Feature | May 15, 2012 | Dave Fornell

Trends and Advances in Cardiac SPECT and SPECT/CT

Myocardial perfusion study performed on a Philips Precedence SPECT/CT system showing ischemia.

Myocardial perfusion study performed on a Philips Precedence SPECT/CT system showing ischemia.

Single photon emission computed tomography (SPECT) remains a well-entrenched imaging modality for nuclear myocardial perfusion imaging (MPI) more than 30 years after its introduction. Due to SPECT’s reliability, cost-effectiveness and the wealth of data showing its clinical validation, it remains more common in MPI than its competition, positron emission tomography (PET). This is despite data showing PET’s much shorter scan times, fewer artifacts and better accuracy. 

The high cost of the only FDA-approved, generator-based PET MPI agent, CardioGen-82, is a key factor keeping SPECT as the dominant modality. Cardiac PET took a further blow this past year when CardioGen-82 was abruptly pulled off the U.S. market in July 2011, after two patients set off radiation detectors at U.S. border crossings due to strontium breakthroughs. The agent uses a strontium (Sr)-82 generator to produce a rubidium (Rb)-82 radiotracer injection, but it requires close daily monitoring to prevent breakthroughs. The manufacturer, Bracco, is working with the FDA to bring the radiotracer back to market.

While SPECT technology has remained somewhat stagnant over the years, recent advances have improved the speed of exams and the diagnostic accuracy of the modality. 

New gamma camera technology has allowed imaging times to be reduced from about 15-20 minutes down to about two to four minutes. Advances include both new camera design for better photon acquisition and sensitivity and better image reconstruction software.[1] 

Wide beam reconstruction (WBR), a software program from UltraSPECT, reduces both dose and image acquisition time by 50 percent for SPECT MPI.[2] Researchers found that with either half the dose of Tc-99m sestamibi or half the acquisition time, WBR resulted in image quality superior to processing with today’s widely used OSEM (ordered subset expectation maximization) software. WBR’s reconstruction algorithm incorporates depth-dependent resolution recovery and image noise modeling to deliver a higher quality image with lower count density data. 

Newer Systems

The adoption of combined SPECT/CT in one imaging system using a single patient table is growing. The combination of CT (computed tomography) offers anatomical imaging in addition to the functional molecular imaging of SPECT. In addition, CT is used for attenuation correction, resulting in better SPECT image quality and reduction in attenuation artifacts, especially in obese patients. 

A major trend is the development of new dedicated cameras/detectors for cardiac-specific imaging. Spectrum Dynamics D-SPECT last year introduced a new-generation cadmium zinc telluride (CZT) detector that enables high-resolution, low-dose nuclear scans.

Frost & Sullivan recently recognized Siemens with the 2011 North America Product Differentiation Excellence of the Year Award for its IQ-SPECT system. It offers high-quality imaging by achieving maximum counts in one-fourth the amount of time required by conventional SPECT systems. The system features special collimators to focus on the heart, collecting up to four times more counts than conventional, parallel-hole collimators. A 3-D reconstruction algorithm models the position of each of the 48,000 collimator holes on each detector. This enables sophisticated distant-dependent isotropic (3-D) resolution recovery. It can complete a full SPECT scan in as little as four minutes. 

GE Healthcare received U.S. clearance for the Brivo NM615 in January. The advanced single-head gamma camera enables lower amounts (up to 50 percent) of radiotracers and the potential for shorter exam times. This is made possible with a new detector design. The system is designed to handle larger patients with a 70 cm bore and table capable of handling patients up to 500 pounds. The system can be upgraded easily onsite to the Discovery NM630 or the Discovery NM/CT 670 SPECT/CT hybrid systems.  

Comparison Chart

This story was an introduction to the SPECT and SPECT/CT comparison cahrt that appeared in the May-June 2012 issue of DAIC. To access the chart, click on the "Comparison Chart" tab at the top of the website page. Participants in the chart include:

 

Digirad - www.digirad.com

GE Healthcare - www.gehealthcare.com

Philips Healthcare - www.healthcare.philips.com

Siemens Medical Solutions - www.medical.siemens.com

 

References:
1. Tali Sharir, Piotr J. Slomka, Sean W. Hayes, et al. “Multicenter Trial of High-Speed Versus Conventional Single-Photon Emission Computed Tomography Imaging: Quantitative Results of Myocardial Perfusion and Left Ventricular Function.” JACC, May 4, 2010, Vol. 55, No. 18.
2. E. Gordon DePuey MD, Srinivas Bommireddipalli MD, John Clark CNMT, “A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT.” Journal of Nuclear Cardiolog, April 2011, Vol. 18, No. 2. 

Related Content

MIM Software Inc. Receives FDA 510(k) Clearance for Molecular Radiotherapy Dosimetry
Technology | Nuclear Imaging | January 16, 2019
MIM Software Inc. received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for molecular radiotherapy...
Videos | SPECT-CT | December 12, 2018
This is a walk around of the new Spectrum Dynamics Veriton SPECT-CT nuclear imaging system introduced at the 2018 ...
Spectrum Dynamics Sues GE for Theft, Misappropriation of Trade Secrets and Unfair Competition
News | SPECT Imaging | December 06, 2018
Single-photon emission computed tomography (SPECT) cardiac imaging company Spectrum Dynamics filed a lawsuit Dec. 6,...
Subtle Medical Receives FDA Clearance, CE Mark for SubtlePET
Technology | PET Imaging | December 05, 2018
Subtle Medical announced 510(k) clearance from the U.S. Food and Drug Administration (FDA) to market SubtlePET. Subtle...
Mirada Medical Joins U.K. Consortium Exploring Healthcare AI
News | Artificial Intelligence | December 04, 2018
Mirada Medical, a leading global brand in medical imaging software, will form part of an artificial intelligence (AI)...
GE Healthcare Recalls Millennium Nuclear Medicine Systems
News | Nuclear Imaging | November 15, 2018
GE Healthcare announced it is recalling its Millennium Nuclear Medicine Systems due to an incident in which the the top...
Artificial Intelligence Predicts Alzheimer's Years Before Diagnosis
News | Neuro Imaging | November 14, 2018
Artificial intelligence (AI) technology improves the ability of brain imaging to predict Alzheimer’s disease, according...
Researchers Awarded 2018 Canon Medical Systems USA/RSNA Research Grants
News | Radiology Imaging | November 13, 2018
The Radiological Society of North America (RSNA) Research & Education (R&E) Foundation recently announced the...
Subtle Medical Showcases Artificial Intelligence for PET, MRI Scans at RSNA 2018
News | Artificial Intelligence | November 13, 2018
At the 2018 Radiological Society of North America annual meeting (RSNA 2018), Nov. 25-30 in Chicago, Subtle Medical...
University of Missouri Research Reactor First U.S. I-131 Supplier in 30 Years

MURR is the only supplier of I 131 in the United States and the first U.S. supplier since the 1980s. Image courtesy of University of Missouri

News | Radiopharmaceuticals and Tracers | November 13, 2018
The University of Missouri Research Reactor (MURR) recently shipped its first batch of Iodine-131 (I-131), a...