News | November 20, 2012

Stereoscopic Mammography Could Reduce Recall Rate

A new three-dimensional (3-D) digital mammography technique has the potential to significantly improve the accuracy of breast cancer screening, according to a study published in Radiology.

Two-dimensional (2-D) x-ray mammography, the current primary screening method for early detection of breast cancer in women, is a valuable tool but has some limitations. Surrounding normal tissue can mask lesions, and 2-D views do not provide direct information about the volumetric appearance—meaning the three-dimensional physical shape—of a detected lesion.

A novel technique called stereoscopic digital mammography (SDM) addresses these limitations by mimicking the way that human eyes work together to form a 3-D image. The technique uses digital mammography equipment that’s been modified to allow the X-ray tube to move separately from the cassette. The resulting images are viewed on two monitors mounted one above the other.

“Our eyes see the world from two slightly different perspectives,” said Carl J. D’Orsi, M.D., from the Department of Radiology and Imaging Sciences at Emory University School of Medicine and the Winship Cancer Institute at Emory University, both in Atlanta. “In this technique, the X-ray tube functions as the eyeball, with two different images providing slightly different views of the internal structure of the breast.”

By using a unique workstation and polarizing lenses, SDM has the ability to identify lesions at different depths within the breast volume, potentially reducing both false positive findings and recalls while enabling more accurate diagnosis.

D’Orsi and colleagues recently compared SDM to 2-D digital mammography in 779 patients at elevated risk of developing breast cancer because of personal or family history. Patients received both exams in a single visit, and two experienced radiologists independently interpreted the final total of 1,298 exams. Imaging findings were correlated with results of one-year follow up or biopsy.

SDM significantly improved the accuracy of cancer detection. The specificity of 91.2 percent was better than the 87.8 percent rate for 2-D digital mammography; and the accuracy of 90.9 percent, compared with 87.4 percent for 2-D digital mammography, was also a statistically significant improvement.

“We found that the stereoscopic technique could significantly decrease the need for calling women back for additional exams,” D’Orsi said.

D’Orsi and colleagues are expanding their research to study SDM with a lower radiation dose in the general screening population. The radiation dose used in the study was approximately double the standard dose for mammography.

“In this study, we used a high-risk population to get an adequate number of cancers, and we acquired each of the images comprising the stereo pairs with a full standard X-ray dose,” he said. “Now that we know the technique is worthwhile, we’re repeating the study in the general population with a dose comparable to routine screening mammography.”

“Stereoscopic Digital Mammography: Improved Specificity and Reduced Rate of Recall in a Prospective Clinical Trial.” Collaborating with Dr. D’Orsi were David J. Getty, Ph.D., Ronald M. Pickett, Ph.D., Ioannis Sechopoulos, Ph.D., Mary S. Newell, M.D., Kathleen R. Gundry, M.D., Sandra R. Bates, M.D., Robert M. Nishikawa, Ph.D., Edward A. Sickles, M.D., Andrew Karellas, Ph.D., and Ellen M. D’Orsi, R.T. (R)(M).

Radiology is edited by Herbert Y. Kressel, M.D., Harvard Medical School, Boston, Mass., and owned and published by the Radiological Society of North America, Inc. (http://radiology.rsna.org/)

RSNA is an association of more than 50,000 radiologists, radiation oncologists, medical physicists and related scientists, promoting excellence in patient care and health care delivery through education, research and technologic innovation. The Society is based in Oak Brook, Ill. For more information: www.radiologyinfo.org

 

Related Content

Illinois Governor Approves State Breast Density Reporting Bill Into Law
News | Breast Density | August 13, 2018
Illinois Gov. Bruce Rauner approved the Illinois Breast Density Reporting Law (Public Act 100-0749) on Aug. 10, 2018...
PET Tracer Identifies Estrogen Receptor Expression Differences in Breast Cancer Patients
News | PET Imaging | August 09, 2018
In metastatic breast cancer, prognosis and treatment is largely influenced by estrogen receptor (ER) expression of the...
iCAD Receives FDA Clearance of PowerLook Density Assessment for Digital Breast Tomosynthesis
Technology | Breast Density | August 08, 2018
iCAD announced U.S. Food and Drug Administration (FDA) clearance of its latest artificial intelligence (AI) software...
Cardiac Imaging Reveals Roots of Preeclampsia Damage in Pregnant Women
News | Women's Health | August 07, 2018
Johns Hopkins researchers say a heart imaging study of scores of pregnant women with the most severe and dangerous form...
Cardiac Monitoring a Higher Priority for High-Risk Breast Cancer Patients
News | Cardio-oncology | August 07, 2018
August 7, 2018 — While heart failure is an uncommon complication of...
Hologic Acquires Digital Specimen Radiography Company Faxitron Bioptics

VisionCT 3-D breast specimen-designated computed tomography (CT) system. Image courtesy of Faxitron Bioptics.

News | Breast Imaging | July 31, 2018
Hologic Inc. announced it has completed the acquisition of Faxitron Bioptics, a privately-held leader in digital...
Konica Minolta Hosting Lunch and Learn at 23rd Annual Mammography Meeting in Santa Fe
News | Breast Imaging | July 31, 2018
Konica Minolta Healthcare Americas Inc. will sponsor a lunch and learn featuring its Exa Mammo platform during the 23rd...
FDA Approves New Tomosynthesis Quality Control Tests for ACR Digital Mammography QC Manual
News | Mammography | July 30, 2018
The U.S. Food and Drug Administration (FDA) recently approved the American College of Radiology’s (ACR’s) amendment to...
The Magtrace and Sentimag Magnetic Localization System uses magnetic detection during sentinel lymph node biopsy procedures to identify specific lymph nodes, known as sentinel lymph nodes, for surgical removal. The FDA granted approval of the Sentimag System to Endomagnetics Inc.

The  Endomagnetics' Magtrace and Sentimag Magnetic Localization System uses magnetic detection during sentinel lymph node biopsy procedures to identify specific lymph nodes, known as sentinel lymph nodes, for surgical removal.

Technology | Women's Health | July 24, 2018
July 24, 2018 — The U.S.
Overlay Init