News | January 29, 2009

Sequential, Alternating Chemo Equal to RT in Larynx Cancer

January 29, 2009 - Larynx cancer patients treated with alternating cycles of chemotherapy and radiation have similar outcomes to patients treated with chemotherapy followed by radiation, according to data from a randomized controlled trial in the Jan. 27 online issue of the Journal of the National Cancer Institute.

Previous trials in patients with locally advanced larynx cancer showed that chemotherapy followed by radiation was as effective as total removal of the larynx, known as laryngectomy, in terms of overall and disease-free survival and that this sequential therapy provided better quality of life. Subsequent trials indicated that concurrent administration of chemotherapy and radiation resulted in a statistically significant improvement in larynx preservation but was associated with more serious acute toxicity and possibly long term side effects.

To try to improve patient survival without increasing side effects, Jean Lefebvre, M.D., of the Centre Oscar Lambret in Lille, France, and colleagues in the European Organization for Research and Treatment of Cancer enrolled 450 patients with larynx or hypopharynx cancer in a randomized controlled trial. Patients received either chemotherapy followed by radiation or alternating cycles of radiation and chemotherapy.

With a median follow-up of 6.5 years, there was no significant difference in clinical outcomes between the two treatment groups. Larynx preservation, overall survival, and progression-free survival were similar for patients treated with sequential and alternating chemotherapy and radiation.

"The aim of our trial was to identify a regimen that would mimic concomitant chemotherapy and radiotherapy without its increased toxic effects," the authors write. "Although we achieved the latter goal…efficacy was not improved." Given the results of this and several other recently-completed trials, the authors conclude that an optimal approach for larynx-preserving therapy has not been identified.

In an accompanying editorial, Arlene Forastiere, M.D., and Andy Trotti, M.D., of the Sidney Kimmel Cancer Center at Johns Hopkins University in Baltimore and the H. Lee Moffitt Cancer Center at the University of South Florida in Tampa, respectively, concur with that conclusion. The editorialists put the newly-reported data into context, reviewing other trials in the field. They note, however, that because the field currently lacks shared definitions and endpoints, synthesis of data from all the trials is difficult.

"In summary, the [current] trial showed no advantage for alternating chemotherapy and radiotherapy over traditional cisplatin plus 5-fluorouracil induction chemotherapy in hypopharynx cancer," the editorialists write. "More effective and less toxic approaches are needed. This trial also illustrates the need for common definitions and metrics to facilitate interpretation and to compare results across trials."

For more information: jnci.oxfordjournals.org

Related Content

Mevion Receives 510(k) Clearance for Hyperscan Pencil Beam Scanning Proton Therapy
Technology | Proton Therapy | January 04, 2018
Mevion Medical Systems has received U.S. Food and Drug Administration (FDA) 510(k) clearance for the Mevion S250i...
Study Compares Radiosurgery and Whole-Brain Radiation in Lung Cancer Patients With Multiple Brain Metastases
News | Radiation Therapy | January 03, 2018
Although targeted therapies have produced dramatic advances in the ability to control some types of advanced lung...
MEDraysintell Downgrades Proton Therapy Market Projection for 2030
News | Proton Therapy | January 02, 2018
MEDraysintell recently downgraded its projection for proton therapy rooms expected to be operational in 2030 from 1,200...
California US Oncology Network Centers Adopt Xoft Electronic Brachytherapy System for Early-Stage Non-Melanoma Skin Cancer
News | Brachytherapy Systems | January 02, 2018
iCAD Inc. announced that its Xoft Axxent Electronic Brachytherapy (eBx) System is now available at two California-based...
Blue Phantom System Used for Acceptance of First European Varian Halcyon Machine
News | Radiation Therapy | January 02, 2018
IBA (Ion Beam Applications S.A.) announced in November the acceptance and beam model validation of the first Varian...
Study Finds Link Between Breast Cancer Treatments and Cellular Aging Markers
News | Women's Health | January 02, 2018
January 2, 2018 — A new study found women who had received chemotherapy and/or...
ACR Appropriateness Criteria Adds and Revises Topics for December 2017
News | Clinical Decision Support | December 29, 2017
December 29, 2017 — Radiologists can enhance the quality and effectiveness of care with the newest release of the ACR
FDA Clears GammaPod Stereotactic Radiotherapy System for Breast Cancer Treatment
Technology | Stereotactic Body Radiation Therapy (SBRT) | December 22, 2017
The U.S. Food and Drug Administration (FDA) has cleared the new GammaPod noninvasive stereotactic radiotherapy system...
RaySearch Launches RayCare Oncology Information System

Image courtesy of RaySearch Laboratories

Technology | Oncology Information Management Systems (OIMS) | December 22, 2017
RaySearch announced the first release of RayCare, a new oncology information system (OIS) designed to connect the...
RaySearch Releases RayStation 7 Radiotherapy Treatment Planning System
Technology | Treatment Planning | December 19, 2017
RayStation 7, the latest release of RaySearch’s radiation therapy treatment planning system, adds new functionality and...
Overlay Init