News | PET Imaging | March 03, 2017

New PET Radiotracer Identifies Inflammation in Life-Threatening Atherosclerosis

Unlike FDG, gallium-68 pentixafor binds specifically to inflammatory cells, does not require six-hour pre-exam fast

PET imaging, atherosclerotic plaque, inflammation, Ga-68-pentixafor, Technishe Universitat Munchen, Germany

Note the high uptake of Ga-68-pentixafor on multi-planar reconstructions in the organs expressing CXCR4 such as the spleen (red arrows) and adrenal glands (yellow arrows), which was nearly completely blocked by the pre-injection of AMD 3100, a potent CXCR4 inhibitor. Strong accumulation of Ga-68-pentixafor was also found in the kidneys (asterisks) reflecting the renal clearance of the tracer. In addition, high, focal activities were detected in the abdominal aorta (red arrowheads) and right carotid artery (orange arrowheads) of atherosclerotic rabbits, whereas no significant signal could be detected in the non-injured left carotid artery (white arrowheads) of atherosclerotic and control rabbits, as well as in the abdominal aorta and right carotid artery of control rabbits. Furthermore, focal activities detected with PET in atherosclerotic plaques of the abdominal aorta and the right carotid artery decreased significantly when the same rabbit was re-imaged after blocking CXCR4 receptors. Image courtesy of Fabien Hyafil, M.D., Ph.D., Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany

March 3, 2017 — In the featured article of the March 2017 issue of The Journal of Nuclear Medicine, researchers demonstrate that a new positron emission tomography (PET) radiotracer, gallium-68 (Ga-68)-pentixafor, can quickly and non-invasively identify life-threatening atherosclerotic plaques. The tracer binds to the CXCR4 receptor on inflammatory cells present in atherosclerotic plaques — making it possible to find and treat atherosclerosis early.

Atherosclerosis represents the main cause of heart attack and stroke. According to the Centers for Disease Control and Prevention, every year about 735,000 Americans have a heart attack and 800,000 have a stroke. Stroke kills more than 130,000 Americans a year, and about 610,000 die from cardiovascular disease.

Atherosclerosis develops over decades with the progressive accumulation of lipids, inflammatory cells and connective tissue within the inner layer of arterial walls leading to a local thickening of the vascular wall called atherosclerotic plaque. These plaques can remain asymptomatic for years, but an inflammatory reaction can develop causing the plaques to rupture and stimulate clot formation. If a clot completely blocks an artery, no oxygen can reach the downstream tissue, resulting in the sudden development of heart attack or stroke. The challenge is to identify patients with these dangerous atherosclerotic plaques before a heart attack or stroke occurs.

Currently, there is no clinically available non-invasive imaging technique specifically to detect inflammation. F-18-fluorodeoxyglucose (FDG)-PET is being used but has important limitations. It is taken up by many cells other than inflammatory cells, including cardiac and brain cells. The strong signal present in the organs next to the arteries limits the precise analysis of the radiotracer uptake in atherosclerotic plaques. In addition, patients need to fast at least six hours before FDG injection to avoid interferences with blood sugar and muscular uptake of the tracer that impair image quality.

"Ga-68-pentixafor binds more specifically to inflammatory cells than FDG and does not require the patient to fast for six hours before imaging," explained Fabien Hyafil, M.D., Ph.D., of Klinikum Rechts der Isar, Munich, Germany, and Bichat University Hospital, Assistance Publique, Hôpitaux de Paris, Paris, France.

In the study, the specific binding of Ga-68-pentixafor to inflammatory cells located in atherosclerotic plaques was first validated in an animal model. Seven atherosclerotic rabbits and five controls were imaged on a PET-MRI (magnetic resonance imaging) system after injection of the tracer. Resulting images clearly showed inflammation in plaques in the abdominal aorta and right carotid artery of the atherosclerotic rabbits. The researchers also confirmed with a small number of human patients that the radiotracer detected atherosclerotic plaques located in their carotid arteries.

Hyafil emphasized, "This new radiotracer will strongly facilitate the imaging of inflammation in atherosclerotic plaques with PET and hopefully support the early detection and treatment of atherosclerosis, thus preventing heart attack or stroke."

This work was supported by the European Research Council Executive Agency through a Multimodal Molecular Imaging Advanced Research Grant (Grant number 294582), the Deutsche Forschungsgemeinschaft (SFB 824-B5 and SFB 1123-A1), and Deutsches Zentrum für Herz-Kreislauf Forschung through a high-risk, high-volume grant.

For more information: www.jnm.snmjournals.org

References

Hyafil, F., Pelisek, J., Laitinen, I., Schottelius, M., et al. "Imaging the Cytokine Receptor CXCR4 in Atherosclerotic Plaques with the Radiotracer Ga-68-Pentixafor for PET," Journal of Nuclear Medicine. Published online Oct. 27, 2016. DOI: 10.2967/jnumed.116.179663

Related Content

Partial Breast Irradiation Effective, Convenient Treatment Option for Low-Risk Breast Cancer
News | Radiation Therapy | May 20, 2019
Partial breast irradiation produces similar long-term survival rates and risk for recurrence compared with whole breast...
AI Detects Unsuspected Lung Cancer in Radiology Reports, Augments Clinical Follow-up
News | Artificial Intelligence | May 20, 2019
Digital Reasoning announced results from its automated radiology report analytics research. In a series of experiments...
Baylor Scott White Heart Hospital Siemens Flash CT system used for dedicated cardiac CT scans, CCTA, CTA.
360 Photos | CT Angiography (CTA) | May 20, 2019
This is a 360 degree photo of a Siemens Somatom Force 64-slice, dual-source computed tomography (CT) system installed
360 Photos | Cardiac Imaging | May 20, 2019
A 360 degree photo view of a Siemens Healthineers digital radiography (DR) room install and mobile Carestream DRX mob
360 Photos | Angiography | May 17, 2019
This is a view inside one of the 11 cath labs at ...
360 Photos | Magnetic Resonance Imaging (MRI) | May 17, 2019
This is a dedicated cardiac Siemens 1.5T MRI system installed at the Baylor Scott White Heart Hospital in Dallas.
New Study Evaluates Head CT Examinations and Patient Complexity
News | Neuro Imaging | May 17, 2019
Computed tomography (CT) of the head uses special X-ray equipment to help assess head injuries, dizziness and other...
New Phase 2B Trial Exploring Target-Specific Myocardial Ischemia Imaging Agent
News | Radiopharmaceuticals and Tracers | May 17, 2019
Biopharmaceutical company CellPoint plans to begin patient recruitment for its Phase 2b cardiovascular imaging study in...
Managing Architectural Distortion on Mammography Based on MR Enhancement
News | Mammography | May 15, 2019
High negative predictive values (NPV) in mammography architectural distortion (AD) without ultrasonographic (US)...
Icon Launches New Clinical Trial Patient Engagement Platform
Technology | Patient Engagement | May 14, 2019
Icon plc announced the release of its web-based clinical trial patient engagement platform, to provide patients with...