News | February 17, 2015

Simple Ultrasound Measure Can Diagnose Postoperative Urinary Retention

Test provides quick, inexpensive alternative for assessing common complication

ultrasound systems, postoperative urinary retention, study

February 17, 2015 — In patients who don't resume normal urination after surgery, a simple ultrasound test can accurately diagnose the common problem of postoperative urinary retention (POUR), reports a study in Anesthesia & Analgesia.

Using ultrasound to measure bladder diameter provides a quick and inexpensive test for POUR, according to the new research by Aurélien Daurat, M.D., and colleagues of Lapeyronie University Hospital, Montpelier, France. The researchers believe their simplified approach may obviate the need for costly automated devices for measuring bladder volume.

Daurat and coauthors evaluated their simplified approach to ultrasound bladder measurement in 100 patients who were considered at risk of POUR because they were unable to void (urinate) after orthopedic surgery. Postoperative urinary retention is a common side effect after surgery and general anesthesia. If the bladder isn't emptied, POUR can prolong the patient's hospital stay and lead to potentially serious complications.

In the recovery room, all patients underwent a single ultrasound measurement of bladder diameter in the transverse dimension. These measures were obtained by nurses using a pocket-sized portable ultrasound device.

All 100 patients then underwent measurement of bladder volume using a special automated device. About half of the patients underwent placement of a catheter to drain the bladder, which allowed measurement of the actual volume of urine. The results were compared to evaluate the ultrasound's ability test to diagnose POUR—defined as an automated measurement of 600 milliliters and/or the need for catheter placement.

The average bladder diameter was about 11 cm in patients with POUR, compared with 8 to 9 cm in those without POUR. The ultrasound-measured diameter was strongly correlated with the automated bladder volume measurement or the actual urine volume.

Ultrasound bladder measurement proved to be an accurate diagnostic test for POUR. If the bladder diameter was 9.7 cm or less, the patient could be safely discharged. If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The ultrasound test would be considered inconclusive only for patients in the "grey zone" between 9.7 and 10.7 cm.

The researchers note that the test can be efficiently performed by nurses using a widely available portable ultrasound device—an important advantage over approaches using more complex measurements or specialized equipment.

For more information: www.journals.lww.com/anesthesia-analgesia

Related Content

Technology | Ultrasound Imaging | August 18, 2017
August 18, 2017 — SuperSonic Imagine recently introduced the newest version of its premium...
Pentax Medical Launches New Slim Linear Ultrasound Endoscope
Technology | Endoscopes | August 17, 2017
Pentax Medical Co. announced the U.S. launch of the Slim Linear Ultrasound Endoscope (EG-3270UK), the company's newest...
Houston Methodist Hospital Enters Multi-Year Technology and Research Agreement With Siemens Healthineers
News | Imaging | August 17, 2017
Houston Methodist Hospital and Siemens Healthineers have entered into a multi-year agreement to bring cutting-edge...
Clarius Wireless Ultrasound Scanners Now Available With Advanced Features
News | Ultrasound Imaging | August 09, 2017
Clarius Mobile Health has released advanced features and options for its wireless handheld ultrasound scanner for...
Oregon Tech Partners with Mindray for High-Tech Ultrasound Education
News | Ultrasound Imaging | August 04, 2017
To better prepare its ultrasound students to compete and thrive in the evolving healthcare environment, Oregon...
Carestream Shows Touch Prime Systems at Society for Vascular Ultrasound Conference
News | Ultrasound Imaging | August 03, 2017
Carestream will showcase its Carestream Touch Prime and Touch Prime XE Ultrasound Systems at the Society for Vascular...
3-D Vascular Ultrasound Quantifies Plaque Burden to Estimate Cardiovascular Risk
News | Cardiovascular Ultrasound | July 20, 2017
In a large, first-of-its-kind population, researchers found an experimental technique known as three-dimensional...
Floyd Medical Center Acquires Quartet of Toshiba Cardiac Ultrasound Systems
News | Cardiovascular Ultrasound | July 19, 2017
Floyd Medical Center in Rome, Ga., recently installed three new Aplio 500 Platinum CV ultrasound systems from Toshiba...
Synergy Radiology Associates Employs UroNav Fusion Biopsy System for Better Prostate Cancer Diagnosis
News | Biopsy Systems | July 17, 2017
Radiologists from Synergy Radiology Associates (SRA) in Houston are using the power of 3-D medical imaging and...
Overlay Init