News | Electronic Medical Records (EMR) | July 18, 2018

Study Points to Need for Performance Standards for EHR Usability and Safety

Researchers find huge variability in task completion efficiency and accuracy

Study Points to Need for Performance Standards for EHR Usability and Safety

July 18, 2018 —A novel new study provides compelling evidence that the design, development and implementation of electronic health records (EHRs) need to be improved to make them easier to use by clinicians and, ultimately, safer for patients.

The study, entitled “A usability and safety analysis of electronic health records: a multi-center study,” was published July 2 by the Journal of the American Medical Informatics Association.  It was conducted by researchers with MedStar Health’s National Center for Human Factors in Healthcare, the American Medical Association (AMA) and others, and was funded by the AMA. Researchers focused on the two largest EHR vendors, Epic and Cerner, who comprise more than 50 percent of the market. They conducted the study at two sites per vendor, or four health systems.

Twelve to 15 emergency physicians per site were given common tasks mimicking real patient cases—placing orders for medical imaging, lab tests and medications. Researchers collected data pertaining to length of time and number of clicks to complete each task plus the degree of accuracy. The findings showed huge variability in performance across the sites. For example, time to complete an imaging order varied from 25 seconds at one site to more than a minute at another. Placing an imaging order required an average of eight clicks at one site, while the same task at a different site averaged 31. For a medication order, one site recorded no errors while another had a 30 percent error rate.

“While there are many benefits to using EHRs, there are also usability and safety challenges that can lead to patient harm,” said the study’s lead author Raj Ratwani, Ph,D,, center director and scientific director of the MedStar Human Factors Center, and a leading researcher of EHR safety and usability.

To have their products certified, EHR vendors are required by the federal government to employ user-centered design as they develop systems and to conduct usability testing near the end of the process. But EHR usability challenges persist due to several reasons outlined in the study. One large factor is that EHRs are configured and customized by the vendor and health system during implementation, and the resulting product may be significantly different from the one that was tested by the vendor to meet government requirements for usability and safety.

“Our findings reaffirm the importance of considering patient care and physician input in the development and implementation of EHRs,” said study co-author Michael Hodgkins, M.D., chief medical information officer of the AMA. “There are multiple variables impacting the end-user experience that contribute to physician burnout, a diminished patient-physician relationship and unrealized cost savings. While design can be an important factor, so too can implementation choices made onsite. Increased collaboration between vendors, information technology purchasers and physicians is needed to optimize experiences and address current needs.”

The study’s authors conclude, “Our results suggest that basic performance standards for all implemented EHRs should be considered in order to ensure usable and safe systems. Both EHR vendors and providers should work together to ensure that usable and safe products are implemented and used.”

Study authors are:

  • Raj M. Ratwani, Ph.D.;
  • Erica Savage, MS;
  • Amy Will;
  • Ryan Arnold, M.D.;
  • Saif Khairat, Ph.D.;
  • Kristen Miller, DrPH;
  • Rollin J.”Terry” Fairbanks, M.D.;
  • Michael Hodgkins, M.D.; and
  • A. Zachary Hettinger, M.D.

For more information: www.academic.oup.com/jamia

Reference

Ratwani R.J., Savage E., Will A., et al. "A usability and safety analysis of electronic health records: a multi-center study." Journal of the American Medical Informatics Association, July 2, 2018. https://doi.org/10.1093/jamia/ocy088

 

Related Content

Nuance Launches Cloud-Based mPower Clinical Analytics Platform at AHRA 2018
Technology | Analytics Software | August 16, 2018
At the Association for Medical Imaging Management (AHRA) 2018 Annual Meeting and Exposition, July 22-25 in Orlando, Fla...
Doctor-Patient Discussions Neglect Potential Harms of Lung Cancer Screening
News | Lung Cancer | August 15, 2018
August 15, 2018 — Although national guidelines advise doctors to discuss the benefits and harms of...
Intel and Philips Demonstrate CPU Ability in Deep Learning Inference Test Cases
News | Artificial Intelligence | August 15, 2018
Intel and Philips recently tested two healthcare uses for deep learning inference models using Intel Xeon Scalable...
Guerbet Partners With Imalogix on Dose Optimization With Artificial Intelligence
News | Radiation Dose Management | August 14, 2018
August 14, 2018 — Guerbet LLC USA announced a commercial partnership with Imalogix, a provider of...
Visage Signs Mercy for Visage 7 Open Archive
News | Enterprise Imaging | August 09, 2018
Visage Imaging Inc. announced that it has signed a seven-year contract with Mercy, the fifth largest Catholic health...
Videos | Radiomics | August 09, 2018
A discussion with Martin Vallieres, Ph.D., post-doctoral fellow at McGill University, Montreal, Canada.
Aidoc Receives FDA Clearance for AI Detection of Acute Intracranial Hemorrhage
Technology | Clinical Decision Support | August 08, 2018
Aidoc announced that it was granted U.S. Food and Drug Administration (FDA) clearance for the first product of its...
Cardiac Imaging Reveals Roots of Preeclampsia Damage in Pregnant Women
News | Women's Health | August 07, 2018
Johns Hopkins researchers say a heart imaging study of scores of pregnant women with the most severe and dangerous form...
Metro Health-University of Michigan Health Partners With Eon to Improve Lung Cancer Care
News | Oncology Diagnostics | August 07, 2018
Metro Health-University of Michigan Health announced it is partnering with healthcare data company Eon to improve the...
Cardiac Monitoring a Higher Priority for High-Risk Breast Cancer Patients
News | Cardio-oncology | August 07, 2018
August 7, 2018 — While heart failure is an uncommon complication of...
Overlay Init