News | March 26, 2012

MRI Techniques Improve Pulmonary Embolism Detection

March 26, 2012 - New research shows that the addition of two magnetic resonance imaging (MRI) sequences to a common MR angiography technique significantly improves detection of pulmonary embolism, a potentially life-threatening condition traditionally diagnosed through computed tomography (CT). Results of the study are published online in the journal Radiology.

Pulmonary embolism occurs when a blood clot — usually from the leg — travels to the lung and blocks the pulmonary artery or one of its main branches. CT angiography is the gold standard for diagnosis, but it exposes patients to ionizing radiation and iodinated contrast agent, which carries a risk of allergic reactions and kidney damage in some patients.

“MRI is developing much faster than CT,” said Diego R. Martin, M.D., Ph.D., head of the Department of Radiology at the University of Arizona College of Medicine in Tucson. “The images we're getting are already significantly better than they were a year ago. There is no doubt that in the future we will be able to offer a non-radiation-based alternative to CT for the diagnosis of pulmonary embolism.”

MRI has been used for pulmonary embolism detection in pregnant women and patients whose kidneys may be harmed by CT angiography contrast agents. However, the Prospective Investigation of Pulmonary Embolism Diagnosis III (PIOPED III) study, a major multi-center trial, found that centers had difficulty obtaining adequate quality MR pulmonary angiography (MRPA) for suspected pulmonary embolism. The PIOPED researchers determined that MRPA should be considered only at centers that routinely perform it and perform it well, and for patients who have contraindications to standard tests.         

In the new study, the research team assessed the impact of two additional MRI sequences on MRPA's accuracy. The two techniques—contrast-enhanced volumetric interpolated breath-hold examination (VIBE) and non-contrast true fast imaging with steady-state precession (true FISP)—complement MRPA, according to Martin.

The addition of VIBE provides a gray scale that enables readers to distinguish between the clot, or thrombus and the lung, which both appear dark on MRPA. 

“Also, VIBE is not time sensitive,” Martin said. “If the patient coughs, you can do it again. You don't have that option with MRPA.”

The true FISP test does not require contrast agent or a breath hold, an important consideration for embolism patients who often cannot hold their breath long enough for image acquisition on MRPA.

When Martin and his colleagues studied the three techniques on 22 patients with CTA diagnosis of pulmonary embolism, they found a sensitivity of 55 percent, 67 percent and 73 percent for MRPA, true FISP and VIBE, respectively. Combining all three MRI sequences improved the overall detection rate to 84 percent. Specificity was 100 percent for all detection methods except for MRPA, which demonstrated one false positive.

Martin hopes his findings stimulate discussion of a new, redesigned PIOPED study.

“PIOPED III did not answer the question of whether or not MRI is a useful alternative to CT, because it didn't use all the tools available,” he said.

The MRI sequences used in the study are offered on all the major vendor systems, according to Martin, with the entire three-sequence protocol taking only 15 minutes to set up and perform.

For more information: radiology.rsna.org

 

Related Content

Philips Introduces Technology Maximizer Program for Imaging Equipment Upgrades
Technology | Imaging | January 17, 2018
January 17, 2018 — Philips recently announced the launch of Technology Maximizer, a cross-modality program designed t
Russian Team Developing New Technology to Significantly Reduce MRI Research Costs
News | Magnetic Resonance Imaging (MRI) | January 16, 2018
January 16, 2018 — Researchers from the NUST MISIS Engineering Center for Industrial Technologies in Russia have deve
Transpara Deep Learning Software Matches Experienced Radiologists in Mammogram Reading
News | Computer-Aided Detection Software | January 12, 2018
Deep learning and artificial intelligence improves the efficiency and accuracy of reading mammograms, according to...
Fat Distribution in Women and Men Provides Clues to Heart Attack Risk
News | Women's Health | January 11, 2018
January 11, 2018 – It’s not the amount of fat in your body but where it is stored that may increase your risk for hea
Smartphone Addiction Creates Imbalance in Brain
News | Mobile Devices | January 11, 2018
Researchers have found an imbalance in the brain chemistry of young people addicted to smartphones and the internet,...
Emergency Radiologists See Inner Toll of Opioid Use Disorders

Rates of Imaging Positivity for IV-SUDs Complications. Image courtesy of Efren J. Flores, M.D.

News | Clinical Study | January 11, 2018
January 11, 2018 – Emergency radiologists are seeing a high prevalence of patients with complications related to opio
Minimally Invasive Treatment Provides Relief from Back Pain

Lumbar spine MRI showing disc herniation and nerve root at baseline and one month after treatment

News | Interventional Radiology | January 11, 2018
The majority of patients were pain free after receiving a new image-guided pulsed radiofrequency treatment for low back...
CT Shows Enlarged Aortas in Former Pro Football Players

3-D rendering from a cardiac CT dataset demonstrating mild dilation of the ascending aorta.

News | Computed Tomography (CT) | January 11, 2018
Former National Football League (NFL) players are more likely to have enlarged aortas, a condition that may put them at...
Study Finds No Evidence that Gadolinium Causes Neurologic Harm

MR images through, A, C, E, basal ganglia and, B, D, F, posterior fossa at level of dentate nucleus. Images are shown for, A, B, control group patient 4, and the, C, D, first and, E, F, last examinations performed in contrast group patient 13. Regions of interest used in quantification of signal intensity are shown as dashed lines for globus pallidus (green), thalamus (blue), dentate nucleus (yellow), and pons (red).

News | Contrast Media | January 11, 2018
January 11, 2018 — There is no evidence that accumulation in the brain of the element gadolinium speeds cognitive dec

Size comparison between 3-D printed prosthesis implant and a penny.

News | 3-D Printing | January 11, 2018
January 11, 2018 — Researchers using...
Overlay Init