice (able to scan 64 images per rotation) CCTA has emerged as a useful diagnostic imaging method for the assessment of coronary artery disease and has been proposed to be useful for evaluating patients in emergency departments with chest pain. "With the constantly increasing number of CCTA-capable scanners worldwide, the volume of CCTA scans performed is likely to show substantial further increase," the authors write. They add that the clinical usefulness of CCTA for the assessment of coronary artery disease has to be weighed against the radiation exposure of CCTA and the small but potential risk of cancer. Many clinicians may still be unfamiliar with the magnitude of radiation exposure that is received during CCTA in daily practice and with the factors that contribute to radiation dose, according to background information in the article. Jörg Hausleiter, M.D., of the Deutsches Herzzentrum München, Klinik an der Technischen Universität München, Munich, Germany, and colleagues investigated the magnitude of radiation dose of CCTA in daily practice, factors contributing to radiation dose and the use of currently available strategies to reduce radiation dose. The trial, the Prospective Multicenter Study On Radiation Dose Estimates Of Cardiac CT Angiography In Daily Practice I (PROTECTION I), an international, multicenter study (21 university hospitals and 29 community hospitals) included 1,965 patients undergoing CCTA between February and December 2007. Analysis was used to identify independent predictors associated with radiation dose, which was measured as dose-length product (DLP; equals the average radiation dose over a specific investigated volume multiplied by the scan length), which best mirrors the radiation a patient is exposed to by the entire CT scan, according to the authors. The researchers found that the median (midpoint) DLP of the patients in the study was 885 mGy-cm (a measurement of absorbed radiation), which corresponds to an estimated radiation dose of 600 chest x-rays. A high variability in DLP was observed between study sites (range of median DLPs per site, 331-2,146 mGy-cm). Independent factors associated with radiation dose were patient weight (relative effect on DLP, 5 percent); absence of stable sinus rhythm (type of heart rhythm; 10 percent effect); scan length (a 1-cm increase in the scan length was associated with a 5 percent increase in DLP); the use of electrocardiographically controlled tube current modulation (resulting in a reduction of DLP of 25 percent, applied in 73 percent of patients); 100-kV (kilo volts) tube voltage (46 percent reduction of DLP, applied in 5 percent of patients); sequential scanning (78 percent reduction; applied in 6 percent of patients); experience in cardiac CT (1 percent reduction); number of CCTAs per month; and type of 64-slice CT system (for highest vs. lowest dose system, 97 percent effect). "… the study demonstrates that radiation exposure can be reduced substantially by uniformly applying the currently available strategies for dose reduction, but these strategies are used infrequently," the authors write. "… an improved education of physicians and technicians performing CCTA on these dose-saving strategies might be considered to keep the radiation dose 'as low as reasonably achievable' in every patient undergoing CCTA." "As CCTA is being used more frequently worldwide for diagnosing coronary artery disease, all strategies for reducing radiation exposure will finally reduce the patient's lifetime cancer risks. Although the associated risk is small (estimated lifetime attributable risk of death from cancer after an abdominal CT scan is 0.02 percent) relative to the diagnostic information for most CT studies, this risk needs to be realized especially when repeated CT scans are being performed." Source: JAMA. 2009;301[5]:500-507 For more information: jama.ama-assn.org

Related Content

Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
The Fujifilm FCT Embrace CT System displayed for the first time at ASTRO 2018.
360 Photos | 360 View Photos | November 07, 2018
Fujifilm's first FDA-cleared compu...
MaxQ AI Receives FDA Clearance for Accipio Ix Intracranial Hemorrhage Platform
Technology | Artificial Intelligence | November 07, 2018
MaxQ AI announced that its Accipio Ix intracranial hemorrhage (ICH) detection software has received 510(k) clearance...
GE Healthcare Discovery RF Gen 2 system displayed at ASTRO 2018. It is a dedicated computed tomography (CT) scanner for radiation oncology
360 Photos | 360 View Photos | November 07, 2018
This is the GE Healthcare Discovery RF Gen 2 system displayed at the ...
Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Sponsored Content | Case Study | Computed Tomography (CT) | November 06, 2018
The following is a summary of a study published in the
The NeuViz 16 Essence from Neusoft Medical Systems.

The NeuViz 16 Essence from Neusoft Medical Systems.

Feature | Computed Tomography (CT) | November 05, 2018 | By Melinda Taschetta-Millane
According to an industry mark...
Carestream Spotlights Healthcare IT and Imaging Systems at RSNA 2018
News | Information Technology | October 31, 2018
Carestream announced it will be displaying several imaging and healthcare information technology (IT) offerings at the...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...
Fujifilm Unveils FCT Embrace CT System for Oncology
Technology | Computed Tomography (CT) | October 23, 2018
Fujifilm Medical Systems U.S.A. Inc. recently introduced the FCT Embrace computed tomography (CT) system. Powered by...
The Aquilion Precision CT system from Canon offers very high resolution imaging, which may aid in cancer detection and improved treatment planning in radiation oncology. #ASTRO2018 #ASTRO #ASTRO18

The Aquilion Precision CT system from Canon offers very high resolution imaging, which may aid in cancer detection and improved treatment planning in radiation oncology. 

News | Computed Tomography (CT) | October 19, 2018
October 19, 2018 – At the 2018 American Society of...