Feature | May 04, 2015 | Dave Fornell

This article appeared as an introduction to a Comparison Chart on PET/CT Systems in the May 2015 issue.

There have been several technology advances in PET/CT (positron emission tomography/computed tomography) systems recently introduced by vendors. On the show floors of the 2014 Society of Nuclear Medicine and Molecular Imaging (SNMMI) meeting and the 2014 Radiological Society of North America (RSNA) meeting, Philips, Toshiba and GE Healthcare introduced new PET/CT systems. You can view the PET/CT Systems comparison chart here.

Philips Vereos First to Offer Digital Detectors

The Philips Vereos is the first PET/CT on the market to offer digital PET detectors, allowing improved image clarity over traditional analog photomultipliers.  The system was first unveiled at RSNA 2013. It uses Philips’ digital photon counting technology in its digital silicon detectors. Philips said this results in a step change in performance that approximately doubles sensitivity gain, volumetric resolution and quantitative accuracy compared to analog systems. These radical improvements can ultimately be translated into high image quality, increased diagnostic confidence, improved treatment planning and faster workflows.

Toshiba’s Celesteion

Toshiba showed its first entry into the molecular imaging market when it unveiled its Celesteion PET/CT. The company hopes to attract buyers with what it describes as the industry’s largest bore, widest field-of-view, dose reduction technology and fast imaging. The bore is 90 cm for CT, 88 cm for PET. Field-of-view is 70 cm for both CT and PET, with an 85 cm CT extended FOV. Dose is minimized through Toshiba’s adaptive iterative dose reduction and Celesteion’s compliance with the Medical Imaging and Technology Alliance’s XR-29 Smart Dose Standard. The new PET/CT offers time-of-flight resolution and 0.5 sec CT rotation with 0.5 mm slices across a 32-slice detector.

Discover IQ

In addition, GE Healthcare introduced its Discovery IQ PET/CT system, which became U.S. Food and Drug Administration (FDA) cleared in September. It enables both high image quality and intelligent quantitation. GE said it delivers the highest NEMA (National Electrical Manufacturers Association) sensitivity (up to 22 cps/kBq) and the largest axial field-of-view (up to 26 cm) compared to other PET/CT equipment. 

GE’s new Q.Clear image reconstruction software is a big component of Discovery IQ, eliminating trade-offs between image quality and quantitative SUV measurements. By providing two times improvement in both quantitative accuracy (SUV mean) and image quality (SNR) in PET/CT imaging, this new tool provides benefits to physicians across the cancer care continuum from diagnosis and staging to treatment planning and assessment.  Over the last decade, PET image reconstruction technology has been designed to provide better image quality, reduced acquisition time and lower injected dose. Current PET iterative reconstruction technologies, such as time of flight (TOF) and ordered-subsets expectation maximization (OSEM), force a compromise between image quality and quantitation, GE said.  

The Discovery IQ uses GE’s new LightBurst detector technology, allowing for whole organ imaging via fast scans at low dose. It also uses fast electronics and a dual acquisition channel that enables high quantitative accuracy for all clinically relevant tracers.

The Discover IQ includes the CortexID software, which aids physicians in the evaluation of patient pathologies via assessment and quantification of PET brain scans. It enables automated analysis through quantification of tracer uptake and comparison with the corresponding tracer uptake in normal subjects. The resulting quantification is presented using volumes of interest, voxel-based or 3-D stereotactic surface projection maps of the brain. The package allows the user to generate information regarding relative changes in PET-FDG glucose metabolism and in PET brain amyloid load between a subject’s images and a normal database, which may be the result of brain neurodegeneration.

Siemens Continuous Motion Bed

In 2013, Siemens Healthcare introduced the Biograph mCT Flow PET/CT system that overcomes the limitations of conventional bed-based PET/CT. It uses Siemens’ FlowMotion technology that moves the patient smoothly through the system’s gantry while continuously acquiring PET data. FlowMotion expands quantification in all dimensions for precise disease characterization in therapy monitoring, while enabling physicians to offer as low as reasonably achievable (ALARA) dose to every patient. The scanner uses a 78 cm bore with five-minute scanning and a continuous sense of progress throughout the scan provides the patient with a more comfortable exam experience.

Conventional PET/CT suffers from intrinsic sensitivity degradation from the center to the edge of the axial FOV. Overlapping sequential bed positions are used to compensate for this constraint, but this approach can lead to axially varying noise sensitivity.  This noise can distort the quantitative values of a detected lesion, which may prompt a physician to mischaracterize the severity of a tumor. By continuously moving the patient through the detection system, FlowMotion technology eliminates overlapping bed acquisitions and maintains uniform noise sensitivity across the entire scan range.


Related Content

News | Radiology Business

Nov. 13, 2025 — Covera Health recently announced that Advanced Radiology Services (ARS) has joined its national Quality ...

Time November 17, 2025
arrow
News | Radiology Business

Nov. 12, 2025 — Siemens has announced plans to deconsolidate its remaining stake in Siemens Healthineers (currently ...

Time November 13, 2025
arrow
News | Radiopharmaceuticals and Tracers

Nov. 11, 2025 — The Society of Nuclear Medicine and Molecular Imaging (SNMMI) has released a position paper outlining ...

Time November 12, 2025
arrow
News | Orthopedic Imaging

Nov.10, 2025 — Medical imaging technology company Adaptix Ltd. has received 510(k) clearance from the U.S. Food and Drug ...

Time November 11, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

Nov. 10, 2025 — There has been substantial progress in the past few years in the field of MRI in general and remote MR ...

Time November 11, 2025
arrow
News | Contrast Media

Nov. 10, 2025 — Scientists at the University of Birmingham have developed a new class of MRI contrast agents – improving ...

Time November 10, 2025
arrow
News | X-Ray

Oct. 30, 2025 – In collaboration with OBIO, University Health Network (UHN), Canada’s leading hospital and the No. 1 ...

Time November 03, 2025
arrow
News | Magnetic Resonance Imaging (MRI) | Children's Hospital Los Angeles

Oct. 28, 2025 — Bronchopulmonary dysplasia (BPD) is the most common — and most serious — complication of extreme ...

Time October 31, 2025
arrow
News | FDA

Oct. 30, 2025 — Sirona Medical has received U.S. Food and Drug Administration (FDA) 510(k) clearance for its Sirona ...

Time October 30, 2025
arrow
Feature | Archive Cloud Storage | Shujah Dasgupta, Vice President, CitiusTech

Almost two-thirds of health systems are already using (or plan to use) the cloud for storing and viewing medical images ...

Time October 30, 2025
arrow
Subscribe Now