Feature | January 12, 2012

Experts Offer Pointers for Optimizing Radiation Dose in Pediatric CT

Experts Offer Pointers for Optimizing Radiation Dose in Pediatric CT

January 12, 2012 — An article in the January issue of the Journal of the American College of Radiology summarizes methods for radiation dose optimization in pediatric computed tomography (CT) scans. Approximately seven to eight million CT examinations are performed for various pediatric clinical indications per year in the United States.

Justification of clinical indication is the most important aspect of reducing radiation dose with CT scanning. A substantial number of pediatric CT scans lack appropriate justification or can be replaced with other imaging modalities with lower or no ionizing radiation, such as radiography, ultrasonography and magnetic resonance imaging (MRI), which can provide similar diagnostic information for some clinical conditions. 

“When not clinically indicated, not performing a CT examination is certainly the best radiation dose reduction strategy. However, when a CT scan is indicated, there are steps that can be taken to optimize the dose that children receive. It’s important that all imaging providers take these steps as indicated,” said Mannudeep K. Kalra, M.D., author of the article. 

Investigators from Massachusetts General Hospital, Harvard Medical School, in Boston, and Johns Hopkins University in Baltimore, reviewed practical strategies for reducing radiation dose associated with pediatric CT examinations. “Radiation dose reduction in children starts with the optimization of pediatric CT protocols,” said Mahadevappa Mahesh, MS, Ph.D., author of the article. “CT protocols should be strictly optimized on the basis of body size, body region, clinical indication and the availability of prior imaging.”

Additional steps include using a lower tube current and voltage, restricting the scan length to include only the region of interest and using new techniques of image post-processing and reconstruction.   

“Children are more sensitive to radiation-induced risks and need special attention. Therefore, while designing CT protocols, it is crucial to keep clinical indications, weight and prior available imaging in mind to optimize radiation dose,” said Mahesh.

 For more information: www.jacr.org, www.imagewisely.org, www.imagegently.org

Related Content

Doctor-Patient Discussions Neglect Potential Harms of Lung Cancer Screening
News | Lung Cancer | August 15, 2018
August 15, 2018 — Although national guidelines advise doctors to discuss the benefits and harms of...
Guerbet Partners With Imalogix on Dose Optimization With Artificial Intelligence
News | Radiation Dose Management | August 14, 2018
August 14, 2018 — Guerbet LLC USA announced a commercial partnership with Imalogix, a provider of...
ACR LI-RADS Steering Committee Releases New Version of CT/MRI LI-RADS
News | Clinical Decision Support | August 13, 2018
August 13, 2018 — The American College of Radiology Liver Imaging Reporting and Data System (LI-RADS) steering commit
Aidoc Receives FDA Clearance for AI Detection of Acute Intracranial Hemorrhage
Technology | Clinical Decision Support | August 08, 2018
Aidoc announced that it was granted U.S. Food and Drug Administration (FDA) clearance for the first product of its...
Cardiac Imaging Reveals Roots of Preeclampsia Damage in Pregnant Women
News | Women's Health | August 07, 2018
Johns Hopkins researchers say a heart imaging study of scores of pregnant women with the most severe and dangerous form...
Cardiac Monitoring a Higher Priority for High-Risk Breast Cancer Patients
News | Cardio-oncology | August 07, 2018
August 7, 2018 — While heart failure is an uncommon complication of...
Imalogix Brings Fluoroscopy Capabilities to Radiation Dose Management Platform
Technology | Radiographic Fluoroscopy (RF) | August 06, 2018
Imalogix, a provider of artificial intelligence (AI) process and workflow solutions, announced the availability of the...
Hologic Acquires Digital Specimen Radiography Company Faxitron Bioptics

VisionCT 3-D breast specimen-designated computed tomography (CT) system. Image courtesy of Faxitron Bioptics.

News | Breast Imaging | July 31, 2018
Hologic Inc. announced it has completed the acquisition of Faxitron Bioptics, a privately-held leader in digital...
Varian Showcases Advanced Cancer Care Solutions at AAPM 2018
News | Radiation Therapy | July 27, 2018
Varian announced it will be showcasing its advanced cancer care solutions, including a new version of the Eclipse...
Overlay Init