Feature | July 30, 2012 | Dave Fornell

New CT Scanner Technology Highlighted at SCCT 2012

Detector hardware, software advances help improve image quality at a lower dose

The Aquilion Prime system has an 80-slice detector, but can be upgraded in the field to a 180-slice system.

Siemens' Stellar detector was released in early 2012. The detector uses mirocircuits in place of soldered circuit boards, which helps reduce electronic noise, providing for clearer images at lower radiation doses.

Siemens' Stellar detector was released in early 2012. The detector uses mirocircuits in place of soldered circuit boards, which helps reduce electronic noise, providing for clearer images at lower radiation doses.

Computed tomography (CT) vendors highlighted several recent improvements to their imaging systems during the 2012 Society of Cardiovascular CT (SCCT) annual scientific meeting in July in Baltimore, Md.  

GE highlighted its Discovery CT750 HD FREEdom scanner, which offers a new type of detector for better signal-to-noise ratios and new reconstruction software to reduce stitching artifacts and noise of low-dose scans. It also offers the ability to perform dual energy scans using a single X-ray tube modulated every 0.5 milliseconds between 80 and 140 kVp.

The system’s FREEdom (Fast Registered Energies and ECG) software offers intelligent motion correction via SnapShot Freeze, enhanced coronary visualization even in the presence of calcium, detailed plaque material composition assessment and accurate perfusion calculations. SnapShot Freeze is supposed to significantly reduce coronary motion and overcome the limitation of all hardware-only solutions. It precisely detects vessel motion and velocity and determines actual vessel position and makes corrections.

“SnapShot Freeze will be a game changer by improving the effective temporal resolution, and from the initial images, I see significantly reduced motion artifacts and significantly improved image clarity,” said James Min, director of cardiac imaging research and co-director of cardiac imaging at Cedars Sinai Hospital and current president of SCCT. He is a principal investigator for the VICTORY trial, which is evaluating the diagnostic accuracy of SnapShot Freeze motion and stitching artifact correction.

Toshiba’s newest CT system is the Aquilion Prime, which is the replacement for its previous 64-slice system. It is an 80-slice system that can be upgraded in the field over a weekend to a 180-slice system. It offers a 78 mm bore and has 660-pound capacity tables to accommodate larger patients.

Earlier this year, Siemens introduced the new Stellar detector for its CT systems, which uses integrated, printed microcircuits instead of soldered circuit boards. This reduces the amount of electronic noise in scans by about 20 percent. The new detectors also overall improve image quality by reducing calcium and metal blooming, so it is easier to evaluate in-stent restenosis.

Related Content

Hospital for Special Surgery Invests in Sectra Orthopedic 3-D Planning Software
News | Orthopedic Imaging | January 18, 2018
January 18, 2018 – International medical imaging IT and cybersecurity company Sectra announces that Hospital for Spec
Philips Introduces Technology Maximizer Program for Imaging Equipment Upgrades
Technology | Imaging | January 17, 2018
January 17, 2018 — Philips recently announced the launch of Technology Maximizer, a cross-modality program designed t
Sponsored Content | Videos | Enterprise Imaging | January 16, 2018
Built on an over 25-year pioneering legacy in the advanced visualization industry, Vital continues to expand on three
RSNA 2017 Celebrates Innovation in Radiology
News | Imaging | January 15, 2018
January 15, 2018 — The Radiological Society of North America’s...
Fat Distribution in Women and Men Provides Clues to Heart Attack Risk
News | Women's Health | January 11, 2018
January 11, 2018 – It’s not the amount of fat in your body but where it is stored that may increase your risk for hea
Emergency Radiologists See Inner Toll of Opioid Use Disorders

Rates of Imaging Positivity for IV-SUDs Complications. Image courtesy of Efren J. Flores, M.D.

News | Clinical Study | January 11, 2018
January 11, 2018 – Emergency radiologists are seeing a high prevalence of patients with complications related to opio
Minimally Invasive Treatment Provides Relief from Back Pain

Lumbar spine MRI showing disc herniation and nerve root at baseline and one month after treatment

News | Interventional Radiology | January 11, 2018
The majority of patients were pain free after receiving a new image-guided pulsed radiofrequency treatment for low back...
CT Shows Enlarged Aortas in Former Pro Football Players

3-D rendering from a cardiac CT dataset demonstrating mild dilation of the ascending aorta.

News | Computed Tomography (CT) | January 11, 2018
Former National Football League (NFL) players are more likely to have enlarged aortas, a condition that may put them at...

Size comparison between 3-D printed prosthesis implant and a penny.

News | 3-D Printing | January 11, 2018
January 11, 2018 — Researchers using...
EchoPixel Showcases Next-Generation Surgical Planning With True 3-D Interactive Mixed Reality Software
News | Advanced Visualization | January 08, 2018
January 8, 2018 — EchoPixel showcased the latest version of True 3D, its interactive,...
Overlay Init