News | Computed Tomography (CT) | August 15, 2022

Combo of deep-learning reconstruction and subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA 

57-year-old man who underwent coronary CTA using two-breath-hold subtraction technique to assess patency of coronary artery stent.

A. Conventional HIR image and B. conventional DLR image show blurred appearance of proximal aspect of stent (arrow). C. Subtraction HIR image and D. subtraction DLR image show discrete region of hypoattenuation at proximal aspect of stent (arrow). Both readers provided a diagnosis of in-stent restenosis only for subtraction HIR and subtraction DLR. Diagnostic confidence score for the four methods for reader 1 was 2, 2, 3, and 4, respectively, and for reader 2 was 1, 2, 3, and 3, respectively. Patient subsequently underwent invasive catheter angiography. Fluoroscopic imagines obtained (E) before and (F) after contrast media injection demonstrate in-stent restenosis of proximal aspect of stent (arrow). Image courtesy of ARRS and AJR 


August 15, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), the combination of deep-learning reconstruction (DLR) and a subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA. 

Noting that these findings could guide patient selection for invasive coronary stent evaluation, combining DLR with a two-breath-hold subtraction technique “may help overcome challenges related to stent-related blooming artifact,” added corresponding author Yi-Ning Wang from the State Key Laboratory of Complex Severe and Rare Diseases at China’s Peking Union Medical College Hospital. 

Between March 2020 and August 2021, Wang and team studied 30 patients (22 men, 8 women; mean age, 63.6 years) with a total of 59 coronary stents who underwent coronary CTA using the two-breath-hold technique (i.e., noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for hybrid iterative reconstruction (HIR) and DLR, while maximum visible in-stent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥50% stenosis). 

Ultimately, coronary CTA using DLR and subtraction technique—with a combined (conventional and subtraction images) interpretation—yielded PPV, NPV, and accuracy for in-stent restenosis for reader 1 of 73.3%, 93.2%, and 88.1%, and for reader 2 of 75.0%, 84.3%, and 83.1%, respectively. 

Acknowledging that the two-breath-hold subtraction technique requires an additional noncontrast acquisition (and thus a higher radiation dose), “DLR allows a reduction in radiation exposure, while improving image quality,” the authors of this AJR article pointed out

For more information: www.arrs.org 


Related Content

News | Magnetic Resonance Imaging (MRI)

February 1, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), MRI ...

Time February 01, 2023
arrow
News | Computed Tomography (CT)

January 30, 2023 — Photon-counting detector CT reduces the amount of contrast needed for CT angiography (CTA) while ...

Time January 30, 2023
arrow
News | Radiology Imaging

January 23, 2023 — Canon Medical Systems has released a new eBook featuring its new medical imaging roadshow. This new ...

Time January 23, 2023
arrow
Videos | Cardiac Imaging

Artificial intelligence and general consolidation were two top cardiology trends at RSNA22. ITN/DAIC spoke with Val ...

Time January 23, 2023
arrow
News | Artificial Intelligence

January 20, 2023 — Artificial intelligence (AI) can reconstruct coarsely-sampled, rapid magnetic resonance imaging (MRI) ...

Time January 20, 2023
arrow
News | RSNA

January 18, 2023 — Artificial intelligence (AI) may help improve care for patients who show up at the hospital with ...

Time January 18, 2023
arrow
News | Radiology Business

January 18, 2023 — Addressing the growing demand for medical imaging and a shortage of radiologists, Bayer announced the ...

Time January 18, 2023
arrow
Feature | Cardiac Imaging | By Christine Book

According to the U.S. Centers for Disease Control and Prevention (CDC), one person dies every 37 seconds in the United ...

Time January 18, 2023
arrow
Feature | RSNA | By Melinda Taschetta-Millane

The Radiological Society of North America’s (RSNA) 108th Scientific Assembly and Annual Meeting (RSNA22) took place at ...

Time January 16, 2023
arrow
News | Cardiac Imaging

January 13, 2023 — Nuclear stress testing performed with single-photon emission computed tomography (SPECT) is the most ...

Time January 13, 2023