Feature | December 07, 2012

Increasing Efficiency, Quantification With New MRI Software

New magnetic resonance imaging software automates segmentation, analysis of cardiovascular studies

Siemens, syngo.MR Cardiac 4-D, MRI software

The Siemens Healthcare syngo.MR Cardiac 4-D ventricular function software calculates relevant parameters and automatically segments the right ventricle. MRI analysis software help automate segmentation and calculations to more quickly assess patients.

Increasingly software applications are providing many of the major advancements in magnetic resonance imaging (MRI) rather than hardware. In recent years, this has translated into software that enables physicians to do more in less time, extract more diagnostic information from imaging exams and provide more accurate quantification. While a hospital may not spend millions to upgrade its MRI system, it frequently takes advantage of the lower cost option of other vendors’ software to assess and manipulate those images. 

A considerable amount of time can be spent slicing dataset images and using filters to find the exact part of the anatomy and information needed. This has been a barrier to wider adoption of MRI advanced visualization analysis software, but automation has drastically reduced the time needed manipulating images. 

In addition to being the modality of choice for anatomical soft tissue imaging, MRI also offers functional assessment, which is enabled by newer software.  

Analysis

Today’s MRI analysis software can calculate ventricular volumes, ejection fraction, myocardial mass and myocardial thickening for all segments. Many times these functions are automated to save time. Some software can perform dynamic evaluations, such as time-volume diagrams, filling rate and myocardial wall motion. It also presents information and a graphical display of results in tables, bull’s-eye plots and 4-D models of the heart. In addition, the information obtained by the software has the ability to be integrated into radiology or cardiology reports for documentation. 

TomTec introduced its new 2-D Cardiac Performance Analysis MR software product during the Society for Cardiovascular Magnetic Resonance (SCMR) 2012 meeting. The tool quantifies myocardial function and deformation based on regular cardiac MRI. It allows a cardiologist to study the function of the heart muscle quickly and easily, offering quantification of displacement, velocity and strain in individual muscle segments to help assess hypertrophic cardiomyopathy or dyssynchrony of ventricles.

2-D Cardiac Performance Analysis MR is a feature tracking-based analysis tool that supports 2-D data from various cardiac MR systems. It analyzes myocardial deformation in standard MR cine sequences and does not require specific acquisition modes like tagged imaging. Existing patient data can be used for follow-up comparisons.

The software, which gained FDA approval in April, is a vendor independent software solution for the quantification of myocardial function with “cardiac MR cine images”. It presents a novel method to analyze myocardial deformation from routine cardiac MR images, which have been acquired as part of a conventional cardiovascular MR examination – no time-consuming tagging
is necessary.

Access

TeraRecon launched its iNtuition Review, iNtuition Enterprise Medical Viewer (iEMV) and iNtuition Share software enhancements in September, which enable Web-based access to multimodality advanced visualization software. It also allows easy sharing of images and datasets over the Web. 

Automation

All MRI software vendors have automated features of their software so when a pre-specified type of study is opened, it renders “hands-off” in a pre-processed format without the need for user manipulation. Standard on some systems is auto segmentation of the coronary arteries and the endo- and epicardial left ventricular heart wall on short- and/or long axis images.

An example of automation using Siemens’ syngo.MR Cardiac 4-D Ventricular Function software is instant display of preprocessed segmentation of the left ventricle without user intervention. The software automatically calculates ventricular volumes, ejection fraction, myocardial mass and myocardial thickening for all segments. It also has semiautomatic processing of the right ventricle. 

Web-Enabled Analysis

Calgary Scientific received U.S. Food and Drug Administration (FDA) clearance to market earlier this year for its ResolutionMD Web 2.9 Vessel Analysis module for post-processing diagnostic review and analysis of patient computed tomography (CT) and magnetic resonance imaging (MRI) scans. The module allows physicians, technologists and surgeons to review, edit, analyze and report findings of vascular anatomy across applicable specialties. Having the ability to use these tools over the Web brings added value as physicians can access images from home computers and laptops, providing freedom to work anywhere, even when an advanced clinical application or analysis is needed.

Beyond the Coronaries

Specialized software is available for peripheral and carotid artery and neurovascular imaging. 

GE Healthcare recently partnered with VPDiagnostics Inc. to co-market the VPDiagnostics’ MRI-PlaqueView software for carotid artery atherosclerosis analysis. The software is compatible with carotid magnetic resonance imaging (MRI) data acquired from GE 3.0T MRI systems. The collaboration aims to develop optimized carotid imaging protocols and future co-developments on new techniques. Carotid atherosclerosis may be responsible for as much as one-third of all strokes and the software will help assess the risk of stroke from carotid atherosclerosis

VasSol’s Noninvasive Optimum Vessel Analysis (NOVA) technology provides detailed, quantitative information of blood flow through any vessel in the brain. Information provided includes velocity, volume and direction. It provides important quantitative data on what’s happening inside a blood vessel, as well as enhanced vessel visualization that raw MRI alone can not provide. The software does not require contrast injections.   

Comparison Chart

This article served as an introduction to an MRI software chart comparing verious vendor's software. To access the chart, click on the "comparison charts" link on the navigation bar at the top of the page. Companies that participated in  the chart include:

aycan Medical — www.aycan.com

AZE Ltd. — www.aze.co.jp/en

Circle Cardiovascular Imaging Inc. — www.circlecvi.com

Diagnosoft — www.diagnosoft.com

Fujifilm Medical Systems — 3dimaging.fujimed.com

Pie Medical Imaging — www.piemedical.com

Siemens Healthcare — usa.siemens.com/syngovia

TeraRecon — www.terarecon.com

Vital Images Inc. — www.vitalimages.com

Related Content

Researchers have developed an artificial intelligence (AI)-based brain age prediction model to quantify deviations from a healthy brain-aging trajectory in patients with mild cognitive impairment, according to a study published in Radiology: Artificial Intelligence. The model has the potential to aid in early detection of cognitive impairment at an individual level.

Flowchart showing the framework of the brain age prediction model. A, The imaging data were split into training and test datasets. The training dataset consisted of structural magnetic resonance imaging data from 974 healthy individuals, whereas the test dataset included data from 2 groups, 231 healthy controls and 224 aMCI subjects. B, A Conventional Statistical Parametric Mapping structural preprocessing pipeline was used to generate GMV maps in the MNI space. C, The intensity values from the GMV maps were extracted and concatenated to create a feature matrix that was then cleaned and normalized. D, The best elastic net model was obtained by performing supervised learning on the training dataset. To optimize the hyperparameters, a grid search was performed. E, The test dataset was input into the trained model. An age was predicted for every participant included in the test dataset. The PAD scores were calculated by subtracting the participant's chronological age from his or her predicted age. aMCI = amnestic mild cognitive impairment, GMV = gray matter volume, MNI = Montreal Neurologic Institute, Dartel = Diffeomorphic Anatomic Registrations Through Exponentiated Lie Algebra, PAD = predicted age difference. Chart courtesy of Radiological Society of North America

News | Artificial Intelligence | June 23, 2021
June 23, 2021 — Researchers have developed an...
A cardiac MRI of athletes who had COVID-19 is seven times more effective in detecting inflammation of the heart than symptom-based testing, according to a study led by researchers at The Ohio State University Wexner Medical Center and College of Medicine with 12 other Big Ten programs.

Cardiac Magnetic Resonance Imaging in Athletes With Clinical and Subclinical Myocarditis A-D, Athlete A with subclinical possible myocarditis was asymptomatic with normal electrocardiogram (ECG), echocardiogram, and high-sensitivity troponin findings. A, T2 mapping showing elevated T2 in basal-mid inferolateral wall in short axis view. B, late gadolinium enhancement (LGE) in the basal inferolateral wall in short axis view. C, Postcontrast steady state-free precession (SSFP) images showing contrast uptake in the basal-mid inferolateral wall in short axis view. D, LGE in the inferolateral wall in 3-chamber view. E-H, Athlete B with subclinical probable myocarditis was asymptomatic with normal ECG, normal echocardiogram, and elevated high-sensitivity troponin findings. E, T2 mapping showing elevated T2 in the anteroseptal wall in short axis view. F, LGE in the anteroseptal wall in 3-chamber view. G, T2 mapping showing elevated T2 in the anteroseptal wall in 3-chamber view. F, Postcontrast SSFP image showing pericardial effusion in short axis view. I-K, Athlete C with clinical myocarditis and chest pain, dyspnea, abnormal ECG, normal echocardiogram, and normal troponin findings. I, T2 mapping showing elevated T2 in the lateral wall short axis view. J, Postcontrast SSFP images showing contrast uptake in midlateral wall in short axis view. K, LGE in the epicardial midlateral wall in short axis view. L-N, Athlete D with clinical myocarditis, chest pain, abnormal ECG, echocardiogram, and troponin findings. L, T1 mapping showing elevated native T1 in midlateral wall in short axis view. M, T2 mapping showing elevated T2 in the midlateral wall in short axis view. N, LGE in the epicardial midlateral wall in short axis view. IR indicates inferior right view; IRP, inferior, right, posterior view; PLI, posterior, left, inferior view; SL, superior left view; SLA, superior, left, anterior view. Image courtesy of JAMA Cardiol. Published online May 27, 2021. doi:10.1001/jamacardio.2021.2065

News | Cardiac Imaging | June 15, 2021
June 15, 2021 — A...
Richard Ernst was considered the father of nuclear magnetic resonance imaging (MRI)
News | Magnetic Resonance Imaging (MRI) | June 10, 2021
June 10, 2021 — The Washington Post has reported that Richard R.
According to a pilot study published in ARRS’ American Journal of Roentgenology (AJR), the flexed elbow valgus external rotation (FEVER) view can improve magnetic resonance imaging (MRI) evaluation of the ulnar collateral ligament (UCL) in Major League Baseball (#MLB) pitchers.

(A) Side view of volunteer demonstrating proper positioning for FEVER view; note elevated flexed elbow and sandbags to induce valgus stress. Elbow coil is not included in image.

(B) Coronal fat-saturated proton-density weighted MR image in FEVER view in 20-year-old male pitcher shows normal anterior bundle of UCL (blue arrow) and 2.9 mm UT articular width.

News | Magnetic Resonance Imaging (MRI) | June 04, 2021
A) Ultrasound in 28-year-old woman (B) MRI in 34-year-old woman with suspected PAS disorder. Focal area of placental tissues bulge toward imaginary lines of normal uterine contour (dash lines). Length (L) and depth (D) measurements of placental bulge also demonstrated. p = placenta; b = bladder. Image courtesy of American Roentgen Ray Society (ARRS), American Journal of Roentgenology (AJR)

A) Ultrasound in 28-year-old woman (B) MRI in 34-year-old woman with suspected PAS disorder. Focal area of placental tissues bulge toward imaginary lines of normal uterine contour (dash lines). Length (L) and depth (D) measurements of placental bulge also demonstrated. p = placenta; b = bladder. Image courtesy of American Roentgen Ray Society (ARRS), American Journal of Roentgenology (AJR)

News | Ultrasound Imaging | June 01, 2021
June 1, 2021 — According to an open-access Editor's Choice article in ARRS' ...
Feature | Coronavirus (COVID-19) | May 26, 2021 | By Dave Fornell, Editor
May 26, 2021 — There are increasing reports of persistent symptoms after a patient recovers from...
The U.S. Food and Drug Administration (FDA) issued this final guidance: Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment.

Image courtesy of Philips

News | Magnetic Resonance Imaging (MRI) | May 21, 2021
May 21, 2021 — The U.S.