News | FDA | April 20, 2026

The Spectral CT Verida system combines spectral imaging with AI reconstruction to deliver enhanced levels of image quality, efficiency and clinical insight across radiology, cardiology and oncology.

computed tomography, Philips,

Philips Spectral CT Verida System (Photo: Royal Philips)


April 16, 2026 — Royal Philips has received U.S. Food and Drug Administration 510(k) clearance for the Philips Spectral CT Verida system, bringing its next-generation, AI-powered spectral CT innovation to the United States.

Verida incorporates Spectral Precise Image, with a third-generation Nano-panel Precise dual-layer detector with intrinsic noise reduction, along with an AI-based deep learning reconstruction engine, designed to reduce noise and enhance image quality across CT applications1. Clinicians are able to customize optimal image de-noising according to their preferences.

“With FDA clearance for Verida, we are bringing the next evolution of spectral CT to more markets,” said Dan Xu, Business Leader of CT at Philips. “By combining always-on spectral imaging with AI-powered reconstruction, Verida enables clinicians to see more, first time right, supporting faster, more informed decisions and expanding the role of CT across clinical pathways.”

Built on Philips’ industry-leading detector-based spectral CT technology, Verida enables always-on spectral imaging without requiring separate scans or workflow changes. It includes system and software enhancements designed to support clinical workflow, including improvements to the spectral result generation pipeline and updated computing infrastructure to support performance and usability. Verida reconstructs 145 images per second, so entire exams automatically appear in less than 30 seconds – 2× faster than previously, enabling up to 270 exams every day2.

By capturing both high- and low-energy data in a single acquisition, clinicians can access conventional and spectral results simultaneously, supporting enhanced tissue characterization and material differentiation. This approach eliminates the need for pre-selection or repeat scans, enabling first-time-right imaging and deeper clinical insight across a broad range of applications3.

Verida is a computed tomography X-ray system intended for diagnostic imaging in radiology, interventional radiology, and cardiology, and in oncology as part of treatment preparation and radiation therapy planning. It is indicated for head, whole body, cardiac, and vascular CT applications in patients of all ages1. The system is also intended to be used for low dose CT lung cancer screening when performed within established screening protocols4. Extended field-of-view images and respiratory correlated scanning (4DCT) are for treatment preparation and radiation therapy planning/simulation use only3.

For more information about the Philips Spectral CT Verida system, visit the Philips website. 

 

* Data on file

  1. Spectral Precise Image is an AI-based reconstruction feature with supplemental data for clinical interpretation and does not replace professional clinical judgement. SPI has been clinically evaluated in adults (≥22 years); pediatric use has not been clinically validated.
  2. Spectral CT Verida Premium up to 270 (4 CIRS config) exams a day (16 hours dual shift working day) meeting the needs of radiology departments with extended work hours and very high patient throughput.
  3. See Instructions for Use for complete indications, limitations, and feature-specific restrictions.
  4. Please refer to clinical literature, including the results of the National Lung Screening Trial (NEngl. J Med 2011; 365:395-409) and subsequent literature, for further information.

 


Related Content

News | Breast Imaging

July 7, 2026 — QT Imaging Holdings, Inc. recently announced it has successfully completed its first routine inspection ...

Time July 07, 2026
arrow
News | Mammography

June 30, 2026 — The Food and Drug Administration has cleared new contrast-enhanced mammography (CEM) and CEM biopsy ...

Time June 30, 2026
arrow
News | Radiology Imaging

June 15, 2026 — Lead Glass Pro, a supplier of radiation shielding products, has expanded its turnkey installation ...

Time June 18, 2026
arrow
News | Computed Tomography (CT)

June 10, 2026 — Subtle Medical has received FDA clearance for SubtleHD (CT), an AI-powered image enhancement solution ...

Time June 17, 2026
arrow
News | Contrast Agents

June 15, 2026 – Bayer has announced that the U.S. Food and Drug Administration (FDA) approved Ambelvist (gadoquatrane) ...

Time June 16, 2026
arrow
News | FDA

June 4, 2026 — GE HealthCare has received 510(k) clearance from the United States Food and Drug Administration (FDA) for ...

Time June 05, 2026
arrow
News | Radiopharmaceuticals and Tracers

June 1, 2026 — Serac Healthcare Ltd. has presented Phase 2 data showing that SPECT-CT imaging with the radiotracer 99mTc ...

Time June 01, 2026
arrow
News | PET Imaging

May 29, 2026 — GE HealthCare recently announced that its MIM KineticID modeling software1 is now 510(k) pending with the ...

Time May 29, 2026
arrow
News | Radiopharmaceuticals and Tracers

May 27, 2026 — Subtle Medical has received FDA clearance for its SubtleHD (PET), the company's next-generation AI ...

Time May 27, 2026
arrow
News | X-Ray

May 21, 2026 — RADIN Health and AZmed have announced the expansion of their strategic partnership and enhance radiology ...

Time May 22, 2026
arrow
Subscribe Now