Gonadal Shielding Effectively Minimizes Radiation Dose

Gonadal Shielding Minimizes Radiation Dose, Vivian Fornell

Gonadal shielding (triangular plate) of a toddler undergoing a hip X-ray to reduce the radiation dose to the patient.

January 3, 2017 — The use of a flat contact shield during imaging of the adult male pelvis can result in statistically significant radiation dose reduction to the testes, according to a recent study published in the journal Radiologic Technology.

Conducted by Terri L. Fauber, Ed.D., R.T.(R)(M), a professor emeritus of radiation sciences at Virginia Commonwealth University in Richmond, Virginia, the study shows a 36.4 percent increase in exposure to the testes was calculated when no contact shield was used during pelvic imaging. As a result, Fauber concludes the routine practice of shielding adult male gonads during radiographic imaging of the pelvis should be a best practice for all radiographers.

Fauber first completed a literature review to identify historical trends in shielding radiosensitive organs. The literature review showed a wide disparity of opinions on the use of gonadal shielding. “The effectiveness of gonadal shielding has been a debated topic in clinical practice for many years and it continues today with just as much zeal,” Fauber said. “I was surprised to find the literature also debated the efficacy of gonadal shielding. As a result, I was compelled to further explore the topic.”

To determine whether shielding reduces radiation exposure to the gonads, Fauber used a male anthropomorphic phantom equipped with holes for placement of thermoluminescent dosimeters to correspond to the testes. A flat contact shield was used to shield the phantom’s testes. Ten exposures were made of the pelvis with and without shielding. The exposed TLDs were then analyzed by the University of Wisconsin Calibration Laboratory, which reported the radiation exposure readings for the TLDs with and without shielding.

The study notes that the findings are at odds with previous research that concluded radiation exposure to the testes is not significantly reduced by the use of flat contact shielding. However, Fauber’s findings lend support to a 2010 study that showed that radiation exposure to the testes can be reduced significantly when using a flat contact shield.

“Because there are uncertainties regarding the biologic risks of low-dose radiation exposure, gonadal shields should be consistently utilized and accurately placed,” Fauber said. “In addition it’s good radiation hygiene, especially as our patients become more knowledgeable about potential risks of radiation exposure.”

Fauber said that very little research exists regarding the attitudes of radiologic technologists toward the importance of gonadal shielding and self-reported practices. A large study in the United States on self-reported knowledge about the efficacy of gonadal shielding and its routine practice would provide important information on shielding as a radiation safety practice. Investigating the effectiveness of staff training on the practice of correctly shielding the gonads also would provide valuable information to encourage radiographers to use gonadal shielding routinely.

The study "Gonadal Shielding in Radiography: A Best Practice?" was published in the American Society of Radiologic Technologist journal, Radiologic Technology, November/December 2016, Volume 88, Number 2. 

Related Content

Kubtec Launches New Website For Digital Imaging and Irradiation Products
News | Digital Radiography (DR) | July 20, 2017
Kubtec announced the launch a new website focused on the applications of digital X-ray imaging and irradiation for...
ACR Updates Radiation Oncology and Medical Physics Guidance With ASTRO and AAPM
News | Radiation Dose Management | July 19, 2017
July 19, 2017 — The American College of Radiology (ACR) recently collaborated with professional medical societies to
SafeCT-29 product suite
News | Radiation Dose Management | July 19, 2017
Medic Vision, a pioneer and US market leader in 3rd party XR-29 standard solutions, announced July 19 that it was...
Low Doses of Radiation Could Harm Cardiovascular Health
News | Radiation Dose Management | July 17, 2017
Ionizing radiation, such as X-rays, has a harmful effect on the cardiovascular system even at doses equivalent to...
Agfa HealthCare Previews New DR 800 Imaging System at AHRA 2017
News | Digital Radiography (DR) | July 11, 2017
July 11, 2017 — Agfa HealthCare will display the new DR 800 Multi-Purpose Digital Imaging System with MUSICA for dyna
Canon and Virtual Imaging Inc. Showcase Newest DR Technologies at AHRA 2017
News | Digital Radiography (DR) | July 07, 2017
July 7, 2017 — Canon U.S.A. Inc. and Virtual Imaging Inc., a wholly owned subsidiary of Canon U.S.A.
Fujifilm Showcases Digital Radiography, Mammography Innovations at AHRA 2017
News | Digital Radiography (DR) | July 06, 2017
Fujifilm Medical Systems U.S.A. Inc. will present its comprehensive portfolio of digital radiography (DR) and...
RaySafe Introduces Pro-Slit Camera for Accurate Focal Spot Measurement
Technology | Digital Radiography (DR) | June 27, 2017
Unfors RaySafe recently introduced the RaySafe Pro-Slit Phantom and the RaySafe Pro-Stand.
RadNet Inc. Acquires Equity Stake in Medic Vision
News | Radiation Dose Management | June 21, 2017
June 21, 2017 — RadNet Inc. and Medic Vision Imaging Solutions Ltd.
Diagnostic Radiation Exposure Safe for Children, Experts State
News | Pediatric Imaging | June 21, 2017
In an article published in the June 2017 issue of The Journal of Nuclear Medicine, researchers assert that exposure to...
Overlay Init