News | February 17, 2015

Simple Ultrasound Measure Can Diagnose Postoperative Urinary Retention

Test provides quick, inexpensive alternative for assessing common complication

ultrasound systems, postoperative urinary retention, study

February 17, 2015 — In patients who don't resume normal urination after surgery, a simple ultrasound test can accurately diagnose the common problem of postoperative urinary retention (POUR), reports a study in Anesthesia & Analgesia.

Using ultrasound to measure bladder diameter provides a quick and inexpensive test for POUR, according to the new research by Aurélien Daurat, M.D., and colleagues of Lapeyronie University Hospital, Montpelier, France. The researchers believe their simplified approach may obviate the need for costly automated devices for measuring bladder volume.

Daurat and coauthors evaluated their simplified approach to ultrasound bladder measurement in 100 patients who were considered at risk of POUR because they were unable to void (urinate) after orthopedic surgery. Postoperative urinary retention is a common side effect after surgery and general anesthesia. If the bladder isn't emptied, POUR can prolong the patient's hospital stay and lead to potentially serious complications.

In the recovery room, all patients underwent a single ultrasound measurement of bladder diameter in the transverse dimension. These measures were obtained by nurses using a pocket-sized portable ultrasound device.

All 100 patients then underwent measurement of bladder volume using a special automated device. About half of the patients underwent placement of a catheter to drain the bladder, which allowed measurement of the actual volume of urine. The results were compared to evaluate the ultrasound's ability test to diagnose POUR—defined as an automated measurement of 600 milliliters and/or the need for catheter placement.

The average bladder diameter was about 11 cm in patients with POUR, compared with 8 to 9 cm in those without POUR. The ultrasound-measured diameter was strongly correlated with the automated bladder volume measurement or the actual urine volume.

Ultrasound bladder measurement proved to be an accurate diagnostic test for POUR. If the bladder diameter was 9.7 cm or less, the patient could be safely discharged. If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The ultrasound test would be considered inconclusive only for patients in the "grey zone" between 9.7 and 10.7 cm.

The researchers note that the test can be efficiently performed by nurses using a widely available portable ultrasound device—an important advantage over approaches using more complex measurements or specialized equipment.

For more information: www.journals.lww.com/anesthesia-analgesia

Related Content

Technology | Focused Ultrasound Therapy | June 19, 2018
EDAP TMS SA has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for its Focal One device for...
Epsilon Imaging Demonstrates Strain Imaging Integration for Echo Programs at ASE 2018
News | Cardiovascular Ultrasound | June 19, 2018
Clinical practice, along with guidelines and research, have shown that speckle tracking strain imaging can improve...
FDA Clears Bay Labs' EchoMD AutoEF Software for AI Echo Analysis
Technology | Cardiovascular Ultrasound | June 19, 2018
Cardiovascular imaging artificial intelligence (AI) company Bay Labs announced its EchoMD AutoEF software received 510(...
Hitachi Medical Systems Europe Named Imaging Supplier for London Prostate Cancer Program
News | Prostate Cancer | June 14, 2018
Hitachi Medical Systems Europe has been awarded the contract to supply six ultrasound systems as part of the RAPID...
How AI and Deep Learning Will Enable Cancer Diagnosis Via Ultrasound

The red outline shows the manually segmented boundary of a carcinoma, while the deep learning-predicted boundaries are shown in blue, green and cyan. Copyright 2018 Kumar et al. under Creative Commons Attribution License.

News | Ultrasound Imaging | June 12, 2018 | Tony Kontzer
June 12, 2018 — Viksit Kumar didn’t know his mother had...
Olympus and Hitachi Healthcare Americas Introduce Arietta 850
News | Ultrasound Imaging | June 04, 2018
Olympus, a global technology leader in designing and delivering innovative solutions for medical and surgical procedu
New Ultrasound Guidelines Reliably Identify Children Who Should be Biopsied for Thyroid Cancer

Image courtesy of Loyola Medicine

News | Pediatric Imaging | May 29, 2018
A Loyola Medicine study has found that new ultrasound guidelines can reliably identify pediatric patients who should be...
Samsung Receives FDA Clearance for Premium Ultrasound System RS85
Technology | Ultrasound Imaging | May 07, 2018
NeuroLogica, a subsidiary of Samsung Electronics Co. Ltd., announced the Samsung RS85 ultrasound system has received U....
3D-4D ultrasound of a fetus imaged with a GE Volusion E10 system. It shows the yoke sac. This is a baby ultrasound, also referred to as fetal ultrasound or prenatal ultrasound.

3D-4D ultrasound of a fetus imaged with a GE Volusion E10 system. It shows the yoke sac.

Feature | Ultrasound Women's Health | May 07, 2018
Below is a collection of prenatal ultrasound images from the ITN archive.
Esaote Change of Ownership Completed
News | Ultrasound Imaging | April 30, 2018
The acquisition of biomedical equipment company Esaote SpA’s share capital was completed on April 19, the company...
Overlay Init