News | Nuclear Imaging | July 19, 2016

ASNC/SNMMI Release Updated Procedure Standard for PET Nuclear Cardiology Scans

ASNC, SNMMI, PET standard, Pet cardiac imaging, PET nuclear imaging, perfusion imaging

An example of a cardiac PET-CT imaging, should a color coded image of the left ventricle to help assess myocardial perfusion to detect ischemia using a Siemens scanner.

July 19, 2016 - An updated joint American Society of Nuclear Cardiology (ASNC) imaging guidelines and Society of Nuclear Medicine and Molecular Imaging (SNMMI) procedure standard for positron emission tomography (PET) nuclear cardiology procedures has been published in the 2016 September issue of the Journal of Nuclear Cardiology.[1] It addresses the areas of PET myocardial perfusion and metabolism clinical imaging. The new guideline provides imaging guidelines for physicians and technologists who are qualified to practice nuclear cardiology. 

Read more on PET vs. SPECT imaging technologies.

The guidelines document is the outcome of close collaboration between SNMMI and ASNC and among experts in the field from both organizations, which has been subjected to extensive review, requiring the approval of several committees from both organizations, and ultimately the endorsement of both SNMMI and ASNC Board of Directors.

To assure quality health care, the Centers for Medicare & Medicaid Services (CMS) has recently implemented quality initiatives that include: effective, safe, efficient, patient-centered, equitable, and timely care. The new guidelines state that the superior imaging properties of PET meet some of the CMS quality goals. Benefits of PET include higher myocardial count density at a shorter image acquisition time than SPECT and less scatter of activity from adjacent sub-diaphragmatic visceral structures into the myocardial region. PET myocardial perfusion imaging provides high diagnostic accuracy (effective), low radiation exposure (safe), short image-acquisition times (efficient), and accommodates ill or higher-risk patients, as well as those with large body habitus (patient-centered), providing equitable and timely care, the guidelines state.

While SPECT assessment of stress and rest myocardial perfusion have been firmly established as important diagnostic and prognostic tools for the evaluation of myocardial ischemia and prior infarction, the interpretation of SPECT myocardial perfusion imaging studies has been primarily qualitative or semi quantitative in nature, the guidelines state. The detrimental effects of soft tissue attenuation, which tends to degrade image quality and increase interpretive errors, have long been recognized with SPECT. The societies consensus is that PET provides better spatial and temporal resolution and allows reliable and accurate soft tissue attenuation correction when compared to SPECT, particularly in patients who are obese or have large body habitus. In concert with tracer-kinetic modeling and robust attenuation correction, PET permits the assessment of regional myocardial blood flow (MBF) of the left ventricle in absolute terms (milliliters per gram per minute). 

The guidelines and PET standard article also outlines progress in PET imaging for myocardial perfusion in terms of absolute hyperemic blood flow and flow reserve. Another section explains the progress in PET imaging of glucose metabolism and its use to image cardiac device infections and sarcoidosis.

To access the full article, visit http://link.springer.com/article/10.1007/s12350-016-0522-3

 

Read an overview of the current PET technology

Reference:

1. Dilsizian, V., Bacharach, S.L., Beanlands, R.S. et al. “ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures.” J. Nucl. Cardiol. (2016). doi:10.1007/s12350-016-0522-3

Related Content

MIM Software Inc. Receives FDA 510(k) Clearance for Molecular Radiotherapy Dosimetry
Technology | Nuclear Imaging | January 16, 2019
MIM Software Inc. received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for molecular radiotherapy...
SCCT Releases New Guideline for CT Use During TAVR
News | Computed Tomography (CT) | January 08, 2019
The Society of Cardiovascular Computed Tomography (SCCT) has released a new expert consensus document for computed...
Breast Cancer Patients Have Less Heart Damage With Heart Drug and Trastuzumab
News | Cardio-oncology | January 03, 2019
Breast cancer patients who take a heart drug at the same time as trastuzumab have less heart damage, according to a...
Videos | SPECT-CT | December 12, 2018
This is a walk around of the new Spectrum Dynamics Veriton SPECT-CT nuclear imaging system introduced at the 2018 ...
Hitachi Medical Systems Europe Introduces Third-Generation Intelligent Vector Flow Mapping
News | Cardiovascular Ultrasound | December 07, 2018
Hitachi Medical Systems Europe introduced what it calls the next level of intelligent Vector Flow Mapping (iVFM) at...
Spectrum Dynamics Sues GE for Theft, Misappropriation of Trade Secrets and Unfair Competition
News | SPECT Imaging | December 06, 2018
Single-photon emission computed tomography (SPECT) cardiac imaging company Spectrum Dynamics filed a lawsuit Dec. 6,...
Subtle Medical Receives FDA Clearance, CE Mark for SubtlePET
Technology | PET Imaging | December 05, 2018
Subtle Medical announced 510(k) clearance from the U.S. Food and Drug Administration (FDA) to market SubtlePET. Subtle...
Mirada Medical Joins U.K. Consortium Exploring Healthcare AI
News | Artificial Intelligence | December 04, 2018
Mirada Medical, a leading global brand in medical imaging software, will form part of an artificial intelligence (AI)...
Snoring Poses Greater Cardiac Risk to Women
News | Women's Health | November 29, 2018
Obstructive sleep apnea (OSA) and snoring may lead to earlier impairment of cardiac function in women than in men,...