new study published on European Radiology evaluates the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based denoising technique with ClariCT.AI for pediatric abdominal CT, compared with that of standard iodine concentration single-energy polychromatic CT (SECT).

January 19, 2021 — Radiation exposure and side effects related to iodine contrast agents are the two main concerns of contrast enhanced computed tomography (CT) examinations. A new study published in European Radiology evaluates the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based denoising technique with ClariCT.AI for pediatric abdominal CT, compared with that of standard iodine concentration single-energy polychromatic CT (SECT). ClariCT.AI is an AI-based CT image denoising solution from ClariPi, Inc. The study reported that the use of a deep learning–based denoising technique was able to produce the same overall image and diagnostic quality of lesions despite a reduced iodine dose and decreased radiation dose. According to the study, the advantage of the low-concentration iodine use in conjunction with DECT and deep learning-based denoising was two-fold. The results show that the CT dose index and total iodine administration in DECT were respectively 19.6% and 14.3% lower than those in SECT.

The study method was done with DECT with 300 mg•I/mL contrast medium and was performed in 29 pediatric patients (17 boys, 12 girls; age, 2–19 years). The DECT images were reconstructed using a noise-optimized virtual mono-energetic reconstruction image (VMI) with a deep learning method. SECT images with 350 mg•I/mL contrast medium, performed within the last 3 months before the DECT, served as reference images. The quantitative and qualitative parameters were compared using paired t tests and Wilcoxon signed-rank tests, and the differences in radiation dose and total iodine administration were assessed.

The article concluded that ClariCT.AI deep learning-based noise-optimized VMI data using low iodine concentration (300 mg•I/mL) could maintain image quality while reducing radiation dose and iodine load. Therefore, this approach may be beneficial for pediatric abdominal CT scans.

For more information: www.claripi.com


Related Content

News | Digital Pathology

March 11, 2026 — Royal Philips has announced the expansion of its digital pathology portfolio with new cloud-enabled ...

Time March 26, 2026
arrow
News | Magnetic Resonance Imaging (MRI)

March 25, 2026 A Penn Medicine–led team has developed a first‑of‑its‑kind artificial intelligence system that interprets ...

Time March 26, 2026
arrow
News | FDA

March 24, 2026 — MARS Bioimaging, a New Zealand–headquartered medical device company, has received U.S. Food and Drug ...

Time March 25, 2026
arrow
News | Cybersecurity

March 23, 2026 —Sacumen has launched ConnectX, a unified AI platform that gives cybersecurity product companies full ...

Time March 25, 2026
arrow
News | Radiology Imaging

March 23, 2026 — Samsung Medison hsa announced that its U.S. medical imaging businesses, previously operating as ...

Time March 23, 2026
arrow
News | Radiology Business

March 1, 2026 — A new study from the Harvey L. Neiman Health Policy Institute found that practice turnover (i.e ...

Time March 19, 2026
arrow
News | Magnetic Resonance Imaging (MRI)

March 18, 2026 — GE HealthCare and Springbok Analytics have entered a development agreement that will aim to leverage ...

Time March 18, 2026
arrow
News | Radiology Education

March 17, 2026 – The Center for Radiology Education (CRE) has announced a nationwide initiative to provide scholarships* ...

Time March 17, 2026
arrow
News | Breast Imaging

March 10, 2026 — QT Imaging Holdings has received U.S. Food and Drug Administration (FDA) 510(k) clearance for an ...

Time March 13, 2026
arrow
News | Radiology Business

March 12, 2026 — DelveInsight's has released its latest Diagnostic Imaging Equipment Market Insights report. The in ...

Time March 13, 2026
arrow
Subscribe Now