News | November 14, 2013

Balloon Mispositioning During Prostate Cancer Treatment Could Affect Success of Radiation Delivery

November 14, 2013 — A University of Colorado Cancer Center study, published in the journal Physics in Medicine and Biology, shows that endorectal balloons commonly used during precise radiation treatment for prostate cancer can deform the prostate in a way that could make radiation miss its mark.
 
“Use of a balloon allows you to stabilize the anatomy,” said Moyed Miften, Ph.D, FAAPM, investigator, University of Colorado Cancer Center and chief physicist, department of radiation oncology, University of Colorado School of Medicine. “But what we show is that imprecision with balloon placement could reduce radiation dose coverage over the intended area.”
 
Specifically, Miften and colleagues studied the technique known as stereotactic body radiation, in which powerful, precisely-targeted radiation is delivered only to cancerous areas of the prostate with the hope of killing tumor tissue. An endorectal balloon is needed to hold the prostate in place while this high dose is delivered. The study used 71 images of nine patients to show an average endorectal balloon placement error of 0.5 cm in the inferior direction. The placement errors led to less precise radiation targeting and to uneven radiation dose coverage over cancerous areas.
 
“In radiation oncology, we use a CT (computed tomography) scan to image a patient’s prostate and then plan necessary treatment,” said Miften. “But if during treatment the prostate doesn’t match this planning image, we can deliver an imprecise dose.”
 
With the use of endorectal balloon, Miften and colleagues found prostates could be slightly pushed or squeezed, resulting in the prostate deforming slightly from its original shape and also sometimes tilting slightly from its original position in the body. These deformations can push parts of the prostate outside the area reached by the planned radiation.
 
“What we see is that whether or not a clinician chooses to use an endorectal balloon along with stereotactic body radiation for prostate cancer, it’s essential to perform the procedure with image guidance,” said Miften. “The key is acquiring images immediately prior to treatment that ensure the anatomy matches the planning CT.”
 
For more information: www.iopscience.iop.org

Related Content

First Hospitals Achieve Inter-System Connectivity Across Accuray Radiation Therapy Platforms
News | Radiation Therapy | January 19, 2018
Accuray Inc. announced recently that the Heidelberg University Hospital in Heidelberg, Germany, and Oscar Lambret...
RayStation Selected for New Carbon Ion Therapy Center in Japan
News | Treatment Planning | January 18, 2018
January 18, 2018 – RayStation has been chosen as the treatment planning system for a new carbon-ion therapy facility
Raysearch Receives First Order for the Raycare Oncology Information System
News | Oncology Information Management Systems (OIMS) | January 18, 2018
January 18, 2018 – Anderson Regional Cancer Center (ARCC) in Meridian, Mississippi, has placed the first order for...
Mevion Receives 510(k) Clearance for Hyperscan Pencil Beam Scanning Proton Therapy
Technology | Proton Therapy | January 04, 2018
Mevion Medical Systems has received U.S. Food and Drug Administration (FDA) 510(k) clearance for the Mevion S250i...
Study Compares Radiosurgery and Whole-Brain Radiation in Lung Cancer Patients With Multiple Brain Metastases
News | Radiation Therapy | January 03, 2018
Although targeted therapies have produced dramatic advances in the ability to control some types of advanced lung...
MEDraysintell Downgrades Proton Therapy Market Projection for 2030
News | Proton Therapy | January 02, 2018
MEDraysintell recently downgraded its projection for proton therapy rooms expected to be operational in 2030 from 1,200...
California US Oncology Network Centers Adopt Xoft Electronic Brachytherapy System for Early-Stage Non-Melanoma Skin Cancer
News | Brachytherapy Systems | January 02, 2018
iCAD Inc. announced that its Xoft Axxent Electronic Brachytherapy (eBx) System is now available at two California-based...
Blue Phantom System Used for Acceptance of First European Varian Halcyon Machine
News | Radiation Therapy | January 02, 2018
IBA (Ion Beam Applications S.A.) announced in November the acceptance and beam model validation of the first Varian...
Study Finds Link Between Breast Cancer Treatments and Cellular Aging Markers
News | Women's Health | January 02, 2018
January 2, 2018 — A new study found women who had received chemotherapy and/or...
ACR Appropriateness Criteria Adds and Revises Topics for December 2017
News | Clinical Decision Support | December 29, 2017
December 29, 2017 — Radiologists can enhance the quality and effectiveness of care with the newest release of the ACR
Overlay Init