new study published on European Radiology evaluates the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based denoising technique with ClariCT.AI for pediatric abdominal CT, compared with that of standard iodine concentration single-energy polychromatic CT (SECT).

January 19, 2021 — Radiation exposure and side effects related to iodine contrast agents are the two main concerns of contrast enhanced computed tomography (CT) examinations. A new study published in European Radiology evaluates the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning–based denoising technique with ClariCT.AI for pediatric abdominal CT, compared with that of standard iodine concentration single-energy polychromatic CT (SECT). ClariCT.AI is an AI-based CT image denoising solution from ClariPi, Inc. The study reported that the use of a deep learning–based denoising technique was able to produce the same overall image and diagnostic quality of lesions despite a reduced iodine dose and decreased radiation dose. According to the study, the advantage of the low-concentration iodine use in conjunction with DECT and deep learning-based denoising was two-fold. The results show that the CT dose index and total iodine administration in DECT were respectively 19.6% and 14.3% lower than those in SECT.

The study method was done with DECT with 300 mg•I/mL contrast medium and was performed in 29 pediatric patients (17 boys, 12 girls; age, 2–19 years). The DECT images were reconstructed using a noise-optimized virtual mono-energetic reconstruction image (VMI) with a deep learning method. SECT images with 350 mg•I/mL contrast medium, performed within the last 3 months before the DECT, served as reference images. The quantitative and qualitative parameters were compared using paired t tests and Wilcoxon signed-rank tests, and the differences in radiation dose and total iodine administration were assessed.

The article concluded that ClariCT.AI deep learning-based noise-optimized VMI data using low iodine concentration (300 mg•I/mL) could maintain image quality while reducing radiation dose and iodine load. Therefore, this approach may be beneficial for pediatric abdominal CT scans.

For more information: www.claripi.com


Related Content

News | Ultrasound Imaging

April 9, 2026 — GE HealthCare has announced a digital integration between the GE HealthCare bkActiv intraoperative ...

Time April 09, 2026
arrow
News | Radiology Imaging

April 7, 2026 — Onvida Health and Siemens Healthineers have entered a 10-year Value Partnership¹ designed to bring the ...

Time April 09, 2026
arrow
News | Teleradiology

April 1, 2026 — Premier Radiology Services has acquired Global Imaging Solutions (GLOBIS), a leading teleradiology group ...

Time April 03, 2026
arrow
News | Ultrasound Imaging

March 30, 2026 — Butterfly Network, Inc. has received clearance from the U.S. Food and Drug Administration (FDA) for a ...

Time April 01, 2026
arrow
News | Computed Tomography (CT)

March 30, 2026 — HCA Healthcare’s Good Samaritan Hospital is the first hospital in the Bay Area to implement Lumina 3D ...

Time April 01, 2026
arrow
News | Digital Pathology

March 29, 2026 — Leica Microsystems has introduced the Viventis SCAPE light sheet microscope. Viventis SCAPE enables ...

Time April 01, 2026
arrow
News | Radiology Business

March 31, 2026 — Radon Medical Imaging, a medical imaging equipment maintenance and repair services company, has has ...

Time March 31, 2026
arrow
News | Radiology Imaging

March 26, 2026 — GE HealthCare has announced a renewed research collaboration with Stanford Medicine Department of ...

Time March 30, 2026
arrow
News | Cardiac Imaging

March 28, 2026 — When Ashley Perlow felt a sharp pain shoot across her chest and into both wrists, she didn't think it ...

Time March 30, 2026
arrow
News | Digital Pathology

March 11, 2026 — Royal Philips has announced the expansion of its digital pathology portfolio with new cloud-enabled ...

Time March 26, 2026
arrow
Subscribe Now