January 25, 2010 – Physicians’ reduce radiation dose by 20 percent exposure to emergency department patients with suspected PE without compromising patient safety in response to an educational intervention, reported a study published in the February issue of American Roentgen Ray Society.

Researchers in the Department of Radiology, Albert Einstein College of Medicine, Bronx, NY, set out to determine whether the radiation exposure to patients with suspected pulmonary embolism (PE) could be decreased by safely increasing the use of ventilation–perfusion (V/Q) scanning and decreasing the use of CT pulmonary angiography (CTPA) through an educational intervention.

The collaborative educational seminars were held among the radiology, nuclear medicine, and emergency medicine departments in December 2006 and January 2007, regarding the radiation dose and accuracies of V/Q scanning and CTPA for diagnosing PE. An imaging algorithm was introduced for reducing radiation exposure, which physicians applied to emergency department patients with a clinical suspicion of PE underwent chest radiography. If the chest radiograph was normal, V/Q scanning was recommended, otherwise CTPA was recommended.

The researchers retrospectively tracked the number and results of CTPA and V/Q scanning and calculated mean radiation effective dose before and after the intervention.

The number of CTPA examinations performed decreased from 1,234 in 2006 to 920 in 2007, and the number of V/Q scans increased from 745 in 2006 to 1,216 in 2007. The mean effective dose was reduced by 20 percent, from 8.0 mSv in 2006 to 6.4 mSv in 2007 (p

Patients in the study in 2006 were of similar age, while in 2007, those who underwent V/Q scanning were significantly younger. There was no significant difference in the false-negative rate (range, 0.8–1.2%) between CTPA and V/Q scanning in 2006 and 2007.

Physicians’ practice patterns changed in response to an educational intervention, resulting in a reduction in radiation exposure to emergency department patients with suspected PE without compromising patient safety

Reference: Stein, E., Haramati, B., et al. Success of a Safe and Simple Algorithm to Reduce Use of CT Pulmonary Angiography in the Emergency Department. AJR 2010; 194:392-397.

For more information: www.ajronline.org


Related Content

News | X-Ray

April 29, 2026 — Results from a new study* presented at the American Roentgen Ray Society’s (ARRS) 2026 annual meeting ...

Time April 29, 2026
arrow
News | Imaging Software Development

April 28, 2026 — Avatar Medical has been granted FDA 510(k) clearance for Avatar Medical Vision, its software platform ...

Time April 28, 2026
arrow
News | Cardiac Imaging

April 28, 2026 — Abbott has received U.S. Food and Drug Administration (FDA) clearance and CE Mark for its next ...

Time April 28, 2026
arrow
News | FDA

April 16, 2026 — Royal Philips has received U.S. Food and Drug Administration 510(k) clearance for the Philips Spectral ...

Time April 20, 2026
arrow
News | Radiology Imaging

April 7, 2026 — Onvida Health and Siemens Healthineers have entered a 10-year Value Partnership¹ designed to bring the ...

Time April 09, 2026
arrow
News | Radiology Business

March 31, 2026 — Radon Medical Imaging, a medical imaging equipment maintenance and repair services company, has has ...

Time March 31, 2026
arrow
News | Radiology Imaging

March 26, 2026 — GE HealthCare has announced a renewed research collaboration with Stanford Medicine Department of ...

Time March 30, 2026
arrow
News | Cardiac Imaging

March 28, 2026 — When Ashley Perlow felt a sharp pain shoot across her chest and into both wrists, she didn't think it ...

Time March 30, 2026
arrow
News | FDA

March 24, 2026 — MARS Bioimaging, a New Zealand–headquartered medical device company, has received U.S. Food and Drug ...

Time March 25, 2026
arrow
News | Radiology Imaging

March 23, 2026 — Samsung Medison hsa announced that its U.S. medical imaging businesses, previously operating as ...

Time March 23, 2026
arrow
Subscribe Now