Technology | October 26, 2008

GE Introduces New Signa 3.0T MR with 60 Percent More Coverage

GE Healthcare says it is breaking the bonds of traditional magnetic resonance scanning with the introduction of its latest MR scanner, the Signa MR750 3.0T.

Equipped with powerful gradients, easy-to-use workflow features and the company’s advanced Thermal Management System, the Signa MR750 delivers up to 60 percent additional anatomical coverage and resolution unit per time. The system also allows for up to five times the imaging performance over previous generations, increasing the freedom for advanced application development.

Relevant clinical applications include LAVA-Flex, a dual-echo acquisition technique that raises the bar on existing sequences to provide consistent, detailed, three-dimensional abdominal images in one breathhold. In addition, LAVA-Flex produces in one scan four different contrasts, allowing the user to select the output image types - in-phase, opposed-phase, water, and fat. With this new application, clinicians can now conduct a complete liver exam in 15 minutes.

LAVA- Flex offers ‘fat only’ and ‘water only’ images in addition to high quality in-phase and opposed-phase images in a single breathhold, a sequence that has quickly become a routine part of all our abdominal sequence protocols at 3.0T, according to Elmar Merkle, M.D., professor of Radiology, Head of Body Magnetic Resonance Imaging and Medical director of the Center for Advanced Magnetic Resonance Development at Duke University.

VIBRANT- Flex is a new application that allows for fat-free breast imaging with high spatio-temporal resolution. This application catches the shortest in- and out-of phase echoes to keep scan times comparable to single echo acquisitions, even though twice the amount of data is collected.

VIBRANT Flex optimizes acquisition with a high signal-to-noise ratio (SNR) for acquiring high quality water and fat images. This capability lets the user prescribe thinner slices for high spatial resolution imaging.

PROPELLER 2.0 enables strong performance in reportedly all imaging planes with the implementation of the No Phase Wrap (NPW) technique. NPW allows virtually ghost-artifact-free, motion-immune scans in sagittal, coronal, axial and oblique planes. Since this technique effectively deals with the aliasing artifact, PROPELLER 2.0 is now more robust performing small field-of-view (FOV) scans.

With GE-exclusive 3D SWAN technique, you can capture and delineate small vessels and microbleeds as well as large vascular structures and iron and calcium depositions in the brain. 3D SWAN's unique, multi-echo acquisition technique and postprocessing algorithm provide wider tissue bandwidth, 2-4 times more SNR and more contrast in a simple to use, robust package within clinically relevant scan times. With such broad clinical properties, 3D SWAN may aid clinicians in diagnosing among others patients with ischaemic and cerebral brain diseases, arteriovenous malformations and neurodegenerative diseases.

Related Content

Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
Subtle Medical Showcases Artificial Intelligence for PET, MRI Scans at RSNA 2018
News | Artificial Intelligence | November 13, 2018
At the 2018 Radiological Society of North America annual meeting (RSNA 2018), Nov. 25-30 in Chicago, Subtle Medical...
This is the Siemens Magnetom Sola RT edition 1.5T MRI system optimized for radiation therapy displayed for the first time since gaining FDA clearance in 2018. It was displayed at the American Society for Radiotherapy and Oncology (ASTRO) 2018 annual meeting. Read more about this system at ASTRO 2018. #ASTRO18 #ASTRO2018
360 Photos | 360 View Photos | November 07, 2018
This is the Siemens Magnetom Sola RT edition 1.5T MRI system optimized for...
Fans of Opposing Soccer Teams Perceive Games Differently

Image courtesy of University of York

News | Neuro Imaging | October 25, 2018
Scientists have scanned the brains of die-hard soccer fans to find out why supporters of rival teams often have very...
IMRIS, Siemens Strengthen Collaboration in Hybrid OR Neurosurgical Market
News | Hybrid OR | October 24, 2018
IMRIS, Deerfield Imaging, in partnership with Siemens Healthineers, announced a strengthened collaboration to advance...
Carotid Artery MRI Improves Cardiovascular Disease Risk Assessment
News | Magnetic Resonance Imaging (MRI) | October 23, 2018
Magnetic resonance imaging (MRI) measurements of wall thickness in the carotid arteries improve cardiovascular disease...
The Elekta Unity with 1.5T MRI embedded as a targeting system appeared at the annual meeting of the American Society of Radiation Oncology (ASTRO) in San Antonio, Texas. The system is being sold in Europe and could soon enter the U.S. marketplace. (Photo courtesy of Elekta)

The Elekta Unity with 1.5T MRI embedded as a targeting system appeared at the annual meeting of the American Society of Radiation Oncology (ASTRO) in San Antonio, Texas. The system is being sold in Europe and could soon enter the U.S. marketplace. (Photo courtesy of Elekta)

Feature | ASTRO | October 20, 2018 | By Greg Freiherr
A linear accelerator combined with high-field MRI could soon be on the U.S. market. If U.S.
FDA Clears Magnetom Sola 1.5T MRI From Siemens Healthineers
Technology | Magnetic Resonance Imaging (MRI) | October 09, 2018
The U.S. Food and Drug Administration (FDA) has cleared the Magnetom Sola, a 1.5 Tesla magnetic resonance imaging (MRI...