(A) Axial and (B) coronal reformatted images from CT performed with IV contrast material show segmental visualization of main pancreatic duct (arrow). One of three reviewers described main duct dilation as present. Agreement among reviewers on CT for main duct dilatation was substantial (κ=0.63).

March 9, 2022 — According to an open-access Editor’s Choice article in ARRS’ American Journal of Roentgenology (AJR), interobserver agreement proved generally fair to moderate for most CT and MRI findings of chronic pancreatitis in children.

“This study highlights challenges for the imaging diagnosis of pediatric chronic pancreatitis,” wrote first author Andrew T. Trout of Cincinnati Children's Hospital Medical Center in Ohio. “Standardized and/or objective criteria are needed, given the importance of imaging in diagnosis.”

In Trout et al.’s retrospective study, CT or MRI examinations performed in children with chronic pancreatitis were submitted by six sites participating in the INternational Study Group of Pediatric Pancreatitis: In search for a cuRE (INSPPIRE) consortium. One board-certified pediatric radiologist from each of the six sites participated in independent image review. Three radiologists independently reviewed only CT examinations, whereas three other radiologists independently reviewed just MRI examinations. While measuring pancreas thickness and duct diameter, reviewers evaluated 13 categorical subjective features: 12 on both CT and MRI, 1 on CT only, 1 on MRI only.

In this study of six sites in the INSPPIRE consortium, interobserver agreement for findings of chronic pancreatitis in children was relatively high for CT for the presence of parenchymal calcifications (κ=0.81), pancreatic duct dilation (κ=0.63), and atrophy (κ=0.52); and for MRI for main and side branch pancreatic duct findings (κ=0.64-0.74).

Noting that duct findings showed the highest levels of agreement for both modalities, “agreement for subjective findings of atrophy was moderate, and agreement for parenchymal thickness (a quantitative measure of atrophy) depended on the location of measurement, with the best agreement observed in the pancreatic body,” the authors of this AJR article concluded.

For more information: www.arrs.org


Related Content

Feature | Artificial Intelligence | Kyle Hardner

A radiologist pulls up a chest CT scan flagged for a pulmonary nodule. One artificial intelligence (AI) tool writes its ...

Time September 09, 2026
arrow
News | Radiology Business

August 18, 2026 – NewVue, a provider of cloud-native software that unifies how radiologists work while improving ...

Time August 25, 2026
arrow
News | Radiology Imaging

Aug. 13, 2026 — Epic's new Care Everywhere Diagnostic Image Exchange allows health systems using Epic to share ...

Time August 21, 2026
arrow
News | Cardiac Imaging

Aug. 20, 2026 – The novel, radiopaque, polymer-based embolic coil from Embolization, Inc. has now surpassed 125 implants ...

Time August 20, 2026
arrow
Feature | Artificial Intelligence | Madhu Jahagirdar

Radiologists spend much of their day moving between different systems: One application to review images. Another to ...

Time August 17, 2026
arrow
News | X-Ray

Aug. 10, 2026 — Teledyne Technologies Inc. and Varex Imaging Corp. have jointly announced that they have entered into a ...

Time August 14, 2026
arrow
News | Breast Imaging

Aug. 13, 2026 – Perimeter Medical Imaging AI recently announced that Intermountain Health, the largest nonprofit health ...

Time August 14, 2026
arrow
News | FDA

Aug. 1, 2026 — Candelis recently announced that the U.S. Food and Drug Administration (FDA) has granted 510(k) clearance ...

Time August 13, 2026
arrow
News | Cardiac Imaging

August 4, 2026 - ASCEND Cardiovascular and Epsilon Imaging have announced a strategic non-exclusive partnership designed ...

Time August 13, 2026
arrow
News | Artificial Intelligence

Aug. 10, 2026 — OSF HealthCare, a not-for-profit health system serving communities across Illinois and Michigan, and ...

Time August 12, 2026
arrow
Subscribe Now