News | Computed Tomography (CT) | December 15, 2022

AJR guides optimization of clinical protocols when implementing ultra-high-resolution photon-counting detector (UHR PCD) CT of the lungs, providing insights on the association of reconstruction kernel and slice thickness with image quality.

61-year-old male, post lung transplant, who underwent photon-counting detector CT of chest in ultra-high-resolution mode. Reconstructions were performed at 0.2-mm slice thickness with BI56 kernel (A), BI60 kernel (B), and BI64 kernel (C); at 0.4-mm slice thickness with BI56 kernel (D), BI60 kernel (E), and BI64 kernel (F); and at 1.0-mm slice thickness with BI56 kernel (G), BI60 kernel (H), and BI64 kernel (I). Clinical-reference reconstruction (BI64 kernel at 1.0-mm slice thickness) is shown with red outli

61-year-old male, post lung transplant, who underwent photon-counting detector CT of chest in ultra-high-resolution mode. Reconstructions were performed at 0.2-mm slice thickness with BI56 kernel (A), BI60 kernel (B), and BI64 kernel (C); at 0.4-mm slice thickness with BI56 kernel (D), BI60 kernel (E), and BI64 kernel (F); and at 1.0-mm slice thickness with BI56 kernel (G), BI60 kernel (H), and BI64 kernel (I). Clinical-reference reconstruction (BI64 kernel at 1.0-mm slice thickness) is shown with red outline in lower right (I). Small bronchus with wall discontinuity, corresponding to origin of bronchial division, is well visualized on reconstructions at 0.2-mm and 0.4-mm slice thickness with Bl60 and Bl64 kernels (arrows), but not on clinical-reference reconstruction. All images displayed with window of -400 HU and level of 1400 HU.


December 15, 2022 —  An accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR) guides optimization of clinical protocols when implementing ultra-high-resolution photon-counting detector (UHR PCD) CT of the lungs, providing insights on the association of reconstruction kernel and slice thickness with image quality.

Evaluating the impact of kernel and slice thickness on image quality of UHR PCD CT of the lungs using a 1024x1024 matrix, “the sharpest evaluated kernel, BI64, was the optimal kernel, consistent with the current clinical-reference technique,” wrote corresponding author Helmut Prosch from the department of biomedical imaging and image-guided therapy at the Medical University of Vienna in Austria.

In this AJR accepted manuscript, 29 patients (17 women, 12 men; median age, 56 years) underwent noncontrast chest CT using a first-generation PCD scanner (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) from February 15 to March 15, 2022. All acquisitions used UHR mode. Nine image sets were reconstructed for all combinations of three sharp kernels (BI56, BI60, BI64) and three slice thicknesses (0.2, 0.4, 1.0 mm). Three radiologists independently reviewed reconstructions for measures of visualization of pulmonary anatomic structures and pathologies using clinical-reference: BI641.0-mm.

Ultimately, when performing PCD CT of the lungs in UHR mode, reconstruction using BI64 kernel and 0.4-mm slice thickness was the only assessed reconstruction to yield improved bronchial division identification and bronchial wall and pulmonary fissure sharpness, without loss in pulmonary vessel sharpness or conspicuity of nodules or other pathologies.

In comparison, a 0.2-mm slice thickness—the thinnest reconstruction possible—was “associated with decreased visualization of various anatomic and pathologic findings,” the authors of this AJR accepted manuscript added.

For more information: www.arrs.org


Related Content

News | Radiation Oncology

March 4, 2026 — Lunit has announced that 21 studies featuring its AI solutions will be presented at the European ...

Time March 05, 2026
arrow
News | Artificial Intelligence

March 2, 2026 — RadNet, Inc. has acquired Gleamer SAS, a radiology AI company based in Paris, France. Gleamer will be ...

Time March 03, 2026
arrow
News | Ultrasound Imaging

March 2, 2026 — Esaote Group will officially launch the new MyLab E85 and MyLab C30 GTS Edition ultrasound systems at ...

Time March 02, 2026
arrow
News | Remote Viewing Systems

Feb. 26, 2026 — DeepHealth, Inc., a provider of AI-powered health informatics and a wholly owned subsidiary of RadNet ...

Time February 27, 2026
arrow
News | FDA

Feb. 26, 2026 — The U.S. Food and Drug Administration (FDA) has given 510(k) class II clearance of qXR-Detect, the ...

Time February 26, 2026
arrow
News | Magnetic Resonance Imaging (MRI)

Feb. 9, 2026 — MRIguidance, a MedTech company developing BoneMRI, a radiation-free bone imaging solution, has appointed ...

Time February 09, 2026
arrow
Feature | Cardiac Imaging | Kyle Hardner

Advances in coronary CT angiography (CCTA) have reached the point where image quality and AI capabilities are creating ...

Time February 06, 2026
arrow
News | Point-of-Care Ultrasound (POCUS)

Jan. 22, 2026 — Qure.ai has received a grant from the Gates Foundation to develop a large open-source multi-modal ...

Time January 23, 2026
arrow
News | Artificial Intelligence

Dec. 1, 2025 — Researchers at the University of California, Berkeley and University of California, San Francisco have ...

Time December 10, 2025
arrow
News | FDA

Nov. 26, 2025 — a2z Radiology AI has received U.S. FDA clearance for a2z-Unified-Triage, a single device that flags and ...

Time December 03, 2025
arrow
Subscribe Now