62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine co

62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine concentration for diagnosis of pulmonary metastasis.


January 11, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), ringlike peripheral high iodine concentration maps from dual-energy CT (DECT) can help guide management in patients with known lung cancer and an indeterminate solitary nodule.

“Ringlike peripheral high iodine concentration had excellent interobserver agreement, showed high specificity (albeit poor sensitivity) for differentiating pulmonary metastasis from primary lung cancer, and independently predicted pulmonary metastasis,” wrote AJR first author Yoshinao Sato, MD, PhD, from the Diagnostic Imaging Center at Japan’s Cancer Institute Hospital in Tokyo.

This AJR accepted manuscript study included 93 patients (64 men, 29 women; median age, 70 years) who underwent resection of a primary lung cancer (n=68) or pulmonary metastasis (n=25) corresponding with a solid lesion on preoperative contrast-enhanced DECT performed between April 2020 and March 2021. After constructing venous-phase 120-keV single-energy images, equilibrium-phase 66-keV virtual monoenergetic images, as well as iodine concentration maps, two radiologists independently assessed lesions for the following: spiculated margins, air bronchograms, rim enhancement, and thin ringlike peripheral high iodine concentration.

Ultimately, ringlike peripheral high iodine concentration on DECT showed excellent interobserver agreement (κ=0.80), and had sensitivity of 52% and specificity of 81% for differentiating pulmonary metastases from primary lung cancers. Additionally, the finding independently predicted pulmonary metastasis in multivariate analysis [OR=7.81, 95% CI: 2.28–29.60; p=.001] combining patient and lesion characteristics.

“Iodine concentration maps from DECT could help determine the diagnosis for lesions that are equivocal for pulmonary metastasis on conventional images,” the authors of this AJR accepted manuscript reiterated.

For more information: www.arrs.org


Related Content

News | Artificial Intelligence

Dec. 1, 2025 — Researchers at the University of California, Berkeley and University of California, San Francisco have ...

Time December 10, 2025
arrow
News | Computed Tomography (CT)

A new study shows large increases in the use of computed tomography (CT) scans of the head in emergency departments ...

Time December 05, 2025
arrow
News | X-Ray

Dec. 1, 2025 – Zwanger-Pesiri Radiology, one of the most respected and technologically advanced outpatient radiology ...

Time December 03, 2025
arrow
News | FDA

Nov. 26, 2025 — a2z Radiology AI has received U.S. FDA clearance for a2z-Unified-Triage, a single device that flags and ...

Time December 03, 2025
arrow
News | Interventional Radiology

Dec. 1, 2025 — GE HealthCare has unveiled the Allia Moveo,1 an image guiding solution designed to enhance mobility and ...

Time December 02, 2025
arrow
News | Archive Cloud Storage

Nov. 30, 2025 — Gradient Health, Inc. has released Atlas 2, a major upgrade to its self-service medical imaging data ...

Time December 01, 2025
arrow
News | RSNA 2025

Nov. 13, 2025 — Nano-X Imaging Ltd., a medical imaging technology company, will showcase its Nanox.ARC X multi-source ...

Time November 25, 2025
arrow
News | Artificial Intelligence

Nov. 24, 2025 — Siemens Healthineers is launching artificial intelligence-enabled services to help healthcare providers ...

Time November 24, 2025
arrow
News | Artificial Intelligence

Nov. 20, 2025 — Aidoc has announced a collaboration with AdventHealth to launch one of the largest imaging AI ...

Time November 21, 2025
arrow
News | Radiology Business

Nov. 13, 2025 — Covera Health recently announced that Advanced Radiology Services (ARS) has joined its national Quality ...

Time November 17, 2025
arrow
Subscribe Now