Ultrasound-Guided Percutaneous Needle Biopsy ‘Excellent’ for Diagnosing Small Pleural Lesions

Enhanced axial CT (A) shows diffuse pleural thickening (arrow) with a maximum thickness of 3.17 mm. US image for the corresponding lesion on CT (B) shows diffuse pleural thickening (arrowheads) with a maximum thickness of 3.25 mm. The needle pathway length, measured as the needle length through the pleural lesion, was 6.54 mm (asterisk). Pleural puncture angle (exact value not indicated) is depicted as the angle between the outer line of the pleura and the biopsy needle (thin arrow).

Enhanced axial CT (A) shows diffuse pleural thickening (arrow) with a maximum thickness of 3.17 mm. US image for the corresponding lesion on CT (B) shows diffuse pleural thickening (arrowheads) with a maximum thickness of 3.25 mm. The needle pathway length, measured as the needle length through the pleural lesion, was 6.54 mm (asterisk). Pleural puncture angle (exact value not indicated) is depicted as the angle between the outer line of the pleura and the biopsy needle (thin arrow).

Enhanced axial CT (C) shows nodular pleural thickening (arrows). US image for the corresponding lesion on CT (D) shows nodular pleural morphology (arrowheads). Distance from skin to pleura, measured as the perpendicular distance between the skin and the pleural puncture site, was 14.04 mm.

Enhanced axial CT (C) shows nodular pleural thickening (arrows). US image for the corresponding lesion on CT (D) shows nodular pleural morphology (arrowheads). Distance from skin to pleura, measured as the perpendicular distance between the skin and the pleural puncture site, was 14.04 mm.

November 9, 2020 — According to an open-access article in ARRS’ American Journal of Roentgenology (AJR), ultrasound (US)-guided percutaneous pleural needle biopsy (PCPNB) has excellent diagnostic accuracy for small pleural lesions.

“US-guided PCPNB is highly likely to be diagnostic for small pleural lesions with nodular morphology on CT or US, or with pleural thickness ≥ 4.5 mm,” explained Jongmin Park and colleagues from South Korea’s Kyungpook National University.

To determine the diagnostic yield of US-guided PCPNB for small (≤ 2 cm) pleural lesions and the impact of computed tomography (CT) and US morphologic and technical factors, Park’s team retrospectively studied 103 patients (73 men, 30 women; mean age, 60.8) who underwent US-guided PCPNB of a small pleural lesion by a single experienced operator from July 2013 to December 2019. Histopathological results established final diagnosis, including from repeat US-guided and CT-guided biopsies, as well as imaging and clinical follow-up. CT and US assessed pleural morphology and thickness, while US measured needle pathway length throughout the pleura.

Summarizing their results, Park et al. noted: “[US-guided PCPNB] of small pleural lesions had a diagnostic accuracy of 85.4%. The yield was 96.4% for nodular CT lesions, 95.0% for diffuse CT lesions with thickness ≥4.5 mm, 55.6% for diffuse CT lesions with thickness.”

Repeating their assessments on both CT and US 2 weeks later yielded the representative measurements as shown in the images.

“In multivariable analysis,” the authors of this AJR article concluded, “pleural morphology on US and needle pathway length through the pleura independently predicted diagnostic yield,” adding that if the pleura is nodular or thicker than 4.5 mm on CT, US-guided PCPNB is justifiable as an initial or repeat diagnostic test.

For more information: www.arrs.org

Related Content

Right mediolateral oblique (MLO) mammograms for different women with the same breast thickness but varying breast density.

Right mediolateral oblique (MLO) mammograms for different women with the same breast thickness but varying breast density.

News | Breast Imaging | July 30, 2021
July 30, 2021 — Volpara Health, a global health technology software leader providing an integrated breast care platfo
According to ARRS’ American Journal of Roentgenology (AJR), the resources required to warm iohexol 350 to body temperature before injection for computed tomography (CT) may not be warranted, given the lack of observed practical benefit.

Values represent number of patients, with percentage in parentheses and 95% CI in brackets (not reported for levels of severity of allergic/allergic-like reactions). 95% CIs were calculated using the Clopper-Pearson exact formula. For events with zero frequency, one-sided 97.5% CIs are provided.

News | Contrast Media | July 30, 2021
Images, or a digital twin mitral valve of a patient, created from cardiac ultrasound that were used to perform a virtual surgical procedure to test how the intervention would impact the patient prior to actually performing the procedure. The right image shows color coding for sheer stresses on the valve leaflets before and after the virtual surgery. The left image shows the model quantitation of leaflet coaptation at peak systole prior to the the virtual surgery.

Images, or a digital twin mitral valve of a patient, created from cardiac ultrasound that were used to perform a virtual surgical procedure to test how the intervention would impact the patient prior to actually performing the procedure. The right image shows color coding for sheer stresses on the valve leaflets before and after the virtual surgery. The left image shows the model quantitation of leaflet coaptation at peak systole prior to the the virtual surgery. Read the original article in Plos One.

Feature | Ultrasound Imaging | July 28, 2021
Outside of medicine, computer-generated virtual twins of real machines like cars or airplanes have been used in engin
If you plan to attend HIMSS21 Aug. 9-13 in Las Vegas, be sure to note that due to health and safety updates, masks will now be required for attendees and exhibitors.

Getty Images

News | HIMSS | July 28, 2021
July 28, 2021 —If you plan to attend HIMSS21 Aug.
Researchers from the School of Biomedical Engineering & Imaging Sciences at King's College London have automated brain MRI image labeling, needed to teach machine learning image recognition models, by deriving important labels from radiology reports and accurately assigning them to the corresponding MRI examinations

Getty Images

News | Magnetic Resonance Imaging (MRI) | July 28, 2021
July 28, 2021 — Researchers from the School of Biomedical Engineering & Imaging Sciences at...
A new Harvey L. Neiman Health Policy Institute study found that patients paid 12% of the costs of secondary imaging interpretation out-of-pocket. Such secondary interpretations are increasingly performed for complex patients, but patients’ liabilities and paid out-of-pocket costs were not previously known.

Getty Images

News | Radiology Imaging | July 28, 2021
July 28, 2021 — A new Harvey L.