62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine co

62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine concentration for diagnosis of pulmonary metastasis.


January 11, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), ringlike peripheral high iodine concentration maps from dual-energy CT (DECT) can help guide management in patients with known lung cancer and an indeterminate solitary nodule.

“Ringlike peripheral high iodine concentration had excellent interobserver agreement, showed high specificity (albeit poor sensitivity) for differentiating pulmonary metastasis from primary lung cancer, and independently predicted pulmonary metastasis,” wrote AJR first author Yoshinao Sato, MD, PhD, from the Diagnostic Imaging Center at Japan’s Cancer Institute Hospital in Tokyo.

This AJR accepted manuscript study included 93 patients (64 men, 29 women; median age, 70 years) who underwent resection of a primary lung cancer (n=68) or pulmonary metastasis (n=25) corresponding with a solid lesion on preoperative contrast-enhanced DECT performed between April 2020 and March 2021. After constructing venous-phase 120-keV single-energy images, equilibrium-phase 66-keV virtual monoenergetic images, as well as iodine concentration maps, two radiologists independently assessed lesions for the following: spiculated margins, air bronchograms, rim enhancement, and thin ringlike peripheral high iodine concentration.

Ultimately, ringlike peripheral high iodine concentration on DECT showed excellent interobserver agreement (κ=0.80), and had sensitivity of 52% and specificity of 81% for differentiating pulmonary metastases from primary lung cancers. Additionally, the finding independently predicted pulmonary metastasis in multivariate analysis [OR=7.81, 95% CI: 2.28–29.60; p=.001] combining patient and lesion characteristics.

“Iodine concentration maps from DECT could help determine the diagnosis for lesions that are equivocal for pulmonary metastasis on conventional images,” the authors of this AJR accepted manuscript reiterated.

For more information: www.arrs.org


Related Content

News | RSNA

Registration for RSNA 2026 is now open. The Radiological Society of North America's annual meeting will take place Nov ...

Time July 31, 2026
arrow
News | Innovative Hospitals

July 27, 2026 — Vanderbilt Health and Siemens Healthineers have entered into a multi-year, $87 million Value ...

Time July 28, 2026
arrow
News | Pediatric Imaging

July 17, 2026 — In June, UW Health Kids began welcoming patients into a new state-of-the-art imaging suite dedicated to ...

Time July 23, 2026
arrow
News | Information Technology

July 20, 2026 — GE HealthCare has introduced MIM Anyware, a remote access platform that provides secure, healthcare ...

Time July 20, 2026
arrow
News | ACR

July 15, 2026 — The American College of Radiology (ACR) recently issued a statement praising the inclusion of the ...

Time July 16, 2026
arrow
News | Cardiac Imaging

July 8, 2026 — Conavi Medical Corp. has announced the publication of a case report in the Journal of the Society for ...

Time July 15, 2026
arrow
News | PET Imaging

July 14, 2026 — New research is shedding new light on the biological basis of schizophrenia by directly measuring ...

Time July 15, 2026
arrow
News | Pediatric Imaging

June 16, 2026 — Crescom has officially launched a global clinical Proof of Concept (PoC) of its pediatric ...

Time June 24, 2026
arrow
Feature | X-Ray | Kyle Hardner

Water-window X-rays allow researchers to visualize biological cells at high contrast without staining agents or other ...

Time June 23, 2026
arrow
News | Artificial Intelligence

June 15, 2026 — HOPPR recently announced that HOPPR AI Foundry is now available in AWS Marketplace. The availability ...

Time June 19, 2026
arrow
Subscribe Now