Technology | November 09, 2008

Automated Coronary Calciums Scoring Detects Plaques Not Found by Agatston Methods

CoronaryScore is a software program for detecting and scoring calcifications in the coronary arteries developed by the medical imaging company Image Analysis Inc.

Study results show technology can detect and score small plaques that are missed by current Agatston-based methods. In an early clinical study, it was found 25 percent of patients with a zero Agatston score in fact had small calcifications in the coronaries detected and scored by the Image Analysis software, the company said.

MDCT coronary artery calcium (CAC) scoring has become important in risk categorization for myocardial infarction and as a screening and staging test for CT angiography. But the technology has traditionally been plagued by a 2 to 5% false negative error for hard coronary events and somewhat lower for significant stenosis.

Using the software images are calibrated with a small cross-sectional calcium hydroxyappatite phantom that is scanned simultaneously with the patient. In addition, it uses the patient’s own blood pool/muscle to standardize the scans in a unique hybrid calibration program. Two scoring thresholds are automatically computed by the software in background mode for the specific patient, scanner, and even specific scan. The thresholds are determined from histogram analysis using statistical computations and variable connectivity criteria based on voxel size and image noise.

The software does not come with a manual, as the company feels it is easy to use and has a system of imbedded, animated help files.

To run the CoronaryScore software, the operator clicks at the origin of the left main artery and then the bifurcation of the LAD/Circ. Then the software automatically segments the heart; performs hybrid calibration; computes the two thresholds and plaque definition criteria; detects the plaques and identifies each to its coronary artery; calculates the calibrated mass score for each plaque, artery, and for the patient; calculates the Agatston and volume scores, either calibrated or not; and the mass plaques are sorted by size and displayed in a distribution graph. The plaque maps and scoring operation allows toggle on/off of the Agatston score and map and toggle on/off of plaque highlights for either Agatston or mass scores.

The automated software provides automated plaque detection and scoring (even with small voxel images) without operator interaction. The software displays them in a viewable 3D plaque map with each plaque shown in three planes and referenced to its exact 3D location in the volume data set. The manufacturer says the automation allows a 160-slice image set to be scored in under three seconds.

November 2008

Related Content

CT Shows Enlarged Aortas in Former Pro Football Players

3-D rendering from a cardiac CT dataset demonstrating mild dilation of the ascending aorta.

News | Computed Tomography (CT) | January 11, 2018
Former National Football League (NFL) players are more likely to have enlarged aortas, a condition that may put them at...
Male Triathletes May Be Putting Their Heart Health at Risk
News | Cardiac Imaging | January 09, 2018
Competitive male triathletes face a higher risk of a potentially harmful heart condition called myocardial fibrosis,...
Toshiba Medical Systems Changes Name to Canon Medical Systems Corp.
News | Business | January 08, 2018
Canon Inc. and Canon Medical Systems Corp. announced the official corporate name (trade name) change of Canon Group...
New International Report Provides Comprehensive Guide to Imaging in Chagas Heart Disease
News | Cardiovascular Ultrasound | January 03, 2018
Chagas disease (ChD), an infectious parasitic disease transmitted primarily by triatomine insects, has become a...
ACR Appropriateness Criteria Adds and Revises Topics for December 2017
News | Clinical Decision Support | December 29, 2017
December 29, 2017 — Radiologists can enhance the quality and effectiveness of care with the newest release of the ACR
BlueCross BlueShield Companies in Eight States Issue Positive Medical Policies for HeartFlow FFRct Analysis
News | CT Angiography (CTA) | December 28, 2017
HeartFlow Inc. announced that Health Care Service Corp. (HCSC), which operates Blue Cross and Blue Shield plans in five...
Siemens Healthineers Strengthens CT Portfolio With Four New Systems at RSNA 2017

The Somatom Force with the new FAST 3-D Camera

Technology | Computed Tomography (CT) | December 14, 2017
Siemens Healthineers introduced four new computed tomography (CT) scanners across two platforms at the 2017...
Toshiba Medical Introduces Aquilion Prime SP CT System at RSNA 2017
Technology | Computed Tomography (CT) | December 13, 2017
Toshiba Medical, a Canon Group company, introduced its new Aquilion Prime SP computed tomography (CT) system at the...
Toshiba Vantage Galan 3T XGO Edition MRI Features New Advanced Gradient

MRI of the brain performed on the Galan 3T utilizing the 32-channel Head SPEEDER Coil

Technology | Magnetic Resonance Imaging (MRI) | December 11, 2017
Toshiba Medical, a Canon Group company, demonstrated the Vantage Galan 3T XGO Edition with the all-new Saturn X...
Toshiba Launches Vantage Elan Zen Edition MR for Enhanced Patient Comfort
Technology | Magnetic Resonance Imaging (MRI) | December 05, 2017
Toshiba Medical, a Canon Group company, introduced its newest magnetic resonance (MR) system, the Vantage Elan/Zen...
Overlay Init