News | Magnetic Resonance Imaging (MRI) | May 31, 2017

Dutch and Russian researchers say new material can potentially reduce image acquisition time, improve patient comfort and increase image quality

New Metamaterial-Enhanced MRI Technique Tested on Humans

May 31, 2017 — Scientists from the Netherlands and Russia designed and tested a new metasurface-based technology for enhancing the local sensitivity of magnetic resonance imaging (MRI) scanners on humans for the first time. The metasurface consists of thin resonant strips arranged periodically. Placed under a patient's head, it provided much higher signals from the local brain region.

The results, published in Scientific Reports, show that the use of metasurfaces can potentially reduce image acquisition time, thus improving comfort for patients, or acquire higher resolution images for better disease diagnosis.

MRI is a widely used medical technique for examination of internal organs, which can provide, for example, information on structural and functional damage in neurological, cardiovascular, in musculoskeletal conditions, as well as playing a major role in oncology. However, due to its intrinsically lower signal-to-noise ratio, an MRI scan takes much longer to acquire than a computed tomography or ultrasound scan. This means that a patient must lie motionless within a confined apparatus for up to an hour, resulting in significant patient discomfort, and relatively long lines in hospitals.

Specialists from Leiden University Medical Center in the Netherlands and ITMO University in Russia for the first time have acquired human MR-images with enhanced local sensitivity provided by a thin metasurface — a periodic structure of conducting copper strips. The researchers attached these elements to a thin flexible substrate and integrated them with close-fitting receiver coil arrays inside the MRI scanner.

"We placed such a metasurface under the patient's head, after that the local sensitivity increased by 50 percent. This allowed us to obtain higher image and spectroscopic signals from the occipital cortex. Such devices could potentially reduce the duration of MRI studies and improve its comfort for subjects," said Rita Schmidt, the first author of the paper and researcher at the Department of Radiology of Leiden University Medical Center.

The metasurface, placed between a patient and the receiver coils, enhances the signal-to-noise ratio in the region of interest. "This ratio limits the MRI sensitivity and duration of the procedure," noted Alexey Slobozhanyuk, research fellow at the Department of Nanophotonics and Metamaterials of ITMO University. "Often the scans must be repeated many times and the signals added together. Using this metasurface reduces this requirement. Conventionally, if now an examination takes twenty minutes, it may only need ten in the future. If today hospitals serve ten patients a day, they will be able to serve twenty with our development."

Alternatively, according to the scientists, the metasurface could be used to increase the image resolution. "The size of voxels, or 3-D-pixels, is also limited by the signal-to-noise ratio. Instead of accelerating the procedure, we can adopt an alternative approach and acquire more detailed images," said Andrew Webb, the leader of the project, professor of radiology at Leiden University Medical Center.

Until now, no one has shown integration of metamaterials into close-fitting receiver arrays because their dimensions were much too large. The novel ultra-thin design of the metasurface helped to solve this issue.

"Our technology can be applied for producing metamaterial-inspired ultra-thin devices for many different types of MRI scans, but in each case, one should firstly carry out a series of computer simulations as we have done in this work. One needs to make sure that the metasurface is appropriately coupled," concluded Schmidt.

For more information: www.nature.com/srep


Related Content

Feature | Artificial Intelligence | Kyle Hardner

Once considered an adjunct brain cancer therapy and a last-resort treatment, noninvasive radiosurgery has evolved ...

Time March 09, 2026
arrow
News | Artificial Intelligence

March 2, 2026 — RadNet, Inc. has acquired Gleamer SAS, a radiology AI company based in Paris, France. Gleamer will be ...

Time March 03, 2026
arrow
News | HIMSS

March 3, 2026 — MedDream will present its cloud-native, AI-ready universal DICOM viewer in the Amazon Web Services (AWS) ...

Time March 03, 2026
arrow
News

Feb. 26, 2026 — GE HealthCare and UCSF Health have announced a 10-year Care Alliance collaboration focused on ...

Time March 02, 2026
arrow
News | Remote Viewing Systems

Feb. 26, 2026 — DeepHealth, Inc., a provider of AI-powered health informatics and a wholly owned subsidiary of RadNet ...

Time February 27, 2026
arrow
News | Contrast Media

Feb. 23, 2026 — Bracco, a global leader in diagnostic imaging, recently announced that the U.S. Food and Drug ...

Time February 24, 2026
arrow
News | Radiology Imaging

Feb. 12, 2026 — Siemens Healthineers and Mayo Clinic are expanding their strategic collaboration to enhance patient care ...

Time February 13, 2026
arrow
News | Radiology Education

Jan. 22, 2026—The American Roentgen Ray Society (ARRS) will host a live virtual symposium, "Medical Imaging for ...

Time January 28, 2026
arrow
News | Radiology Imaging

Jan.26, 2026 — SimonMed Imaging has unveiled an updated brand and the launch of SimonMed Longevity, a new division ...

Time January 27, 2026
arrow
News | Stroke

Dec. 12, 2025 — Hyperfine, Inc. has announced that it has received FDA clearance for a new multi-direction diffusion ...

Time December 15, 2025
arrow
Subscribe Now