News | X-Ray | August 06, 2020

Ghost imaging approach could enable detailed movies of the heart with low-dose X-rays

Ghost imaging approach could enable detailed movies of the heart with low-dose X-rays

Researchers developed a high-resolution X-ray imaging technique based on ghost imaging that can capture the motion of rapidly moving objects. They used it to create a movie of a blade rotating at 100,000 frames per second. Image courtesy of Sharon Shwartz, Bar-Ilan University


August 6, 2020 — Researchers have demonstrated a new high-resolution X-ray imaging technique that can capture the motion of rapidly moving objects and quickly changing dynamics. The new method could be used for non-destructive imaging of moving mechanical components and to capture biological processes not previously available with medical X-ray imaging.

"The technique we demonstrated can be used with any x-ray source, plus it is low cost, simple and robust," said research team leader Sharon Shwartz from Bar-Ilan University in Israel. "Thus, it opens up the possibility of using X-rays to measure fast dynamics outside the lab."

In The Optical Society (OSA) journal Optics Express, the researchers describe their new X-ray imaging approach, which uses a non-traditional imaging method known as ghost imaging to achieve fast imaging speeds with high spatial resolution. They demonstrate the technique by creating an X-ray movie of a blade rotating at 100,000 frames per second.

"Medical imaging systems based on this technique could offer a new diagnostic tool for physicians," said Shwartz. "Our approach could, for example, be used to acquire high-resolution movies of the heart while greatly reducing the radiation dose for patients."

Seeing through surfaces

X-rays are useful for imaging because of their unique capability to penetrate surfaces that are opaque to visible wavelengths. Traditional X-ray imaging typically uses a pixelated camera with each pixel measuring the intensity level of the X-ray beam at a specific position.

Capturing higher resolution X-ray images requires more pixels, which, in turn, creates huge amounts of data that take time to transfer. This creates a trade-off between imaging speed and spatial resolution that makes it impossible to capture high-speed events with high resolution. Although very specialized techniques involving extremely powerful X-rays can overcome this trade-off, these X-ray sources are only available at large synchrotrons found at a few facilities around the world.

In the new work, the researchers turned to ghost imaging because it uses single-pixel detectors that can improve the imaging speed. Ghost imaging works by correlating two beams — in this case, X-ray beams — that do not individually carry any meaningful information about the object. One beam encodes a random pattern that acts as a reference and never directly probes the sample. The other beam passes through the sample. Because very little x-ray power comes into contact with the object being imaged, ghost imaging can also help reduce X-ray exposure when used for medical imaging.

"Although single-pixel detectors can be much faster than pixelated detectors, they do not provide the spatial resolution necessary for image reconstruction," said Shwartz. "We used ghost imaging to overcome this problem and showed that we can image fast dynamics with spatial resolution comparable to or even better than the state-of-the-art X-ray pixelated detectors."

A simple solution

To create the reference beam needed for ghost imaging, the researchers used standard sandpaper mounted on motorized stages to create a random pattern that was recorded with a high-resolution, slow framerate pixelated X-ray camera. As the stage was moved to each position, the X-ray beam hit a different area of the sandpaper, creating random X-ray transmissions, or intensity fluctuations.

They then removed the pixelated camera from the X-ray beam and inserted the object to be imaged and a single-pixel detector. They moved the motorized stages to irradiate the object with the intensity fluctuation patterns introduced at the various positions of the sandpaper and then measured the total intensity after the beam hit the object by using the single-pixel detector.

To use this approach to image a fast-moving blade, the researchers synchronized the measurements with the blade's movement. A final image could then be reconstructed by correlating the reference pattern with the intensity measured by the single-pixel detector for each position of the blade.

The researchers created a movie of the moving blade by performing image reconstruction frame-by-frame to capture the blade at different positions. The resulting movie clearly shows the motion with a spatial resolution of about 40 microns — nearly an order of magnitude better than the resolution of currently available medical imaging systems.

The researchers are continuing to make improvements to the overall system as well as the image reconstruction algorithm to improve resolution and shorten measurement times.

For more information: www.osa.org


Related Content

News | Innovative Hospitals

July 27, 2026 — Vanderbilt Health and Siemens Healthineers have entered into a multi-year, $87 million Value ...

Time July 28, 2026
arrow
News | Computed Tomography (CT)

July 23, 2026 — HOPPR has introduced HOPPR EF Chest CT Narrative Model, a foundation model that processes 3D chest CT ...

Time July 27, 2026
arrow
News | Pediatric Imaging

July 17, 2026 — In June, UW Health Kids began welcoming patients into a new state-of-the-art imaging suite dedicated to ...

Time July 23, 2026
arrow
News | Point-of-Care Ultrasound (POCUS)

July 21, 2026 — Fujifilm Sonosite has launched Sonosite iLOOK, a compact ultrasound solution designed specifically for ...

Time July 22, 2026
arrow
News | Information Technology

July 20, 2026 — GE HealthCare has introduced MIM Anyware, a remote access platform that provides secure, healthcare ...

Time July 20, 2026
arrow
News | ACR

July 15, 2026 — The American College of Radiology (ACR) recently issued a statement praising the inclusion of the ...

Time July 16, 2026
arrow
News | Cardiac Imaging

July 8, 2026 — Conavi Medical Corp. has announced the publication of a case report in the Journal of the Society for ...

Time July 15, 2026
arrow
News | PET Imaging

July 14, 2026 — New research is shedding new light on the biological basis of schizophrenia by directly measuring ...

Time July 15, 2026
arrow
News | Pediatric Imaging

June 16, 2026 — Crescom has officially launched a global clinical Proof of Concept (PoC) of its pediatric ...

Time June 24, 2026
arrow
Feature | X-Ray | Kyle Hardner

Water-window X-rays allow researchers to visualize biological cells at high contrast without staining agents or other ...

Time June 23, 2026
arrow
Subscribe Now