News | Flat Panel Displays | August 11, 2015

Study Shows Eizo RadiForce RX850 Improves Reader Efficiency Over Dual Configuration

Radiologists spent average of nearly seven fewer seconds reading 8-megapixel single screen compared to combined 10-megapixel dual screens

eizo Radiforce RX850
eizo Radiforce RX850

August 11, 2015 — A new research study from the University of Arizona Department of Medical Imaging demonstrated that the Eizo RadiForce RX850 8-megapixel monitor significantly improves reader efficiency over a multi-monitor configuration.

The study, headed by Elizabeth A. Krupinski, Ph.D., compared the RadiForce RX850 with two 5-megapixel RadiForce GX540 monitors when viewing mammography images. Radiologists were asked to view a set of mammographic cases, once in each format, and determine for each case if a lesion was present or absent.

Overall, the difference in resolution between the RX850 compared with the combined resolution of the two 5 megapixel monitors (10 megapixels) did not appear to influence the readers’ ability to detect a lesion, demonstrating consistent diagnostic accuracy with the streamlined single screen.

The obtrusive bezels in multi-monitor configurations may cause a disruption of the eyes’ ability to smoothly scan information between two separate monitors. The study showed that the number of times radiologists scanned from one image to the other was significantly less with the RX850 compared to the two 5 megapixel monitors.

On average, the radiologists spent 62.04 seconds viewing the single screen and 68.99 seconds viewing the dual screens. This showed that the single RadiForce RX850 reduced overall time spent viewing images by an average of nearly 7 seconds (about 10 percent) compared to the dual RadiForce GX540 monitors. This could contribute to a more efficient mammography workflow by saving time per case.

Krupinski said, “Having the images side by side literally makes it easier for the visual and the cognitive system of the radiologist to take in more information. Plus [there is] the gain in efficiency. If it takes less time to view the images but render the same diagnostic decision, that certainly is an advantage.”

For more information: www.eizo.com

Related Content

Doctor-Patient Discussions Neglect Potential Harms of Lung Cancer Screening
News | Lung Cancer | August 15, 2018
August 15, 2018 — Although national guidelines advise doctors to discuss the benefits and harms of...
Illinois Governor Approves State Breast Density Reporting Bill Into Law
News | Breast Density | August 13, 2018
Illinois Gov. Bruce Rauner approved the Illinois Breast Density Reporting Law (Public Act 100-0749) on Aug. 10, 2018...
PET Tracer Identifies Estrogen Receptor Expression Differences in Breast Cancer Patients
News | PET Imaging | August 09, 2018
In metastatic breast cancer, prognosis and treatment is largely influenced by estrogen receptor (ER) expression of the...
iCAD Receives FDA Clearance of PowerLook Density Assessment for Digital Breast Tomosynthesis
Technology | Breast Density | August 08, 2018
iCAD announced U.S. Food and Drug Administration (FDA) clearance of its latest artificial intelligence (AI) software...
Cardiac Imaging Reveals Roots of Preeclampsia Damage in Pregnant Women
News | Women's Health | August 07, 2018
Johns Hopkins researchers say a heart imaging study of scores of pregnant women with the most severe and dangerous form...
Cardiac Monitoring a Higher Priority for High-Risk Breast Cancer Patients
News | Cardio-oncology | August 07, 2018
August 7, 2018 — While heart failure is an uncommon complication of...
Hologic Acquires Digital Specimen Radiography Company Faxitron Bioptics

VisionCT 3-D breast specimen-designated computed tomography (CT) system. Image courtesy of Faxitron Bioptics.

News | Breast Imaging | July 31, 2018
Hologic Inc. announced it has completed the acquisition of Faxitron Bioptics, a privately-held leader in digital...
Konica Minolta Hosting Lunch and Learn at 23rd Annual Mammography Meeting in Santa Fe
News | Breast Imaging | July 31, 2018
Konica Minolta Healthcare Americas Inc. will sponsor a lunch and learn featuring its Exa Mammo platform during the 23rd...
FDA Approves New Tomosynthesis Quality Control Tests for ACR Digital Mammography QC Manual
News | Mammography | July 30, 2018
The U.S. Food and Drug Administration (FDA) recently approved the American College of Radiology’s (ACR’s) amendment to...
The Magtrace and Sentimag Magnetic Localization System uses magnetic detection during sentinel lymph node biopsy procedures to identify specific lymph nodes, known as sentinel lymph nodes, for surgical removal. The FDA granted approval of the Sentimag System to Endomagnetics Inc.

The  Endomagnetics' Magtrace and Sentimag Magnetic Localization System uses magnetic detection during sentinel lymph node biopsy procedures to identify specific lymph nodes, known as sentinel lymph nodes, for surgical removal.

Technology | Women's Health | July 24, 2018
July 24, 2018 — The U.S.
Overlay Init