CT systems, MRI Systems, Digital Radiography systems, RSNA 2014

December 10, 2014 — Morgan Advanced Materials high voltage (HV) and radio frequency (RF) capacitors used in X-ray generators, along with a range of metallised ceramics and assemblies used in X-ray tubes, CT scanners and MRI systems were displayed at RSNA 2014.

Manufactured from Morgan’s 36 and K77 dielectric materials, the high power HV and RF capacitors are non-magnetic making them suitable for use in medical imaging equipment. Additionally, the capacitors demonstrate low electrical loss and have a high dielectric strength to enable them to carry high electrical loads over a wide frequency range. They can also be custom-designed for the precise tuning of MRI scanners.

Offering high mechanical strength, vacuum integrity and good thermal conductivity, Morgan’s range of metallised components include RF windows, medical linear accelerator metallised rings and high power insulators for cyclotrons. Additionally, its high voltage feedthroughs have been engineered to maintain very high levels of vacuum and joint integrity via a robust hermetic seal, ideal for extreme operating conditions from elevated temperatures to cryogenic conditions.

Also showcased was a range of air-in-line sensors for the detection of air bubbles in medical dosing equipment. The sensors enable increased control over the detection of air bubbles in liquids, which, if undetected, could hamper the functioning of drug delivery systems, or allow bubbles to enter the patient’s bloodstream – a potentially fatal consequence. Enhanced AIL sensors allow the detection of the size of air bubbles in tubes, meaning sensors can be easily configured for different applications.

Morgan's Composites and Defence Systems business produces bespoke composite structures for healthcare applications; including a high strength, lightweight carbon fibre X-ray therapy couch top for oncology treatment procedures. Through precise fibre orientation in lay-up and detailed product validation, Morgan is able to produce components with low and consistent material density to optimize X-ray transparency to ensure high quality images and optimal consistency of the component throughout its service life.

For more information: www.morganadvancedmaterials.com/healthcare


Related Content

News | Computed Tomography (CT)

Sept. 26, 2025 — At the American Society for Radiation Oncology (ASTRO) 2025 annual meeting in San Francisco, Calif ...

Time September 29, 2025
arrow
News | Mammography

Sept. 3, 2025 — According to ARRS’ American Journal of Roentgenology (AJR), a commercial artificial intelligence (AI) ...

Time September 09, 2025
arrow
News | Computed Tomography (CT)

Aug. 26, 2025— Esaote North America, Inc., a provider of dedicated MRI, Ultrasound, and Healthcare IT solutions, has ...

Time August 27, 2025
arrow
News | Lung Imaging

Aug. 26, 2025 — Optellum, a global leader in AI for lung health, recently announced the world’s first thorax CT ...

Time August 26, 2025
arrow
News | RSNA

Aug. 13, 2025 — Registration is now open for the RSNA 111th Scientific Assembly and Annual Meeting, the world’s leading ...

Time August 13, 2025
arrow
News | Radiology Imaging

Aug. 12, 2025 – Medical imaging methods such as ultrasound and MRI are often affected by background noise, which can ...

Time August 12, 2025
arrow
News | Artificial Intelligence

July 22, 2025 — GE HealthCare has topped a U.S. Food and Drug Administration (FDA) list of AI-enabled medical device ...

Time July 23, 2025
arrow
News | Prostate Cancer

July 16, 2025 — Artificial intelligence can improve diagnostic consistency and reduce false-positives in prostate cancer ...

Time July 22, 2025
arrow
News | Breast Imaging

QT Imaging Holdings, Inc. has announced the launch of its latest QTviewer, version 2.8. QTviewer stores and displays the ...

Time July 21, 2025
arrow
News | Prostate Cancer

June 26, 2025 – Quibim, a global provider of quantitative medical imaging solutions, has launched AI-QUAL, a new feature ...

Time June 26, 2025
arrow
Subscribe Now