News | Angiography | March 10, 2017

Miniature Particle Accelerator Saves on Contrast Agents for Angiography

X-rays from the MuCLS compact synchrotron at Technical University of Munich open up new possibilities for heart examinations

Technical University of Munich, Munich Compact Light Source, MuCLS, angiography, contrast agents

(a) Photograph of the sample in waterbath. (b) Empty image of full MuCLS beam. (c) Quasi-mono-energetic angiography image of a porcine heart acquired at the MuCLS, with iodine-based contrast agent injected into the left coronary artery. Visible are the left anterior descending artery (LAD) and the left circumflex artery (LCX). Image courtesy of the authors.

March 10, 2017 — The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical University of Munich (TUM) has now demonstrated that the required quantity of these substances can be significantly reduced if monoenergetic X-rays from a miniature particle accelerator are used.

Soft tissues such as organs and blood vessels are nearly impossible to examine in X-ray images. To detect a narrowing or other changes in coronary blood vessels, patients are therefore usually injected with an iodinated contrast agent.

These substances can sometimes be hazardous to health, however: "Particularly in patients with kidney insufficiency, complications may arise, in some cases even kidney failure," explained Daniela Münzel, M.D., an adjunct teaching professor for radiology at TUM's Klinikum rechts der Isar. "That is why we are studying possibilities of using lower concentrations of contrast agents."

One approach to reducing the dosage has now been developed by scientists from the Department of Diagnostic and Interventional Radiology at the Klinikum rechts der Isar, working in close cooperation with the Chair of Biomedical Physics at TUM's Department of Physics. The method, which they have described in a paper published in Nature Scientific Reports, is not based on new contrast agents. Instead it relies on special X-rays generated using the Munich Compact Light Source (MuCLS), the world's first mini-synchrotron, which was officially inaugurated at TUM at the end of 2015.

"Conventional X-ray sources generate a relatively broad range of energy levels. By contrast, the energy of X-rays produced by the MuCLS can be controlled much more precisely," said physicist Elena Eggl, the first author of the paper.

Contrast agents such as iodine and gadolinium have an absorption edge. That means that when the substance is exposed to X-rays of a certain energy, the contrast of the final image of the marked organ is particularly good. Below the absorption edge — about 30 kiloelectron volts (keV) for iodine — the contrast deteriorates rapidly. The contrast also becomes weaker at energies far above the absorption edge.

As a result, when using conventional broad-spectrum X-ray sources, an adequate quantity of contrast agent must always be used in order to offset this effect and obtain a sufficiently sharp image for a diagnosis. The MuCLS can generate X-rays that have exactly the optimal energy level. The capability of producing such monoenergetic X-rays has existed for some time. In the past, however, this was possible only with circular particle accelerators with a diameter of several hundred meters. In contrast, the MuCLS is comparable in size to a car.

The data shows that monoenergetic X-rays would make it possible to decrease the required concentration of iodine by about one third with no loss of contrast. For gadolinium, there would even be a somewhat greater reduction. A lot more research is needed, however, before real patients can be examined with monoenergetic X-rays.

"We're still at the very beginning of the development of this technology," said Eggl. The MuCLS is the very first machine of its kind. Moreover, it is designed for fundamental research, and not for examining patients. But with detailed computer simulations and tests with a pig's heart, using blood vessels dyed with iodine, the researchers were able to demonstrate feasibility of the method.

Franz Pfeiffer, professor of biomedical physics at TUM, sees the team's results as a promising start for medical research with the compact synchrotron: "The MuCLS offers numerous possibilities for medical applications that we plan to continue researching with our partners in medical fields,” he said.

The research was funded by the German Research Foundation (DFG), Munich-Centre for Advanced Photonics (MAP) cluster of excellence, the Center for Advanced Laser Applications (CALA), the Ministry for Education and Research, and the DFG Gottfried Wilhelm Leibniz Program.

For more information: www.nature.com/srep

References
Eggl E.,  Mechlem K., Braig E., Kulpe S., et al. "Mono-Energy Coronary Angiography with a Compact Synchrotron Source". Scientific Reports. Published online Feb. 9, 2017. DOI:10.1038/srep42211

Related Content

Appropriate Use Criteria Published for Valvular Heart Disease Imaging Tests
News | Clinical Decision Support | October 16, 2017
The American College of Cardiology (ACC), along with several partnering societies, recently released appropriate use...
ASNC and ASE Team Up to Expand ImageGuide Registry
News | Cardiovascular Ultrasound | October 12, 2017
The American Society of Nuclear Cardiology (ASNC) and the American Society of Echocardiography (ASE) jointly announced...
ACR Appropriateness Criteria Add Topics, Increase Diagnostic Imaging Clinical Scenarios
News | Clinical Decision Support | October 11, 2017
October 11, 2017 — Radiologists can enhance the quality and effectiveness of care with the newest release of the...
Guerbet to Participate in French Interventional Radiology Conference
News | Contrast Media | October 10, 2017
Guerbet announced it will be taking part in the 65th edition of the Journées Francophones de Radiologie (JFR) that will...
Medis Releases QAngio CT v3.1
Technology | Computed Tomography (CT) | October 09, 2017
October 9, 2017 — Medis has released a new version of its QAngio...
Trends in contrast media used in magnetic resonance imaging and computed tomography

Image courtesy of Bayer

Feature | Contrast Media | October 04, 2017 | By Dave Fornell
Over the past decade, several clinical studies have shown gadolinium-based magnetic resonance imaging (MRI) contrast...
Toshiba Highlights Interventional Imaging at RSNA 2017
News | Interventional Radiology | September 27, 2017
Toshiba Medical announced it will highlight several of its latest vascular and interventional imaging solutions at the...
Toshiba Showcases MRI Workflow Enhancements at RSNA 2017
News | Magnetic Resonance Imaging (MRI) | September 21, 2017
September 21, 2017 — Toshiba Medical will highlight its latest...
Philips Launches CardioMD IV Cardiac SPECT Solution at ASNC 2017
Technology | SPECT Imaging | September 15, 2017
September 15, 2017 — Philips highlighted its newest solution for...
Mississippi Surgical and Vascular Center Uses Toshiba Ultimax-I FPD to Save Patients' Limbs
News | Angiography | September 14, 2017
The southern U.S. sees some of the highest numbers of chronic medical conditions, such as peripheral artery disease...
Overlay Init