News | January 02, 2013

New processing software simplifies workflow for minimally invasive heart valve implantation

Segmentation of the aortic root including anatomical landmarks.


January 2, 2013 — Siemens Healthcare recently received clearance from the U.S. Food and Drug Administration (FDA) for syngo Aortic ValveGuide, an integrated image processing software that helps cardiologists and cardiac surgeons prepare and perform transcatheter aortic valve replacement (TAVR). The syngo Aortic ValveGuide automatically reconstructs a 3-D representation of the aortic root from cross-sectional images acquired with the angiography system and provides the best projection angle for the valve replacement. The software selects anatomical landmarks and overlays the 3-D image with 2-D images acquired during live fluoroscopy, enabling the physician to obtain real-time 3-D guidance in the patient’s body while navigating the new valve to its intended location. This groundbreaking software, which is now available to customers, reflects the spirit of Siemens Healthcare’s Agenda 2013 — a recently announced two-year initiative designed in part to strengthen the Healthcare Sector's innovative power and competitiveness.

During the minimally invasive TAVR intervention, an artificial aortic valve is inserted via the femoral artery or through the apex of the heart. syngo Aortic ValveGuide provides the physician with automated 3-D guidance by segmenting the aortic root in 3-D mode from images created using the angiography system. With the aid of anatomical landmarks in the 3-D vessel representation, syngo Aortic ValveGuide calculates the exact perpendicular view on the aortic root. The C-arm adjusts to the corresponding angulations for live fluoroscopy, enabling the physician to precisely position the new valve. Consequently, as soon as the software overlays the 3-D image of the aorta with the 2-D live fluoroscopy, the cath lab cardiologist – or, respectively, the heart surgeon in the hybrid OR — can begin the intervention. Since syngo Aortic ValveGuide only requires a short fluoroscopy time prior to the procedure, the patient's exposure to radiation and contrast can be reduced considerably.

Prior to syngo Aortic ValveGuide, users had to rely on preprocedural (or intraprocedural) computed tomography (CT), manually co-registering it with live fluoroscopy and overlaying it on a live fluoroscopy image to determine the correct angulation. This process required additional steps and highly skilled personnel. The new syngo Aortic ValveGuide uses syngo DynaCT Cardiac — Siemens software that processes CT-like cardiac images from images acquired using the angiography system.

"syngo DynaCT allows us to evaluate the anatomy of the aortic root and the position of the coronary ostiae. The overlay of the intra-procedural 3-D image over live fluoroscopy gives us an additional level of confidence for the valve implantation," says William O'Neill, M.D., professor of medicine and cardiology, executive dean for clinical affairs and interim-executive dean for research and research training at the Miller School of Medicine and chief medical officer at University of Miami Health System. "The automated workflow of the syngo Aortic ValveGuide makes the procedure easier — and the indication of a perpendicular view plane helps to make it even safer."

For more information: www.siemens.com/healthcare


Related Content

News | RSNA

Registration for RSNA 2026 is now open. The Radiological Society of North America's annual meeting will take place Nov ...

Time July 31, 2026
arrow
News | Innovative Hospitals

July 27, 2026 — Vanderbilt Health and Siemens Healthineers have entered into a multi-year, $87 million Value ...

Time July 28, 2026
arrow
News | Pediatric Imaging

July 17, 2026 — In June, UW Health Kids began welcoming patients into a new state-of-the-art imaging suite dedicated to ...

Time July 23, 2026
arrow
News | Information Technology

July 20, 2026 — GE HealthCare has introduced MIM Anyware, a remote access platform that provides secure, healthcare ...

Time July 20, 2026
arrow
News | ACR

July 15, 2026 — The American College of Radiology (ACR) recently issued a statement praising the inclusion of the ...

Time July 16, 2026
arrow
News | Cardiac Imaging

July 8, 2026 — Conavi Medical Corp. has announced the publication of a case report in the Journal of the Society for ...

Time July 15, 2026
arrow
News | PET Imaging

July 14, 2026 — New research is shedding new light on the biological basis of schizophrenia by directly measuring ...

Time July 15, 2026
arrow
News | PACS

July 8, 2026 — Freeland Systems, a cloud PACS and clinical imaging software company, has launched its new customer ...

Time July 10, 2026
arrow
News | Pediatric Imaging

June 16, 2026 — Crescom has officially launched a global clinical Proof of Concept (PoC) of its pediatric ...

Time June 24, 2026
arrow
Feature | X-Ray | Kyle Hardner

Water-window X-rays allow researchers to visualize biological cells at high contrast without staining agents or other ...

Time June 23, 2026
arrow
Subscribe Now