News | Angiography | March 10, 2017

Miniature Particle Accelerator Saves on Contrast Agents for Angiography

X-rays from the MuCLS compact synchrotron at Technical University of Munich open up new possibilities for heart examinations

Technical University of Munich, Munich Compact Light Source, MuCLS, angiography, contrast agents

(a) Photograph of the sample in waterbath. (b) Empty image of full MuCLS beam. (c) Quasi-mono-energetic angiography image of a porcine heart acquired at the MuCLS, with iodine-based contrast agent injected into the left coronary artery. Visible are the left anterior descending artery (LAD) and the left circumflex artery (LCX). Image courtesy of the authors.

March 10, 2017 — The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical University of Munich (TUM) has now demonstrated that the required quantity of these substances can be significantly reduced if monoenergetic X-rays from a miniature particle accelerator are used.

Soft tissues such as organs and blood vessels are nearly impossible to examine in X-ray images. To detect a narrowing or other changes in coronary blood vessels, patients are therefore usually injected with an iodinated contrast agent.

These substances can sometimes be hazardous to health, however: "Particularly in patients with kidney insufficiency, complications may arise, in some cases even kidney failure," explained Daniela Münzel, M.D., an adjunct teaching professor for radiology at TUM's Klinikum rechts der Isar. "That is why we are studying possibilities of using lower concentrations of contrast agents."

One approach to reducing the dosage has now been developed by scientists from the Department of Diagnostic and Interventional Radiology at the Klinikum rechts der Isar, working in close cooperation with the Chair of Biomedical Physics at TUM's Department of Physics. The method, which they have described in a paper published in Nature Scientific Reports, is not based on new contrast agents. Instead it relies on special X-rays generated using the Munich Compact Light Source (MuCLS), the world's first mini-synchrotron, which was officially inaugurated at TUM at the end of 2015.

"Conventional X-ray sources generate a relatively broad range of energy levels. By contrast, the energy of X-rays produced by the MuCLS can be controlled much more precisely," said physicist Elena Eggl, the first author of the paper.

Contrast agents such as iodine and gadolinium have an absorption edge. That means that when the substance is exposed to X-rays of a certain energy, the contrast of the final image of the marked organ is particularly good. Below the absorption edge — about 30 kiloelectron volts (keV) for iodine — the contrast deteriorates rapidly. The contrast also becomes weaker at energies far above the absorption edge.

As a result, when using conventional broad-spectrum X-ray sources, an adequate quantity of contrast agent must always be used in order to offset this effect and obtain a sufficiently sharp image for a diagnosis. The MuCLS can generate X-rays that have exactly the optimal energy level. The capability of producing such monoenergetic X-rays has existed for some time. In the past, however, this was possible only with circular particle accelerators with a diameter of several hundred meters. In contrast, the MuCLS is comparable in size to a car.

The data shows that monoenergetic X-rays would make it possible to decrease the required concentration of iodine by about one third with no loss of contrast. For gadolinium, there would even be a somewhat greater reduction. A lot more research is needed, however, before real patients can be examined with monoenergetic X-rays.

"We're still at the very beginning of the development of this technology," said Eggl. The MuCLS is the very first machine of its kind. Moreover, it is designed for fundamental research, and not for examining patients. But with detailed computer simulations and tests with a pig's heart, using blood vessels dyed with iodine, the researchers were able to demonstrate feasibility of the method.

Franz Pfeiffer, professor of biomedical physics at TUM, sees the team's results as a promising start for medical research with the compact synchrotron: "The MuCLS offers numerous possibilities for medical applications that we plan to continue researching with our partners in medical fields,” he said.

The research was funded by the German Research Foundation (DFG), Munich-Centre for Advanced Photonics (MAP) cluster of excellence, the Center for Advanced Laser Applications (CALA), the Ministry for Education and Research, and the DFG Gottfried Wilhelm Leibniz Program.

For more information: www.nature.com/srep

References
Eggl E.,  Mechlem K., Braig E., Kulpe S., et al. "Mono-Energy Coronary Angiography with a Compact Synchrotron Source". Scientific Reports. Published online Feb. 9, 2017. DOI:10.1038/srep42211

Related Content

Voyageur Minerals to Begin Manufacturing Barium Contrast Products With Chief Medical Supply
News | Contrast Media | November 14, 2018
Voyageur Minerals Ltd. signed a joint venture agreement with Chief Medical Supply Ltd (CM) of Calgary, Alberta to...
Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
ContextVision Introduces AI-Powered Image Enhancement for Digital Radiography
Technology | Artificial Intelligence | November 09, 2018
With the integration of deep learning technology, ContextVision takes digital radiography to new levels with its latest...
Siemens Healthineers Announces FDA Clearance of Cios Spin Mobile 3D C-Arm
Technology | Mobile C-Arms | November 06, 2018
Siemens Healthineers announced the U.S. Food and Drug Administration (FDA) clearance of the Cios Spin, a new mobile C-...
Cardiac Ultrasound Software Streamlines Fetal Heart Exams
Feature | Cardiovascular Ultrasound | October 30, 2018
A new tool called fetalHQ on GE Healthcare’s Voluson ultrasound systems is the first tool to simultaneously examine the...
Hitachi Supports ASE Foundation Cardiovascular Outreach Mission in West Virginia
News | Cardiovascular Ultrasound | October 29, 2018
Hitachi Healthcare Americas participated in the cardiovascular screening and diagnostic triage event that took place...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...
Carotid Artery MRI Improves Cardiovascular Disease Risk Assessment
News | Magnetic Resonance Imaging (MRI) | October 23, 2018
Magnetic resonance imaging (MRI) measurements of wall thickness in the carotid arteries improve cardiovascular disease...
CT Offers Non-Invasive Alternative for Complex Coronary Disease Treatment Planning
News | CT Angiography (CTA) | October 16, 2018
A new study published in the European Heart Journal shows computed tomography (CT) can be a useful aid in heart team...

Images from computed tomography (CT) colonography show segmented abdominal aortic calcification measured with semiautomated CT tool on coronal image. Within region of interest over aorta selected by user, tool automatically segments and quantifies aortic calcification (shown in blue). 

Image Credit: O’Connor S D, Graffy P M, Zea R, et al. Does nonenhanced CT-based quantification of abdominal aortic calcification outperform the Framingham Risk Score in predicting cardiovascular event sin asymptomatic adults? Radiology doi: 10.1148/radiol.2018180562. Published online Oct. 2, 2018. © RSNA.

News | Computed Tomography (CT) | October 12, 2018
Computed tomography (CT)-based measures of calcification in the abdominal aorta are strong predictors of heart attacks...