News | April 21, 2009

Tomotherapy Shows Prostate Motion Affects Target Dose Only Slightly

April 21, 2009 – In a study in which researchers from the MD Anderson Cancer Centre Orlando, FL, and the University of Wisconsin, Madison, conducted an analysis of prostate motion during helical tomotherapy, they concluded that the impact on target dose is actually quite small (Int. J. Rad. Oncol. Biol. Phys. doi: 10.1016/j.ijrobp.2008.09.035).

The study marked the first time that helical tomotherapy has been considered in similar detail. Researchers used electromagnetic markers by Calypso Medical Technologies to track prostate motion. Three markers were implanted under ultrasound guidance in 16 patients who went on to receive IMRT. Tomotherapy treatment plans were generated retrospectively and compared with motion tracks from the markers.

Two separate scenarios were considered. The first assumed that treatment started at the beginning of the observation period. The second anticipated an estimated delay of five minutes between patient alignment and the start of treatment. The minimum dose (Dmin), maximum dose (Dmax) and dose to 95 percent of the volume (D95 percent) were calculated for the whole prostate and for the planning target volume (PTV). These values were then compared with the doses that would have been delivered had the prostate stayed still. The cumulative effect was also evaluated over the course of treatment.

The results showed that for individual fractions, target D95 percent could be reduced by as much as 20 percent. However, the effect of such sizeable dose reductions diminished quickly as treatment continued. The effect on target D95 percent was less than 1 percent by the time that five fractions had been delivered. The biggest surprise was the similarity in observed changes to D95 percent for the prostate and the PTV.

While the results only apply to whole-prostate tomotherapy, researchers will test other techniques that may be affected more by organ motion, such as dose-painting, in a follow-up study.

For more information: www.redjournal.org

Related Content

Sponsored Content | Videos | Proton Therapy | August 21, 2017
Mark Pankuch, Ph.D., director of medical physics at the Northwestern Medicine Chicago Proton Center, discusses the cl
Summit Cancer Center-Boise Treats First Cancer Patients With Accuray Radixact System
News | Image Guided Radiation Therapy (IGRT) | August 21, 2017
Accuray Inc. and the Summit Cancer Center-Boise announced that the center is now treating patients with the Radixact...
MedStar Georgetown Proton Center Selects RayStation for Treatment Planning
News | Treatment Planning | August 17, 2017
August 17, 2017 — The proton center at MedStar Georgetown University Hospital will utilize RayStation for planning on
DOSIsoft Releases ISOgray Proton Therapy Treatment Planning System
Technology | Treatment Planning | August 15, 2017
DOSIsoft SA announced the official release, with CE marking, of ISOgray Treatment Planning System (TPS) release 4.3 for...
First Radixact Results Presented at AAPM 2017
News | Radiation Therapy | August 10, 2017
Accuray Inc. announced that the first studies validating the benefits of the Radixact System were presented at the 59th...
Clinical Data Supports Use of Xoft System for Endometrial Cancer
News | Brachytherapy Systems | August 03, 2017
Researchers presented clinical data supporting use of the Xoft Axxent Electronic Brachytherapy (eBx) System for the...
Aktina’s interchangeable cones are lightweight and extremely accurate
News | Radiation Therapy | August 02, 2017
Aktina Medical announced a collaboration with Philips Medical Systems and Elekta Instruments for SRS interlocking at...
News | Image Guided Radiation Therapy (IGRT) | July 31, 2017
Elekta’s magnetic resonance radiation therapy (MR/RT) system will be the subject of 21 abstracts at the 59th American...
Accuray Receives 510(k) Clearance for iDMS Data Management System
Technology | Oncology Information Management Systems (OIMS) | July 31, 2017
July 31, 2017 — Accuray Inc. announced it has received 510(k) clearance from the U.S.
Overlay Init