News | November 25, 2007

Siemens Rolls Out Two New MRI Systems, Feature Tim Technology

November 26, 2007 - Siemens Medical Solutions introduced two new MRI systems at RSNA 2007, the MAGNETOM Essenza, featuring 30 mT/m gradients, reportedly delivering excellent image quality for all clinical applications, and the MAGNETOM Verio, which combines image quality at 3T field strength and a 70-centimeter open bore that aims to offer exceptional patient comfort in one solution.

Both of these systems offer Siemens unique Tim (Total imaging matrix) technology, which eliminates the need for patient repositioning and manual coil changes during scans, while enhancing image quality. Tim technology can help MRI departments achieve advanced clinical and workflow capabilities, according to the company.

The 1.5T MAGNETOM Essenza weighs in at 3.5 tons, allowing a facility more installation options as the magnet can be installed on higher floors. The system has a length 145 centimeters, which is the second shortest system length offered by Siemens. If the system is replacing an existing MRI, it can reportedly reduce energy consumption by up to 50 percent. The magnet also has zero helium boil-off so there is no need to regularly refill the expensive cooling substance, and the system is always ready for operation. The system also includes the IsoCenter Matrix coil, which is installed at the center of the magnet, aiming to ensure it is always in the correct position, providing a workflow solution that leads to improved image quality, according to the company.

Due to the Verio’s 70-centimeter bore diameter, the average distance between a patient’s eyes and the magnet is 30 centimeters, reportedly alleviating concerns of claustrophobia in many patients. In addition, the wider space makes it possible to scan patients who could not be examined with the MRI system in the past, including those suffering from kyphosis (limited mobility) or those who are in pain, as well as pediatric and obese patients up to 550 pounds, those who are dependent on medical devices, those who are in intensive care, and those having to undergo intraoperative procedures.

With a system length of only 173 centimeters, the MAGNETOM Verio is currently the shortest 3T MRI system on the market, while having the footprint of a 1.5T MRI system, according to Siemens. Furthermore, it is equipped with a magnet of six tons, compared to other 3T systems. The installation costs for the MAGNETOM Verio are minimized and the system also uses a zero helium boil-off technology.

For more information: www.usa.siemens.com/medical

Related Content

Technology | Focused Ultrasound Therapy | June 19, 2018
EDAP TMS SA has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for its Focal One device for...
Elekta Unity High-Field MR-Linac Receives CE Mark
News | Image Guided Radiation Therapy (IGRT) | June 18, 2018
Elekta announced that its Elekta Unity magnetic resonance radiation therapy (MR/RT) system has received CE mark,...
Washington University in St. Louis Begins Clinical Treatments With ViewRay MRIdian Linac
News | Image Guided Radiation Therapy (IGRT) | June 14, 2018
June 14, 2018 — The Siteman Cancer Center at Barnes-Jewish Hospital and Washington University School of Medicine in S
Reduced hippocampal volume on MRI

This figure shows reduced hippocampal volume over the course of 6 years as seen on progressive volumetric analysis and also coronal MRI evaluations (arrows).Progressive volume loss in the mesial temporal lobe on MRI is a characteristic imaging feature of AD. This patient was a case of Alzheimer’s Dementia.

 

News | Neuro Imaging | June 12, 2018
According to a UCLA Medical Center study, a new technology shows the potential to help doctors better determine when...
High Prevalence of Atherosclerosis Found in Lower Risk Patients
News | Magnetic Resonance Imaging (MRI) | June 08, 2018
Whole-body magnetic resonance angiography (MRA) found a surprisingly high prevalence of atherosclerosis in people...
Philips Receives FDA 510(k) for Ingenia Elition MR System
Technology | Magnetic Resonance Imaging (MRI) | June 07, 2018
Philips announced that it has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for its...
New Studies Highlight MRI Use for Prostate Cancer Screening and Management
News | Magnetic Resonance Imaging (MRI) | May 21, 2018
Three new studies presented at the 113th annual meeting of the American Urological Association (AUA) highlight the...
MRI "Glove" Provides New Look at Hand Anatomy

An experiment showed that a glove-shaped detector could yield images of bones, cartilage, and muscles interacting as a hand 'plays piano.' Traditionally, MRI had required patients to remain strictly motionless.Image courtesy of Nature Biomedical Engineering; Bei Zhang, Martijn Cloos, Daniel Sodickson

News | Magnetic Resonance Imaging (MRI) | May 17, 2018
A new kind of magnetic resonance imaging (MRI) component in the shape of a glove delivers the first clear images of...
FDA Clears Medic Vision's iQMR MRI Image Enhancement Technology

Image courtesy of Medic Vision Imaging Solutions

Technology | Magnetic Resonance Imaging (MRI) | May 15, 2018
May 15, 2018 — Medic Vision Imaging Solutions Ltd. announced that the U.S.
Impaired Brain Pathways May Cause Attention Problems After Stroke
News | Neuro Imaging | May 10, 2018
Damage to some of the pathways that carry information throughout the brain may be responsible for attention deficit in...
Overlay Init