November 14, 2013 — A University of Colorado Cancer Center study, published in the journal Physics in Medicine and Biology, shows that endorectal balloons commonly used during precise radiation treatment for prostate cancer can deform the prostate in a way that could make radiation miss its mark.
 
“Use of a balloon allows you to stabilize the anatomy,” said Moyed Miften, Ph.D, FAAPM, investigator, University of Colorado Cancer Center and chief physicist, department of radiation oncology, University of Colorado School of Medicine. “But what we show is that imprecision with balloon placement could reduce radiation dose coverage over the intended area.”
 
Specifically, Miften and colleagues studied the technique known as stereotactic body radiation, in which powerful, precisely-targeted radiation is delivered only to cancerous areas of the prostate with the hope of killing tumor tissue. An endorectal balloon is needed to hold the prostate in place while this high dose is delivered. The study used 71 images of nine patients to show an average endorectal balloon placement error of 0.5 cm in the inferior direction. The placement errors led to less precise radiation targeting and to uneven radiation dose coverage over cancerous areas.
 
“In radiation oncology, we use a CT (computed tomography) scan to image a patient’s prostate and then plan necessary treatment,” said Miften. “But if during treatment the prostate doesn’t match this planning image, we can deliver an imprecise dose.”
 
With the use of endorectal balloon, Miften and colleagues found prostates could be slightly pushed or squeezed, resulting in the prostate deforming slightly from its original shape and also sometimes tilting slightly from its original position in the body. These deformations can push parts of the prostate outside the area reached by the planned radiation.
 
“What we see is that whether or not a clinician chooses to use an endorectal balloon along with stereotactic body radiation for prostate cancer, it’s essential to perform the procedure with image guidance,” said Miften. “The key is acquiring images immediately prior to treatment that ensure the anatomy matches the planning CT.”
 
For more information: www.iopscience.iop.org

Related Content

News | Radiation Oncology

May 2, 2025 — GE HealthCare has announced an intended expansion of its radiation oncology portfolio as well as the ...

Time May 03, 2025
arrow
News | Radiology Education

April 21, 2025 — On June 20, the American Society of Radiologic Technologists (ASRT) will award Life Member status to ...

Time April 21, 2025
arrow
News | Radiology Business

April 16, 2025 — According to a new report, the U.S. Radiotherapy Market is projected to reach $2.49 billion by 2030 ...

Time April 17, 2025
arrow
News | ASTRO

March 14, 2025 — Another pivotal milestone in the nation’s fight against cancer recently took place with the ...

Time March 17, 2025
arrow
News | Computed Tomography (CT)

Royal Philips recently received 510(k) clearance from the US Food and Drug Administration (FDA) for its detector-based ...

Time November 13, 2024
arrow
News

Aug. 5, 2024 — Researchers from The University of Texas MD Anderson Cancer Center have demonstrated that adding ...

Time August 09, 2024
arrow
News | PET-CT

July 31, 2024 — In a head-to-head comparison with FDG PET/CT, FDG PET/MRI demonstrated comparable or superior diagnostic ...

Time July 31, 2024
arrow
Feature | Radiation Oncology | By Christine Book

News emerging from several leading organizations and vendors in the radiation therapy arena came in at a fast pace in ...

Time July 30, 2024
arrow
News | Radiopharmaceuticals and Tracers

July 24, 2024 — Telix Pharmaceuticals Limited announced that the United States (U.S.) Food and Drug Administration (FDA) ...

Time July 24, 2024
arrow
News | Radiation Oncology

July 11, 2024 — The American Society for Radiation Oncology (ASTRO) issued the following statement from Jeff M ...

Time July 11, 2024
arrow
Subscribe Now