52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.

52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.


February 16, 2022—According to an article in ARRS’ American Journal of Roentgenology (AJR), digital breast tomosynthesis (DBT) spot compression view could help characterize equivocal DBT findings, thus reducing further workup for benign findings.

Noting that DBT spot compression increased both intrareader and interreader agreement and improved diagnostic accuracy, primarily from improved specificity, “the view’s supplemental dose was slightly higher than that of a standard DBT view,” corresponding author Foucauld Chamming’s of Institut Bergonié in Bordeaux, France acknowledged.

The all-French team’s retrospective study included 102 women (mean age, 60 years) for whom a DBT spot compression was acquired to characterize an equivocal finding on DBT (via the performing radiologist’s discretion) from December 14, 2018 to December 18, 2019. Conscious of the equivocal lesions’ location, two fellowship-trained breast radiologists and one breast imaging fellow independently reviewed all examinations—assigning an initial BI-RADS category using standard DBT views, immediately followed by a category using DBT spot compression.

Based on kappa coefficients for DBT with and without spot compression views, intrareader agreement increased from 0.43 to 0.72, and interreader agreement increased from 0.21 to 0.45. Additionally, for all three readers, DBT spot compression views yielded significantly increased accuracy, as well as significantly increased specificity.

Adding that their study is the first to evaluate the impact of obtaining DBT spot compression for equivocal findings on DBT, “the results support the utility of spot compression views for aiding evaluation of subtle or ambiguous findings encountered on DBT in clinical practice,” the authors of this AJR article concluded.

For more information: www.arrs.org

Related Digital Breast Tomosynthesis Content:

AI DBT Impact on Mammography Post-breast Therapy

ImageCare Centers Unveils PINK Better Mammo Service Featuring Profound AI

Radiologist Fatigue, Experience Affect Breast Imaging Call Backs

Fewer Breast Cancer Cases Between Screening Rounds with 3-D Mammography


Related Content

News | Breast Imaging

June 20, 2024 — The technologically advanced VELA Mammography Chair, offered by Enable Me, a VELA Medical company ...

Time June 20, 2024
arrow
News | Breast Imaging

June 18, 2024 — Delphinus Medical Technologies, a pioneering medical imaging company that developed the SoftVue Breast ...

Time June 18, 2024
arrow
News | Digital Radiography (DR)

June 12, 2024 — Carestream launched its Image Suite MR 10 Software to help deliver a boost to productivity and ...

Time June 12, 2024
arrow
News | MRI Breast

June 12, 2024 — Royal Philips recently announced the 1,111th installation of its revolutionary BlueSeal 1.5T magnet ...

Time June 12, 2024
arrow
News | Breast Imaging

June 7, 2024 — Scholars and studies funded by Susan G. Komen(R), the world’s leading breast cancer organization ...

Time June 07, 2024
arrow
News | Breast Density

June 6, 2024 — Subsequent rounds of abbreviated breast MRI (AB-MR) screening in patients with dense breasts had lower ...

Time June 06, 2024
arrow
News | Breast Imaging

June 4, 2024 — Using artificial intelligence (AI), breast radiologists in Denmark have improved breast cancer screening ...

Time June 04, 2024
arrow
Feature | Radiology Business | By Melinda Taschetta-Millane

As we flip the page to a new month on our calendars, here is a look at the Top 10 pieces of content viewers were reading ...

Time June 04, 2024
arrow
News | Breast Imaging

May 28, 2024 — iCAD, Inc., a global leader in clinically proven AI-powered cancer detection solutions, announced a ...

Time May 28, 2024
arrow
News | FDA

May 22, 2024 — The U.S. Food and Drug Administration (FDA) has issued a recall of the Hologic Inc. BioZorb marker due to ...

Time May 22, 2024
arrow
Subscribe Now