Role of P3HT MW and polyimide substrate thickness on the functionality of curved X-ray detectors. Loading and unloading P–h curves for the a) NP-BHJ films containing different P3HT MW and b) polyimide substrates of different thicknesses. Misfit strain as a function of both radius of curvature and substrate thickness for NP-BHJ film based on c) P3HT A and d) P3HT D. Misfit strain between the film and substrate increases when thinner substrates and lower P3HT MW are used. Photograph indicating the tendency of

December 29, 2021 — Researchers at the University of Surrey have identified key design rules for making curved X-ray detectors, bringing clearer and safer X-rays a step closer to reality.

Although the use of digital flat panel detectors has enabled radiographers to examine X-rays much more quickly compared with old-fashioned X-ray sensitive photographic films and to make quicker diagnoses, flat panels are ill-suited to the complex shape and geometry of the human body. The reliance purely on flat panels means there is unavoidable distortion around the edges of images. Flat panels also prevent an accurate registration of the X-ray dose delivered, a key feature towards enabling safer radiation therapy and minimizing secondary tumors.

Efforts to create flexible detectors have so far been unsuccessful owing to the brittle characteristics of the rigid inorganic semiconductors used to make them. Some curvature has been achieved through using a thinner layer of semiconductor, but this has compromised performance levels and resulted in poor quality images.

However, in a study published in the peer-reviewed journal Advanced Science, researchers from the Advanced Technology Institute at the University of Surrey, in collaboration with Italy’s University of Bologna, the National Physical Laboratory and Sheffield University, identify design rules for a special class of “inorganic in organic” semiconductors. By tuning the molecular weight of the bismuth oxide nanoparticle sensitised organic semiconductors to lengthen the polymer chains, the researchers are paving the way towards making more robust, curved digital detectors with high sensitivity, or digital film.

Prabodhi Nanayakkara, lead author of the study and PhD student at the University of Surrey, said:

“Our curved detector concept has shown exceptional mechanical robustness and enables bending radii as small as 1.3mm. The use of organic or ‘inorganic in organic’ semiconductors is also far more cost effective than conventional inorganic semiconductors made from silicon or germanium, which require expensive crystal growth methods. Our approach potentially offers a significant commercial advantage.”

Professor Ravi Silva, Director of Surrey’s Advanced Technology Institute, said:

“The technology we’re demonstrating will help create a revolutionary new high sensitivity X-ray detector that is scalable, due to the design and materials adopted. This technology has huge potential in medical applications and other X-ray uses, so we’re working with a spinout company, SilverRay, and hope to turn this technology into the X-ray detector of choice for high sensitivity, high resolution, flexible large area detectors.”

For more information: www.surrey.ac.uk/


Related Content

News | Artificial Intelligence

May 2, 2024 — Radformation, Inc., a leader in automation solutions for cancer care, announced today that it has acquired ...

Time May 02, 2024
arrow
News | Pediatric Imaging

May 2, 2024 — Head and abdominal trauma is a leading cause of death for children. About 1%–2% of children who come to ...

Time May 02, 2024
arrow
News | Prostate Cancer

May 2, 2024 — GT Medical Technologies, Inc. (GT MedTech), a medical device company with the mission of improving the ...

Time May 02, 2024
arrow
Feature | Radiology Business

Beginning this spring, ITN will begin sending out a bi-monthly survey to our readers on a variety of topics, which we ...

Time May 02, 2024
arrow
News | Proton Therapy

April 29, 2024 — Koneksa, a healthcare technology company pioneering evidence-based digital biomarkers, announced today ...

Time April 29, 2024
arrow
News | FDA

April 29, 2024 — The U.S. Food and Drug Administration (FDA) announced Elekta Instrument AB is recalling Disposable ...

Time April 29, 2024
arrow
News | Radiation Dose Management

April 25, 2024 — BIOTRONIK, a leading global medical technology company specializing in innovative cardiovascular and ...

Time April 25, 2024
arrow
News | Magnetic Resonance Imaging (MRI)

April 17, 2024 — Hyperfine, Inc., a groundbreaking health technology company that has redefined brain imaging with the ...

Time April 17, 2024
arrow
News | Radiation Dose Management

April 9, 2024 — Mirion Dosimetry Services, a Mirion Medical company, today announced commercial availability of its ...

Time April 09, 2024
arrow
News | Population Health

April 4, 2024 — A new study found increased coronary vessel wall thickness that was significantly associated with ...

Time April 04, 2024
arrow
Subscribe Now