Feature | November 26, 2013 | Simon Häger

Leverage ACR’s Dose Index Registry by Utilizing a Dose Monitoring Solution

The radical increase in patient exposure to radiation from medical imaging over the last two decades has created great concerns about its inherent risks. Today, one of the highest priorities on many hospital agendas is to break this trend by achieving improved control of the radiation exposure to their patients. 
 
The collection and monitoring of patient radiation dose is currently limited or non-existent in many imaging facilities which has provoked reaction by government agencies and state legislatures to establish laws and programs to collect and report on dose. There is no doubt that this has led the medical imaging community to take action to comply with these initiatives and gain a better control of the radiation exposure to their patients. 
 
ACR’s Dose Index Registry
ACR’s Dose Index Registry (DIR), a prominent data registry in the United States, allows facilities to compare their computed tomography (CT) dose indices to regional and national values. Information related to dose indices for all CT exams is collected, anonymized, transmitted, and stored in this data repository. Every six months, institutions receive feedback reports comparing their results (by body part and exam type) against aggregate values in an attempt to provide hospitals a way of benchmarking dose values.[1]  Unfortunately, the external comparison itself is not enough; appropriate action must be taken from within the facility to reduce and achieve better control of radiation exposure to make sure laws and the ALARA (as low as reasonably achievable) dose principals are followed. 
 
Utilizing a Dose Monitoring Solution
When an outlier in dose values for a specific procedure is identified in a feedback report, the next step is to determine the underlying reason for the deviation. The focus must move from external comparison to internal investigation. 
 
“Utilizing a dose monitoring solution is the most efficient way to collect and visualize the huge volume of data concerned with dose reporting,” said Ian Judd, product manager for Sectra DoseTrack. “Any solution should accept data from multiple sources such as EMR, RIS, modalities and PACS and provide analytical tools to allow for drill-down into details about the specific procedure and the underlying cause for exceptions.”
 
He said it is only by gathering data from multiple sources within the imaging arena that an effective dose reduction methodology can be implemented. When this is accomplished, appropriate dose reducing actions including adjusting protocols, configuring modalities and providing additional training to staff will be successful.
 
“A dose monitoring solution should allow for comparisons on multiple levels such as between X-ray equipment, staff, and departments to determine the reason why each exposure occurred,” Judd said. “Without the ability to look at the complete patient journey from initial referral to the finalized report, the customer will never truly be able to manage patient dose. The actual dose received is a single moment in time, however, there are many other key touch points in the care of the patient, which if not also analyzed, will never allow true dose reduction to be achieved. 
 
He said a dose tracking system provides confirmation and confidence in operating a quality, professional service. This confidence and proof can then be used to improve confidence in the level of service to referring clinicians and patients.
 
Both the Joint Commission (JCAHO) and U.S. Food and Drug Administration (FDA) have provided recommendations on capturing and transmitting dose information in the patient’s electronic medical record (EMR) as well as to a national dose registry.[2,3] Synergies can be achieved by utilizing a dose monitoring solution as a centralized portal to collect and send dose data to EMR’s and the DIR. 
 
Participating in the DIR provides an excellent path for imaging institutions to receive external feedback on how they perform against other facilities. However, without corrective action, that feedback is of limited value. By utilizing a dose monitoring solution, the institution can leverage the feedback from the DIR to internally investigate the underlying reasons for outliers. Only then, can appropriate actions be taken to reduce the overall radiation exposure to patients. 
 
Editor's note: The author Simon Häger is a Sectra DoseTrack team member. 
 
References
1. The American College of Radiology, "Dose Index Registry," 23 10 2013. [Online]. Available: http://www.acr.org/Quality-Safety/National-Radiology-Data-Registry/Dose-....
2. The Joint Commission on Accreditation of Health Organizations, "Sentinel Event Alert 47," The Joint Commission on Accreditation of Health Organizations, 2011.
3. U.S. Food and Drug Administration, "Initiative to Reduce Unnecessary Radiation Exposure from Medical Imaging," U.S. Food and Drug Administration, 9 2 2010. [Online]. Available: http://www.fda.gov/newsevents/newsroom/pressannouncements/ucm200085.htm?.... [Accessed 23 10 2013].
     
 
 
 
 
 

Related Content

Houston Methodist Hospital Enters Multi-Year Technology and Research Agreement With Siemens Healthineers
News | Imaging | August 17, 2017
Houston Methodist Hospital and Siemens Healthineers have entered into a multi-year agreement to bring cutting-edge...
Four Blue Cross Blue Shield Companies Issue Positive Medical Policies on HeartFlow FFRct Analysis
News | Computed Tomography (CT) | August 09, 2017
HeartFlow Inc. announced that four Blue Cross Blue Shield companies have each issued a positive medical policy for the...
Virtual Phantoms Inc. Releases VirtualDose-IR
Technology | Radiation Dose Management | August 07, 2017
Virtual Phantoms Inc. announced the release of VirtualDoseIR, a tool for assessing organ dose from interventional...
The American Lung Association created LUNG FORCE, a national movement to defeat lung cancer
News | Lung Cancer | August 02, 2017
To raise public awareness of lung cancer—the leading cancer killer of men and women—the American Lung Association's...
GE’s DoseWatch is a digital informatics solution that automatically collects, monitors and reports on radiation dose indices for diagnostic imaging exams
News | Radiation Dose Management | July 31, 2017
GE Healthcare announced that it has licensed computed tomography (CT) organ dosimetry technology developed at Duke...
Contrast Media from Bayer, trends in contrast media and developments in contrast media
Feature | Contrast Media | July 28, 2017 | By Dave Fornell
Here are several updates in medical imaging ...
Radiation dose tracking in medical imaging is helping increase patient safety by lower X-ray doses.
Feature | Radiation Dose Management | July 26, 2017 | Dave Fornell
Patient X-ray radiation exposure from medical imaging has been a hot topic in radiology the past few years and has pr
New York Hospital Finds Significant Cost Savings With Toshiba’s Aquilion One CT
News | Computed Tomography (CT) | July 25, 2017
In five years, Kaleida Health’s Stroke Care Center (SCC) at the Gates Vascular Institute in Buffalo, N.Y., has realized...
Samsung Introduces FDA-Cleared BodyTom Elite CT Scanner
Technology | Computed Tomography (CT) | July 24, 2017
Samsung announced U.S. Food and Drug Administration (FDA) approval of the BodyTom Elite, an upgraded version of its...
Sponsored Content | Videos | CT Angiography (CTA) | July 21, 2017
DAIC and ITN Editor Dave Fornell discusses some of the most innovative new computed tomography (CT) technology and tr
Overlay Init