News | Cardiovascular Ultrasound | March 15, 2019

Data from two studies evaluate accuracy, efficiency and reproducibility of cardiovascular ultrasound acquisition and calculation via artificial intelligence

Bay Labs Announces New Data on EchoGPS, AutoEF AI Software at ACC.19

March 15, 2019 — Artificial intelligence (AI) company Bay Labs announced the presentation of two studies assessing performance of the company’s deep learning software for cardiovascular imaging. The first evaluated the software when used by medical professionals with no prior ultrasound experience to acquire diagnostic-quality echocardiograms, and the second evaluated the fully automated calculation of ejection fraction (EF) with accuracy and increased reproducibility. Results from these studies will be presented at the American College of Cardiology (ACC) 68th Annual Scientific Session, March 16-18 in New Orleans.

Innovative Ultrasound Technologies EchoGPS and AutoEF Help Novices Perform Efficient and Accurate Echocardiographic Monitoring in Cancer Patients

An ongoing prospective study conducted at Stanford University is assessing the use of deep learning software to aid in cardiac function monitoring in cancer patients undergoing treatment with potentially cardiotoxic therapies. Bay Labs’ EchoGPS and AutoEF software are being used in the study to aid in the acquisition of limited views of a standard echocardiogram by providing users with no prior ultrasound experience real-time guidance to obtain cardiac views, and to automatically calculate a left ventricular EF. Cardiac function monitoring for cardiotoxicity caused by cancer treatments is recommended for at-risk patients, however such screening remains underutilized. While these tools are not yet U.S. Food and Drug Administration (FDA)-cleared or approved for these purposes, the preliminary data assess these products for this potential future use.

Alberta Yen, M.D., Division of Cardiovascular Medicine, Department of Medicine, Stanford University, will present preliminary study results demonstrating a strong potential use of EchoGPS and AutoEF in a busy cancer clinic for cardiac function monitoring. To date, 37 patients have undergone echocardiograms performed by novices, including oncologists and nurse practitioners in the oncology clinic, with EchoGPS and minimal supervision, with 100 patients planned in this prospective study. The AutoEF software deemed 76 percent of the studies of sufficient quality to generate an EF measurement, and the root mean square deviation in EF was 4.8 percent between AutoEF and echocardiographers. This suggests that the AutoEF measurements may be accurate when calculated from studies gathered using EchoGPS.  

“Results from our study suggest that future use of these technologies could enable clinicians to provide expanded access to cardiac monitoring in cancer patients,” said Yen. “Machine learning-based technology shows promise to expand access to screening echocardiography without overburdening echocardiography labs.”

Accuracy and Reproducibility of a Novel Artificial Intelligence Deep Learning-Based Algorithm For Automated Calculation of Ejection Fraction in Echocardiography

This study aimed to test the accuracy and reproducibility of an investigational update to Bay Labs’ AutoEF software for automated calculation of EF based on deep learning technology. Although EF is the single most clinically relevant parameter reported in echocardiography, high variability between readers limits its reliability.

Three expert cardiologists assessed EF of 99 patients that had imaging done as part of their routine evaluation, and their assessments were compared to the output of Bay Labs’ deep learning algorithm for automated calculation of EF (AutoEF). Cardiologists analyzed biplane tracings performed by three sonographers and AutoEF made its prediction from the clips selected by the sonographers. Accuracy between the investigational software and the average cardiologist prediction was 5.97 percent measured as mean absolute deviation (MAD). Reproducibility of EF calculations was best for AutoEF (2.94 percent MAD), compared to that of the cardiologists (4.74 percent MAD) and sonographers (6.96 percent MAD), which was calculated by comparing the mean absolute deviation of the three EF measurements from the sonographers, cardiologists and AutoEF. Federico Asch, M.D., FACC, FASE, director of the Echocardiography Core Lab at MedStar Health, concluded that automated calculation of EF using the investigational deep learning algorithm is accurate compared to expert cardiologists and that future use of these algorithms may improve accuracy and reproducibility. Asch will present the study at ACC.19.

For more information: www.baylabs.io


Related Content

News | Ultrasound Women's Health

Sept. 3, 2026 — Royal Philips has introduced the eV14-2v transvaginal transducer, expanding its obstetrics and ...

Time September 04, 2026
arrow
News | Ultrasound Imaging

Sept. 2, 2026 – Sonex Health and The Institute of Advanced Ultrasound Guided Procedures have announced publication of ...

Time September 04, 2026
arrow
News | Radiation Oncology

Sept. 2, 2026 — Children with one of the deadliest forms of brain cancer may benefit from an additional course of ...

Time September 03, 2026
arrow
News | Radiopharmaceuticals and Tracers

Aug. 30, 2026 — Bayer has announced the presentation of first detailed results from the Phase III REVEAL study, an ...

Time September 02, 2026
arrow
News | Radiology Imaging

Sept. 1, 2026— A new study from the Harvey L. Neiman Health Policy Institute found that the odds of imaging following an ...

Time September 01, 2026
arrow
News | Breast Imaging

Aug. 20, 2026 — Candelis, Inc. has announced a collaboration with GE HealthCare to support the distribution of Candelis ...

Time August 24, 2026
arrow
News | RSNA

Aug. 18, 2026 —The board of trustees of the Radiological Society of North America's (RSNA) Research & Education (R&E) ...

Time August 24, 2026
arrow
News | Clinical Trials

Aug.12, 2026 — Mendaera Inc. has announced results from a peer-reviewed study showing that its FDA-cleared Focalist ...

Time August 17, 2026
arrow
News | Radiology Business

Aug. 4, 2026 — Canon Medical Systems USA (CMSU) has appointed Tsuneo "Neo" Imai as president and chief executive officer ...

Time August 10, 2026
arrow
News | Radiology Imaging

Aug. 4, 2026 — A new study from the Harvey L. Neiman Health Policy Institute found that the time between an imaging scan ...

Time August 06, 2026
arrow
Subscribe Now