Technology | October 14, 2011

FDA Clears GE Discovery MR750w System

October 14, 2011 — GE Healthcare received U.S. Food and Drug Administration (FDA) clearance of the Discovery MR750w wide bore 3.0T system with GEM (Geometry Embracing Method) suite of coils.

This new wide bore 3.0 Tesla magnetic resonance (MR) system addresses patient demand for a better and more comfortable scanning experience. In particular, the new patient-friendly design accommodates patients who are usually difficult to scan; this includes larger, claustrophobic, elderly or very young patients, or those who are in pain and require a larger imaging system.

Additionally, the system combines next-generation clinical applications and a full 50 x 50 x 50 cm field of view. It helps reduce exam time and scan large anatomies with fewer scans, compared to previous generation systems. It also enables higher patient throughput and satisfaction.

The system provides the power of a 3.0T magnet with the open architecture of a 70 cm wide bore. Through fully automated and independent radiofrequency (RF) pulse amplitude and phase control, MultiDrive RF Transmit produces consistently clear 3.0T images.

The system’s gradient and RF performance is optimized to shorten TR’s and TE’s to produce sharp and clear images.

GE’s Optical RF (OpTix) offers high channel count, analog to digital-optical signal conversion inside the scan room to minimize noise and signal degradation but away from the patient to enhance comfort.

Advances in RF coil design are possible through the use of thinner, lightweight, flexible material applicable with a variety of body types, allowing easier patient positioning. Crafted to embrace the patient, these flexible coils make for a more relaxed scan experience. This also makes it easier for technologists to correctly position their patients without strain or difficulty.

The GEM Suite includes a high density GEM Posterior Array embedded within the detachable Express patient table, the Head and Neck Unit with comfort tilt, the Anterior Array, and the Peripheral Vascular/Lower Extremity Array.  Covering 98 percent of all exam types, the coils can be used individually or combined to provide head to toe patient coverage. 

The suite enables automatic configuration that best fits the selected region of interest. It includes a total 205 cm scanning range, feet first or head first scanning for all anatomies, and design features to embrace patients of a wide variety of shapes and sizes.

IDEAL IQ provides a quantitative fat content assessment in the entire liver, while MR Touch is an MR elastography-based imaging technique evaluating tissue stiffness.

For more information: www.gehealthcare.com

 

Related Content

Philips Introduces Technology Maximizer Program for Imaging Equipment Upgrades
Technology | Imaging | January 17, 2018
January 17, 2018 — Philips recently announced the launch of Technology Maximizer, a cross-modality program designed t
Russian Team Developing New Technology to Significantly Reduce MRI Research Costs
News | Magnetic Resonance Imaging (MRI) | January 16, 2018
January 16, 2018 — Researchers from the NUST MISIS Engineering Center for Industrial Technologies in Russia have deve
Smartphone Addiction Creates Imbalance in Brain
News | Mobile Devices | January 11, 2018
Researchers have found an imbalance in the brain chemistry of young people addicted to smartphones and the internet,...
Emergency Radiologists See Inner Toll of Opioid Use Disorders

Rates of Imaging Positivity for IV-SUDs Complications. Image courtesy of Efren J. Flores, M.D.

News | Clinical Study | January 11, 2018
January 11, 2018 – Emergency radiologists are seeing a high prevalence of patients with complications related to opio
Study Finds No Evidence that Gadolinium Causes Neurologic Harm

MR images through, A, C, E, basal ganglia and, B, D, F, posterior fossa at level of dentate nucleus. Images are shown for, A, B, control group patient 4, and the, C, D, first and, E, F, last examinations performed in contrast group patient 13. Regions of interest used in quantification of signal intensity are shown as dashed lines for globus pallidus (green), thalamus (blue), dentate nucleus (yellow), and pons (red).

News | Contrast Media | January 11, 2018
January 11, 2018 — There is no evidence that accumulation in the brain of the element gadolinium speeds cognitive dec
Weight Loss Through Exercise Alone Does Not Protect Knees
News | Orthopedic Imaging | January 11, 2018
January 11, 2018 – Obese people who lose a substantial amount of weight can significantly slow down the degeneration
Neurofeedback Shows Promise in Treating Tinnitus

The standard approach to fMRI neurofeedback. Image courtesy of Matthew Sherwood, Ph.D.

News | Magnetic Resonance Imaging (MRI) | January 11, 2018
January 11, 2018 — Researchers using...
Male Triathletes May Be Putting Their Heart Health at Risk
News | Cardiac Imaging | January 09, 2018
Competitive male triathletes face a higher risk of a potentially harmful heart condition called myocardial fibrosis,...
State-of-the-Art MRI Technology Bypasses Need for Biopsy
News | Magnetic Resonance Imaging (MRI) | January 09, 2018
January 9, 2018 – The most common type of tumor found in the kidney is generally quite small (less than 1.5 in).
New Studies Show Brain Impact of Youth Football
News | Neuro Imaging | January 09, 2018
School-age football players with a history of concussion and high impact exposure undergo brain changes after one...
Overlay Init