FDA Investigates Site Using Eight Times Normal Level of Radiation in CT

October 12, 2009 - The FDA notified healthcare professionals that it has become aware of radiation overexposures during perfusion CT imaging performed to aid in the diagnosis of stroke at a particular facility, the patients receiving radiation doses that were approximately eight times the expected level.

While this event involved a single kind of diagnostic test at one facility, the magnitude of these overdoses and their impact on the affected patients were significant. This situation may reflect more widespread problems with CT quality assurance programs and may not be isolated to this particular facility or this imaging procedure (CT brain perfusion). If patient doses are higher than the expected level, but not high enough to produce obvious signs of radiation injury, the problem may go undetected and unreported, putting patients at increased risk for long-term radiation effects.

FDA encourages every facility performing CT imaging to review its CT protocols and be aware of the dose indices normally displayed on the control panel. These indices include the volume computed tomography dose index and the dose-length product. For each protocol selected, and before scanning the patient, carefully monitor the dose indices displayed on the control panel. To prevent accidental overexposure, make sure that the values displayed reasonably correspond to the doses normally associated with the protocol. Confirm this again after the patient has been scanned. Patients should follow their doctor’s recommendations for receiving CT scans. While unnecessary radiation exposure should be avoided, a medically-needed CT scan has benefits that outweigh the radiation risks.

For more information:
http://www.fda.gov/Safety/MedWatch/SafetyInformation/SafetyAlertsforHuma...

Related Content

Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
The Fujifilm FCT Embrace CT System displayed for the first time at ASTRO 2018.
360 Photos | 360 View Photos | November 07, 2018
Fujifilm's first FDA-cleared compu...
MaxQ AI Receives FDA Clearance for Accipio Ix Intracranial Hemorrhage Platform
Technology | Artificial Intelligence | November 07, 2018
MaxQ AI announced that its Accipio Ix intracranial hemorrhage (ICH) detection software has received 510(k) clearance...
GE Healthcare Discovery RF Gen 2 system displayed at ASTRO 2018. It is a dedicated computed tomography (CT) scanner for radiation oncology
360 Photos | 360 View Photos | November 07, 2018
This is the GE Healthcare Discovery RF Gen 2 system displayed at the ...
Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Sponsored Content | Case Study | Computed Tomography (CT) | November 06, 2018
The following is a summary of a study published in the
The NeuViz 16 Essence from Neusoft Medical Systems.

The NeuViz 16 Essence from Neusoft Medical Systems.

Feature | Computed Tomography (CT) | November 05, 2018 | By Melinda Taschetta-Millane
According to an industry mark...
Carestream Spotlights Healthcare IT and Imaging Systems at RSNA 2018
News | Information Technology | October 31, 2018
Carestream announced it will be displaying several imaging and healthcare information technology (IT) offerings at the...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...
Fujifilm Unveils FCT Embrace CT System for Oncology
Technology | Computed Tomography (CT) | October 23, 2018
Fujifilm Medical Systems U.S.A. Inc. recently introduced the FCT Embrace computed tomography (CT) system. Powered by...
The Aquilion Precision CT system from Canon offers very high resolution imaging, which may aid in cancer detection and improved treatment planning in radiation oncology. #ASTRO2018 #ASTRO #ASTRO18

The Aquilion Precision CT system from Canon offers very high resolution imaging, which may aid in cancer detection and improved treatment planning in radiation oncology. 

News | Computed Tomography (CT) | October 19, 2018
October 19, 2018 – At the 2018 American Society of...