Feature | May 15, 2012 | Dave Fornell

Trends and Advances in Cardiac SPECT and SPECT/CT

Myocardial perfusion study performed on a Philips Precedence SPECT/CT system showing ischemia.

Single photon emission computed tomography (SPECT) remains a well-entrenched imaging modality for nuclear myocardial perfusion imaging (MPI) more than 30 years after its introduction. Due to SPECT’s reliability, cost-effectiveness and the wealth of data showing its clinical validation, it remains more common in MPI than its competition, positron emission tomography (PET). This is despite data showing PET’s much shorter scan times, fewer artifacts and better accuracy. 

The high cost of the only FDA-approved, generator-based PET MPI agent, CardioGen-82, is a key factor keeping SPECT as the dominant modality. Cardiac PET took a further blow this past year when CardioGen-82 was abruptly pulled off the U.S. market in July 2011, after two patients set off radiation detectors at U.S. border crossings due to strontium breakthroughs. The agent uses a strontium (Sr)-82 generator to produce a rubidium (Rb)-82 radiotracer injection, but it requires close daily monitoring to prevent breakthroughs. The manufacturer, Bracco, is working with the FDA to bring the radiotracer back to market.

While SPECT technology has remained somewhat stagnant over the years, recent advances have improved the speed of exams and the diagnostic accuracy of the modality. 

New gamma camera technology has allowed imaging times to be reduced from about 15-20 minutes down to about two to four minutes. Advances include both new camera design for better photon acquisition and sensitivity and better image reconstruction software.[1] 

Wide beam reconstruction (WBR), a software program from UltraSPECT, reduces both dose and image acquisition time by 50 percent for SPECT MPI.[2] Researchers found that with either half the dose of Tc-99m sestamibi or half the acquisition time, WBR resulted in image quality superior to processing with today’s widely used OSEM (ordered subset expectation maximization) software. WBR’s reconstruction algorithm incorporates depth-dependent resolution recovery and image noise modeling to deliver a higher quality image with lower count density data. 

Newer Systems

The adoption of combined SPECT/CT in one imaging system using a single patient table is growing. The combination of CT (computed tomography) offers anatomical imaging in addition to the functional molecular imaging of SPECT. In addition, CT is used for attenuation correction, resulting in better SPECT image quality and reduction in attenuation artifacts, especially in obese patients. 

A major trend is the development of new dedicated cameras/detectors for cardiac-specific imaging. Spectrum Dynamics D-SPECT last year introduced a new-generation cadmium zinc telluride (CZT) detector that enables high-resolution, low-dose nuclear scans.

Frost & Sullivan recently recognized Siemens with the 2011 North America Product Differentiation Excellence of the Year Award for its IQ-SPECT system. It offers high-quality imaging by achieving maximum counts in one-fourth the amount of time required by conventional SPECT systems. The system features special collimators to focus on the heart, collecting up to four times more counts than conventional, parallel-hole collimators. A 3-D reconstruction algorithm models the position of each of the 48,000 collimator holes on each detector. This enables sophisticated distant-dependent isotropic (3-D) resolution recovery. It can complete a full SPECT scan in as little as four minutes. 

GE Healthcare received U.S. clearance for the Brivo NM615 in January. The advanced single-head gamma camera enables lower amounts (up to 50 percent) of radiotracers and the potential for shorter exam times. This is made possible with a new detector design. The system is designed to handle larger patients with a 70 cm bore and table capable of handling patients up to 500 pounds. The system can be upgraded easily onsite to the Discovery NM630 or the Discovery NM/CT 670 SPECT/CT hybrid systems.  

Comparison Chart

This story was an introduction to the SPECT and SPECT/CT comparison cahrt that appeared in the May-June 2012 issue of DAIC. To access the chart, click on the "Comparison Chart" tab at the top of the website page. Participants in the chart include:

 

Digirad - www.digirad.com

GE Healthcare - www.gehealthcare.com

Philips Healthcare - www.healthcare.philips.com

Siemens Medical Solutions - www.medical.siemens.com

 

References:
1. Tali Sharir, Piotr J. Slomka, Sean W. Hayes, et al. “Multicenter Trial of High-Speed Versus Conventional Single-Photon Emission Computed Tomography Imaging: Quantitative Results of Myocardial Perfusion and Left Ventricular Function.” JACC, May 4, 2010, Vol. 55, No. 18.
2. E. Gordon DePuey MD, Srinivas Bommireddipalli MD, John Clark CNMT, “A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT.” Journal of Nuclear Cardiolog, April 2011, Vol. 18, No. 2. 

Related Content

Biodex Unveils Atomlab 500 Dose Calibrator and Wipe Test Counter
Technology | Nuclear Imaging | October 19, 2017
Biodex Medical Systems announced the full release of the Atomlab Dose Calibrator and Wipe Test Counter to the market...
ASNC and ASE Team Up to Expand ImageGuide Registry
News | Cardiovascular Ultrasound | October 12, 2017
The American Society of Nuclear Cardiology (ASNC) and the American Society of Echocardiography (ASE) jointly announced...
MR Solutions Showcases Multimodality MRI Solutions on Two Continents
News | Magnetic Resonance Imaging (MRI) | October 11, 2017
October 11, 2017 — MR Solutions took their cryogen-free preclinical multimodality...
Majority of Recurrent Prostate Cancer Patients' Treatment Plan Changed Following Fluciclovine 18F PET/CT
News | Prostate Cancer | October 04, 2017
Blue Earth Diagnostics recently announced the results of a pre-planned interim analysis from an investigational...
News | Business | September 19, 2017
September 19, 2017 — Invicro LLC, a provider of imaging services and software for research and drug development, anno
ScImage and Invia Partnership Announced
News | PACS | September 19, 2017
ScImage Inc. and Invia Imaging Solutions recently announced formation of a joint partnership at the American Society of...
Toshiba Highlights Latest CT Advancements at RSNA 2017
News | Computed Tomography (CT) | September 18, 2017
Toshiba Medical announced that it will display several new enhancements to its existing computed tomography (CT)...
Philips Launches CardioMD IV Cardiac SPECT Solution at ASNC 2017
Technology | SPECT Imaging | September 15, 2017
September 15, 2017 — Philips highlighted its newest solution for...
Double Targeting Ligands to Identify and Treat Prostate Cancer

The mice were imaged with small-animal PET/CT using 124I-RPS-027 (7.4 MBq [200 μCi]). Credit: JM Kelly et al., Department of Radiology, Weill Cornell Medicine, New York, NY

News | Prostate Cancer | September 14, 2017
Researchers have demonstrated a new, effective way to precisely identify and localize prostate cancer tumors while...
Blue Earth Diagnostics Announcing Results of FALCON PET/CT Trial at ASTRO 2017
News | PET-CT | September 13, 2017
September 13, 2017 — Blue Earth Diagnostics announced the upcoming oral presentation of initial results from the FALC
Overlay Init