News | Computed Tomography (CT) | August 15, 2022

Combo of deep-learning reconstruction and subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA 

57-year-old man who underwent coronary CTA using two-breath-hold subtraction technique to assess patency of coronary artery stent.

A. Conventional HIR image and B. conventional DLR image show blurred appearance of proximal aspect of stent (arrow). C. Subtraction HIR image and D. subtraction DLR image show discrete region of hypoattenuation at proximal aspect of stent (arrow). Both readers provided a diagnosis of in-stent restenosis only for subtraction HIR and subtraction DLR. Diagnostic confidence score for the four methods for reader 1 was 2, 2, 3, and 4, respectively, and for reader 2 was 1, 2, 3, and 3, respectively. Patient subsequently underwent invasive catheter angiography. Fluoroscopic imagines obtained (E) before and (F) after contrast media injection demonstrate in-stent restenosis of proximal aspect of stent (arrow). Image courtesy of ARRS and AJR 


August 15, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), the combination of deep-learning reconstruction (DLR) and a subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA. 

Noting that these findings could guide patient selection for invasive coronary stent evaluation, combining DLR with a two-breath-hold subtraction technique “may help overcome challenges related to stent-related blooming artifact,” added corresponding author Yi-Ning Wang from the State Key Laboratory of Complex Severe and Rare Diseases at China’s Peking Union Medical College Hospital. 

Between March 2020 and August 2021, Wang and team studied 30 patients (22 men, 8 women; mean age, 63.6 years) with a total of 59 coronary stents who underwent coronary CTA using the two-breath-hold technique (i.e., noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for hybrid iterative reconstruction (HIR) and DLR, while maximum visible in-stent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥50% stenosis). 

Ultimately, coronary CTA using DLR and subtraction technique—with a combined (conventional and subtraction images) interpretation—yielded PPV, NPV, and accuracy for in-stent restenosis for reader 1 of 73.3%, 93.2%, and 88.1%, and for reader 2 of 75.0%, 84.3%, and 83.1%, respectively. 

Acknowledging that the two-breath-hold subtraction technique requires an additional noncontrast acquisition (and thus a higher radiation dose), “DLR allows a reduction in radiation exposure, while improving image quality,” the authors of this AJR article pointed out

For more information: www.arrs.org 


Related Content

News | Radiopharmaceuticals and Tracers

Aug. 30, 2026 — Bayer has announced the presentation of first detailed results from the Phase III REVEAL study, an ...

Time September 02, 2026
arrow
News | Radiology Imaging

Aug. 13, 2026 — Epic's new Care Everywhere Diagnostic Image Exchange allows health systems using Epic to share ...

Time August 21, 2026
arrow
News | Cardiac Imaging

Aug. 20, 2026 – The novel, radiopaque, polymer-based embolic coil from Embolization, Inc. has now surpassed 125 implants ...

Time August 20, 2026
arrow
News | Breast Imaging

Aug. 13, 2026 – Perimeter Medical Imaging AI recently announced that Intermountain Health, the largest nonprofit health ...

Time August 14, 2026
arrow
News | Lung Imaging

Aug. 11, 2026 — Noah Medical has launched the Galaxy II software, the next evolution of its robotic-assisted ...

Time August 10, 2026
arrow
News | Radiology Business

Aug. 4, 2026 — Canon Medical Systems USA (CMSU) has appointed Tsuneo "Neo" Imai as president and chief executive officer ...

Time August 10, 2026
arrow
News | Computed Tomography (CT)

July 23, 2026 — HOPPR has introduced HOPPR EF Chest CT Narrative Model, a foundation model that processes 3D chest CT ...

Time July 27, 2026
arrow
News | Point-of-Care Ultrasound (POCUS)

July 21, 2026 — Fujifilm Sonosite has launched Sonosite iLOOK, a compact ultrasound solution designed specifically for ...

Time July 22, 2026
arrow
News | Radiology Imaging

June 15, 2026 — Lead Glass Pro, a supplier of radiation shielding products, has expanded its turnkey installation ...

Time June 18, 2026
arrow
News | Nuclear Imaging

June 1, 2026 — At the 2026 Society of Nuclear Medicine and Molecular Imaging (SNMMI) annual meeting, GE HealthCare will ...

Time June 02, 2026
arrow
Subscribe Now