News | Magnetic Resonance Imaging (MRI) | July 13, 2021

Finding prompts researchers, clinicians to consider this impact in future research and clinical treatment of brain diseases

In a mouse model study of MRI-guided focused ultrasound-induced blood-brain barrier (BBB) opening at MRI field strengths ranging from ­approximately 0 T (outside the magnetic field) to 4.7 T, the static magnetic field dampened the detected microbubble cavitation signal and decreased the BBB opening volum

In a mouse model study of MRI-guided focused ultrasound-induced blood-brain barrier (BBB) opening at MRI field strengths ranging from ­approximately 0 T (outside the magnetic field) to 4.7 T, the static magnetic field dampened the detected microbubble cavitation signal and decreased the BBB opening volume. Image courtesy of Washington University in St. Louis


July 13, 2021 — MRI-guided focused ultrasound combined with microbubbles can open the blood-brain barrier (BBB) and allow therapeutic drugs to reach the diseased brain location under the guidance of MRI. It is a promising technique that has been shown safe in patients with various brain diseases, such as Alzheimer's diseases, Parkinson's disease, ALS and glioblastoma. While MRI has been commonly used for treatment guidance and assessment in preclinical research and clinical studies, until now, researchers did not know the impact of the static magnetic field generated by the MRI scanner on the BBB opening size and drug delivery efficiency.

In new research published in Radiology, Hong Chen and her lab at Washington University in St. Louis have found for the first time that the magnetic field of the MRI scanner decreased the BBB opening volume by 3.3-fold to 11.7-fold, depending on the strength of the magnetic field, in a mouse model.

Chen, associate professor of biomedical engineering in the McKelvey School of Engineering and of radiation oncology in the School of Medicine, and her lab conducted the study on 30 mice divided into four groups. After the mice received the injection of the microbubbles, three groups received focused-ultrasound sonication at different strengths of the magnetic field: 1.5 T (teslas), 3 T and 4.7 T, while one group never entered the magnetic field.

They found that the activity of the microbubble cavitation, or the expansion, contraction and collapse of the microbubbles, decreased by 2.1 decibels at 1.5 T; 2.9 decibels at 3 T; and 3 decibels at 4.7 T, compared with those that had received the dose outside of the magnetic field. In addition, the magnetic field decreased the BBB opening volume by 3.3-fold at 1.5 T; 4.4-fold at 3 T; and 11.7-fold at 4.7 T. None of the mice showed any tissue damage from the procedure.

Following focused-ultrasound sonication, the team injected a model drug, Evans blue, to test whether the static magnetic field affects trans-BBB drug delivery efficiency. The images showed that the fluorescence intensity of the Evans blue was lower in mice that received the treatment in one of the three strengths of magnetic fields compared with mice treated outside the magnetic field. The Evans blue trans-BBB delivery was decreased by 1.4-fold at1.5 T, 1.6-fold at 3.0 T and 1.9-fold at 4.7 T when compared with those treated outside of the magnetic field.

"The dampening effect of the magnetic field on the microbubble is likely caused by the loss of bubble kinetic energy due to the Lorentz force acting on the moving charged lipid molecules on the microbubble shell and dipolar water molecules surrounding the microbubbles," said Yaoheng (Mack) Yang, a doctoral student in Chen's lab and the lead author of the study.

"Findings from this study suggest that the impact of the magnetic field needs to be considered in the clinical applications of focused ultrasound in brain drug delivery," Chen said.

In addition to brain drug delivery, cavitation is also the fundamental physical mechanism for several other therapeutic techniques, such as histotripsy, the use of cavitation to mechanically destroy regions of tissue, and sonothrombolysis, a therapy used after acute ischemic stroke. The dampening effect induced by the magnetic field on cavitation is expected to affect the treatment outcomes of other cavitation-mediated techniques when MRI-guided focused-ultrasound systems are used.

For more information: www.wustl.edu


Related Content

News | Ultrasound Women's Health

Sept. 3, 2026 — Royal Philips has introduced the eV14-2v transvaginal transducer, expanding its obstetrics and ...

Time September 04, 2026
arrow
News | Radiology Business

August 18, 2026 – NewVue, a provider of cloud-native software that unifies how radiologists work while improving ...

Time August 25, 2026
arrow
News | Breast Imaging

Aug. 20, 2026 — Candelis, Inc. has announced a collaboration with GE HealthCare to support the distribution of Candelis ...

Time August 24, 2026
arrow
News | Radiology Imaging

Aug. 13, 2026 — Epic's new Care Everywhere Diagnostic Image Exchange allows health systems using Epic to share ...

Time August 21, 2026
arrow
News | Cardiac Imaging

Aug. 20, 2026 – The novel, radiopaque, polymer-based embolic coil from Embolization, Inc. has now surpassed 125 implants ...

Time August 20, 2026
arrow
News | Ultrasound Imaging

Aug. 13, 2026 — The Focused Ultrasound Foundation and Bracco Imaging have announced a partnership to facilitate access ...

Time August 19, 2026
arrow
News | Clinical Trials

Aug.12, 2026 — Mendaera Inc. has announced results from a peer-reviewed study showing that its FDA-cleared Focalist ...

Time August 17, 2026
arrow
Feature | Artificial Intelligence | Madhu Jahagirdar

Radiologists spend much of their day moving between different systems: One application to review images. Another to ...

Time August 17, 2026
arrow
News | X-Ray

Aug. 10, 2026 — Teledyne Technologies Inc. and Varex Imaging Corp. have jointly announced that they have entered into a ...

Time August 14, 2026
arrow
News | FDA

Aug. 1, 2026 — Candelis recently announced that the U.S. Food and Drug Administration (FDA) has granted 510(k) clearance ...

Time August 13, 2026
arrow
Subscribe Now