Feature | July 30, 2012 | Dave Fornell

New CT Scanner Technology Highlighted at SCCT 2012

Detector hardware, software advances help improve image quality at a lower dose

The Aquilion Prime system has an 80-slice detector, but can be upgraded in the field to a 180-slice system.

Siemens' Stellar detector was released in early 2012. The detector uses mirocircuits in place of soldered circuit boards, which helps reduce electronic noise, providing for clearer images at lower radiation doses.

Siemens' Stellar detector was released in early 2012. The detector uses mirocircuits in place of soldered circuit boards, which helps reduce electronic noise, providing for clearer images at lower radiation doses.

Computed tomography (CT) vendors highlighted several recent improvements to their imaging systems during the 2012 Society of Cardiovascular CT (SCCT) annual scientific meeting in July in Baltimore, Md.  

GE highlighted its Discovery CT750 HD FREEdom scanner, which offers a new type of detector for better signal-to-noise ratios and new reconstruction software to reduce stitching artifacts and noise of low-dose scans. It also offers the ability to perform dual energy scans using a single X-ray tube modulated every 0.5 milliseconds between 80 and 140 kVp.

The system’s FREEdom (Fast Registered Energies and ECG) software offers intelligent motion correction via SnapShot Freeze, enhanced coronary visualization even in the presence of calcium, detailed plaque material composition assessment and accurate perfusion calculations. SnapShot Freeze is supposed to significantly reduce coronary motion and overcome the limitation of all hardware-only solutions. It precisely detects vessel motion and velocity and determines actual vessel position and makes corrections.

“SnapShot Freeze will be a game changer by improving the effective temporal resolution, and from the initial images, I see significantly reduced motion artifacts and significantly improved image clarity,” said James Min, director of cardiac imaging research and co-director of cardiac imaging at Cedars Sinai Hospital and current president of SCCT. He is a principal investigator for the VICTORY trial, which is evaluating the diagnostic accuracy of SnapShot Freeze motion and stitching artifact correction.

Toshiba’s newest CT system is the Aquilion Prime, which is the replacement for its previous 64-slice system. It is an 80-slice system that can be upgraded in the field over a weekend to a 180-slice system. It offers a 78 mm bore and has 660-pound capacity tables to accommodate larger patients.

Earlier this year, Siemens introduced the new Stellar detector for its CT systems, which uses integrated, printed microcircuits instead of soldered circuit boards. This reduces the amount of electronic noise in scans by about 20 percent. The new detectors also overall improve image quality by reducing calcium and metal blooming, so it is easier to evaluate in-stent restenosis.

Related Content

Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
News | Advanced Visualization | November 13, 2018
Canon Medical Systems USA and Applied Radiology will host a pair of expert-led forums in high-resolution imaging and...
The Fujifilm FCT Embrace CT System displayed for the first time at ASTRO 2018.
360 Photos | 360 View Photos | November 07, 2018
Fujifilm's first FDA-cleared compu...
MaxQ AI Receives FDA Clearance for Accipio Ix Intracranial Hemorrhage Platform
Technology | Artificial Intelligence | November 07, 2018
MaxQ AI announced that its Accipio Ix intracranial hemorrhage (ICH) detection software has received 510(k) clearance...
GE Healthcare Discovery RF Gen 2 system displayed at ASTRO 2018. It is a dedicated computed tomography (CT) scanner for radiation oncology
360 Photos | 360 View Photos | November 07, 2018
This is the GE Healthcare Discovery RF Gen 2 system displayed at the ...
Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Results of the vertebrae-based analysis (383 vertebrae in 34 patients) for detection of BME.

Sponsored Content | Case Study | Computed Tomography (CT) | November 06, 2018
The following is a summary of a study published in the
The NeuViz 16 Essence from Neusoft Medical Systems.

The NeuViz 16 Essence from Neusoft Medical Systems.

Feature | Computed Tomography (CT) | November 05, 2018 | By Melinda Taschetta-Millane
According to an industry mark...
Deaconess Health System Chooses Sectra as Enterprise Imaging Vendor
News | Enterprise Imaging | November 02, 2018
International medical imaging information technology (IT) and cybersecurity company Sectra will install its enterprise...
Carestream Spotlights Healthcare IT and Imaging Systems at RSNA 2018
News | Information Technology | October 31, 2018
Carestream announced it will be displaying several imaging and healthcare information technology (IT) offerings at the...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...