Study Shows Patient-Specific Guides Aid in Osteotomies Around the Knee

February 15, 2011 – A successful pilot study found the feasibility of using computer-assisted surgical planning and patient-specific surgical guides in correcting lower limb malalignment. In the study, Materialise's SurgiCase Orthopaedics was used to describe lower limb malalignment and virtually plan multi-planar correction using computed tomography (CT) scans.

The trial showed that planned corrections can be obtained and fixed accurately during surgery with the help of Materialise's patient-specific surgical guides. It was conducted by J. Victor, M.D., AZ St. Lucas, Brugge, Belgium.

Despite recent innovations, lower limb malalignment continues to be corrected using traditional methods and techniques, such as relying on 2-D plain X-rays and using rulers and protractors. However, this can be prone to error and, in some cases, inaccurate in multi-planar deformities. The aim of the pilot study was to evaluate the feasibility of virtual pre-operative 3-D planning and correct execution of osteotomies around the knee with the aid of patient-specific surgical guides.

Eight patients presenting with significant malalignment of the lower limb were included in the study (7 valgus, 1 varus knee). Pre-operative CT scans of the affected limbs and the normal contra-lateral side were obtained and sent to Materialise where 3-D models of the patients' anatomy were created. These models made it possible for Victor to carefully evaluate the three-planar deformity of each patient and identify customized surgical corrections.

After creating the virtual surgical plans, the Materialise team - in close collaboration with Victor - continued designing the patient-specific surgical guides used to perform the planar osteotomy and achieve the planned wedge opening and hinge axis orientation. These guides were also used in the drilling of the planned screw holes and thus, determined the position of the plate relative to the bone. Post-operative assessments of the corrections were obtained through AP and lateral X-rays, and full leg standing X-rays.

The results of the study are promising. All of the patient-specific guides were successfully used during surgery and accurately guided the osteotomy plane and screw holes. The guides fit uniquely onto the patients' bones and it was possible to perform the osteotomies through the guides. The predrilled screw holes matched the locking plates and adequate fixations were obtained. No significant peri-operative complications occurred.

For more information: www.materialise.com

Related Content

DR 800 multi-purpose digital imaging system with Dynamic Musica
News | Digital Radiography (DR) | July 20, 2018
Agfa displayed the new DR 800 multi-purpose digital imaging system with Dynamic ...
Fujifilm to Host Pediatric Imaging Best Practices Symposium at AHRA 2018
News | Pediatric Imaging | July 18, 2018
Fujifilm Medical Systems U.S.A. Inc. announced that it will offer educational opportunities and exhibit its latest...
Study Points to Need for Performance Standards for EHR Usability and Safety
News | Electronic Medical Records (EMR) | July 18, 2018
A novel new study provides compelling evidence that the design, development and implementation of electronic health...
Artificial Intelligence Provides Faster, Clearer MRI Scans

A new artificial-intelligence-based approach to image reconstruction, called AUTOMAP, yields higher quality images from less data, reducing radiation doses for CT and PET and shortening scan times for MRI. Shown here are MR images reconstructed from the same data with conventional approaches, at left, and AUTOMAP, at right. Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital

News | Artificial Intelligence | July 17, 2018
A research team with funding from the National Institute for Biomedical Imaging and Bioengineering (NIBIB) has...
iSchemaView Brings RAPID Imaging Platform to Australia and New Zealand
News | Stroke | July 13, 2018
iSchemaView has signed Diagnostic Imaging Australia (DIA) to be the exclusive distributor for the RAPID cerebrovascular...
Guerbet, IBM Watson Health Partner on Artificial Intelligence for Liver Imaging
News | Clinical Decision Support | July 10, 2018
Guerbet announced it has signed an exclusive joint development agreement with IBM Watson Health to develop an...
3-D Imaging and Computer Modeling Capture Breast Duct Development

An image of a developing mammary duct. Image courtesy of Andrew Ewald.

News | Breast Imaging | June 28, 2018
A team of biologists has joined up with civil engineers to create what is believed to be the first 3-D computer model...
FDA Clears Bay Labs' EchoMD AutoEF Software for AI Echo Analysis
Technology | Cardiovascular Ultrasound | June 19, 2018
Cardiovascular imaging artificial intelligence (AI) company Bay Labs announced its EchoMD AutoEF software received 510(...
3D Systems Announces On Demand Anatomical Modeling Service
Technology | Medical 3-D Printing | June 18, 2018
3D Systems announced availability of its new On Demand Anatomical Modeling Service. This new service provides a wide...
Weight-Bearing CT International Study Group Hosts  Scientific Session at AOFAS Conference
News | Computed Tomography (CT) | June 15, 2018
June 15, 2018 —The Weight-Bearing CT International Study Group will host a scientific session on the benefits of weig
Overlay Init