News | November 29, 2007

Study: Radiation Exposure of Pregnant Women More than Doubles in 10 Years

November 30, 2007 - According to a study presented at RSNA, an unprecedented increase in the use of radiologic exams on pregnant women has present in the past decade, finding that from 1997 to 2006, the number of imaging studies performed on pregnant women increased by 121 percent.

The researchers conducted a retrospective review of selected imaging examinations, nuclear medicine, computed tomography (CT) and plain-film X-rays, performed at Brown to determine how often these imaging exams were utilized in pregnant women and the estimated resulting radiation dose to the fetus. Data were compiled for the years 1997 through 2006 and compared to the number of infant deliveries per year.

CT is not routinely used in pregnancy, but pregnant women may undergo CT to detect suspected life-threatening conditions such as bleeding in the brain, blood clots in the lungs or appendicitis. Since CT exposes the developing fetus to radiation, concerns are often raised regarding overuse. The majority of CT examinations (approximately 75 percent) analyzed in the study were performed in areas of the mother's body separate from the uterus, so the fetus was not exposed to any direct radiation. Even low levels of radiation have been shown to carry a small risk of harm to a developing fetus.

The researchers evaluated 5,235 examinations on 3,249 patients. During the 10 years of the study, the number of patients imaged per year increased from 231 to 447, and the number of exams per year increased from 325 to 730. This represented an 89 percent increase in patients and a 121 percent increase in examinations over the course of the study. During the same 10 years, the number of deliveries only increased from 8,661 to 9,261, a rise of only 7 percent or less than 1 percent annually.

Use of plain-film X-rays increased an average of 7 percent per year, and the number of nuclear medicine examinations rose by approximately 12 percent annually. CT examinations increased by approximately 25 percent per year. The average estimated fetal radiation exposure for CT was 0.69 rads, compared to 0.04 rads for nuclear medicine and 0.0015 rads for plain-film X-rays.

Other studies have shown that use of high-tech modalities, such as CT and magnetic resonance imaging (MRI), has increased in all patient populations throughout the United States. According to Dr. Lazarus, some of this increase is due to the development of new imaging techniques to better diagnose abnormalities, and some is due to motivation by hospitals and insurers to make fast diagnoses to shorten hospital stays and improve patient care.

Dr. Lazarus cautions healthcare consumers to be aware of this trend. "I want to assure patients that CT can be a safe, effective test for pregnant patients," she said. "However, there are alternatives that should at least be explored. Pregnant patients should ask their doctors about other imaging or diagnostic tests that may not expose the fetus to radiation."

For more information: www.rsna.org

Related Content

Video Plus Brochure Helps Patients Make Lung Cancer Scan Decision

Image courtesy of the American Thoracic Society

News | Lung Cancer | April 19, 2019
A short video describing the potential benefits and risks of low-dose computed tomography (CT) screening for lung...
FDA Clears GE's Deep Learning Image Reconstruction Engine
Technology | Computed Tomography (CT) | April 19, 2019
GE Healthcare has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) of its Deep Learning Image...
Videos | RSNA | April 03, 2019
ITN Editor Dave Fornell takes a tour of some of the most interesting new medical imaging technologies displa
Johns Hopkins Medicine First in U.S. to Install Canon Medical's Aquilion Precision
News | Computed Tomography (CT) | March 26, 2019
March 26, 2019 — Johns Hopkins Medicine now has access to the first...
At #ACC.19, Siemens unveiled a version of its go.Top platform optimized for cardiovascular imaging. The newly packaged scanner can generate the data needed to do CT-based FFR (fractional flow reserve).

At #ACC.19, Siemens unveiled a version of its go.Top platform optimized for cardiovascular imaging. The newly packaged scanner can generate the data needed to do CT-based FFR (fractional flow reserve). Photo by Greg Freiherr

Feature | Cardiac Imaging | March 22, 2019 | By Greg Freiherr
Reflecting a trend toward the increased use of...
Researchers Use Radiomics to Predict Who Will Benefit from Chemotherapy
News | Radiomics | March 21, 2019
Using data from computed tomography (CT) images, researchers may be able to predict which lung cancer patients will...
HeartFlow Analysis Successfully Stratifies Heart Disease Patients at One Year
News | CT Angiography (CTA) | March 19, 2019
Late-breaking results confirm the HeartFlow FFRct (fractional flow reserve computed tomography) Analysis enables...
Podcast | Cardiac Imaging | March 15, 2019
Debate About Coronary Testing Highlights ACC Session
Canon Medical Introduces Entry-Level Aquilion Start CT
News | Computed Tomography (CT) | March 14, 2019
Canon Medical Systems Europe B.V. introduced the all-new Aquilion Start computed tomography (CT) system to the European...
Siemens Healthineers Debuts Cardiovascular Edition of Somatom go.Top CT
News | Computed Tomography (CT) | March 14, 2019
Siemens Healthineers will introduce the Somatom go.Top Cardiovascular Edition, a new version of its established...