News | July 16, 2010

Ultrasound Imaging Agent Launched in India

July 16, 2010 – Lantheus Medical Imaging Inc. this week announced the launch of its ultrasound contrast imaging agent, Definity Vial For (Perflutren Lipid Microsphere) Injectable Suspension, in India.

The company has signed a multiyear agreement with Mumbai-based J.B. Chemicals & Pharmaceuticals Ltd. (JBCPL) for the distribution and marketing of Definity in the Indian marketplace. The launch expands Lantheus’ presence in southern Asia. Definity is currently marketed in North America, Australia and New Zealand, parts of the Pacific Rim, and several countries in the Middle East.

Definity is an ultrasound contrast imaging agent that is indicated in India for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border, as well as for use in patients in contrast-enhanced diagnostic ultrasound imaging to improve characterization of focal lesions of the liver and kidney.

Related Content

Hologic, Inc. announced he U.S. launch of the SuperSonic MACH 40 ultrasound system, expanding the company’s suite of ultrasound technologies with its first premium, cart-based system.
News | Breast Imaging | July 08, 2020
July 8, 2020 — Hologic, Inc. announced he U.S.
Fujifilm’s Sonosite SII POC ultrasound system helps to keep crowded areas clearer with a small ultrasound footprint.

Fujifilm’s Sonosite SII POC ultrasound system helps to keep crowded areas clearer with a small ultrasound footprint.

Feature | Ultrasound Imaging | July 07, 2020 | By Joan Toth
With the miniaturization of technology, improved ease of use, lower system cost, increased portability and greater ac
A 3-D ultrasound system provides an effective, noninvasive way to estimate blood flow that retains its accuracy across different equipment, operators and facilities, according to a study published in the journal Radiology.

Volume flow as a function of color flow gain (at a single testing site). For each row the color flow c-plane and the computed volume flow are shown as a function of color flow gain. The c-plane is shown for four representative gain levels, whereas the computed volume flow is shown for 12–17 steps across the available gain settings. Flow was computed with (solid circles on the graphs) and without (hollow circles on the graphs) partial volume correction. Partial volume correction accounts for pixels that are only partially inside the lumen. Therefore, high gain (ie, blooming) does not result in overestimation of flow. Systems 1 and 2 converge to true flow after the lumen is filled with color pixel. System 3 is nearly constant regarding gain and underestimates the flow by approximately 17%. Shown are mean flow estimated from 20 volumes, and the error bars show standard deviation. Image courtesy of the journal Radiology

News | Ultrasound Imaging | July 01, 2020
July 1, 2020 — A 3-D ultrasound
In new QuickPoLL survey on imaging during the pandemic, responses were tallied from around 170 radiology administrators and business managers, who are part of an imagePRO panel created by The MarkeTech Group (TMTG), regarding the effects of COVID-19 on their business. TMTG is a research firm specializing in the medical device, healthcare and pharmaceutical industries.
Feature | Coronavirus (COVID-19) | June 30, 2020 | By Melinda Taschetta-Millane
The Global Contrast Injectors Market will grow by $613.47M during 2020-2024, according to Technavio
News | Contrast Media Injectors | June 17, 2020
June 17, 2020 — Technavio has been monitoring the ...