According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental pulmonary embolus (iPE) on conventional contrast-enhanced chest CT examinations had high NPV and moderate PPV, even finding some iPEs missed by radiologists

Left: Axial image shows central nonocclusive filling defect in right lower lobe lateral subsegmental pulmonary artery (arrow). Examination classified positive for iPE by AI but negative for iPE by clinical report. Adjudication process used for reference standard determination classified examination as positive for iPE. Right: Activation map shows location corresponding with iPE identified by AI (arrow). 


July 21, 2022 — According to ARRS’ American Journal of Roentgenology (AJR), an AI tool for detection of incidental pulmonary embolus (iPE) on conventional contrast-enhanced chest CT examinations had high NPV and moderate PPV, even finding some iPEs missed by radiologists. 

“Potential applications of the AI tool include serving as a second reader to help detect additional iPEs or as a worklist triage tool to allow earlier iPE detection and intervention,” wrote lead investigator Kiran Batra from the University of Texas Southwestern Medical Center in Dallas. “Various explanations of misclassifications by the AI tool (both false positives and false negatives) were identified, to provide targets for model improvement.” 

Batra and colleagues’ retrospective study included 2,555 patients (1,340 women, 1,215 men; mean age, 53.6 years) who underwent 3,003 conventional contrast-enhanced chest CT examinations between September 2019 and February 2020 at Parkland Health in Dallas, TX. Using an FDA-approved, commercially available AI tool (Aidoc, New York, NY) to detect acute iPE on the images, a vendor-supplied natural language processing algorithm (RepScheme, Tel Aviv, Israel) was then applied to the clinical reports to identify examinations interpreted as positive for iPE. 

Ultimately, the commercial AI tool had NPV of 99.8% and PPV of 86.7% for detection of iPE on conventional contrast-enhanced chest CT examinations (i.e., not using CT pulmonary angiography protocols). Of 40 iPEs present in the team’s study sample, 7 were detected only by the clinical reports, and 4 were detected only by AI. 

Noting that both the AI tool and clinical reports detected iPEs missed by the other method, “the diagnostic performance of the AI tool did not show significant variation across study subgroups,” the authors of this AJR article added

For more information: arrs.org 


Related Content

News | Information Technology

June 9, 2026 — Mosaic Clinical Technologies, a wholly owned subsidiary of Radiology Partners, has launched Mosaic ...

Time June 15, 2026
arrow
News | Imaging Software Development

June 10, 2026 — DeepHealth, Inc., a wholly owned subsidiary of RadNet, has launched Reporting Pro, an AI-powered ...

Time June 12, 2026
arrow
News | Nuclear Imaging

June 1, 2026 — At the 2026 Society of Nuclear Medicine and Molecular Imaging (SNMMI) annual meeting, GE HealthCare will ...

Time June 02, 2026
arrow
News | Radiopharmaceuticals and Tracers

June 1, 2026 — Serac Healthcare Ltd. has presented Phase 2 data showing that SPECT-CT imaging with the radiotracer 99mTc ...

Time June 01, 2026
arrow
News | Radiopharmaceuticals and Tracers

May 27, 2026 — Subtle Medical has received FDA clearance for its SubtleHD (PET), the company's next-generation AI ...

Time May 27, 2026
arrow
News | FDA

May 19, 2026 — DeepHealth has received the CE Mark for the Brain Health and Brain Age solutions within its Neuro Suite ...

Time May 26, 2026
arrow
News | Cardiac Imaging

May 21, 2026 — A team of researchers from Carnegie Mellon University, in collaboration with Cleveland Clinic’s ...

Time May 22, 2026
arrow
News | X-Ray

May 21, 2026 — RADIN Health and AZmed have announced the expansion of their strategic partnership and enhance radiology ...

Time May 22, 2026
arrow
News | Digital Pathology

May 7, 2026 — Roche has entered into a definitive merger agreement to acquire PathAI, a U.S.-based company in digital ...

Time May 21, 2026
arrow
News | Computed Tomography (CT)

May 12, 2026 – Bracco Imaging S.p.A. has purchased a mobile photon-counting CT scanner from MARS Bioimaging to support ...

Time May 20, 2026
arrow
Subscribe Now