33-year-old, low risk of acute coronary syndrome, presents to off-hour ED with acute chest pain

33-year-old, low risk of acute coronary syndrome, presents to off-hour ED with acute chest pain. Patient underwent coronary CTA using 64-detector row SSCT scanner, with heart rate control. Mean heart rate during acquisition was 89 bpm. Curved MPR images of right coronal artery (A), left anterior descending coronary artery (B), and left circumflex coronary artery (C) show poor image quality. Severe motion artifact is present in distal segments of RCA and LCX, and additional artifact from chest wall movement is present in proximal portion of left main coronary artery, leading to nondiagnostic examination. CT completion time was 236 minutes, disposition time was 79 minutes, and ED LOS was 601 minutes. Patient was discharged from ED without cardiology consultation, and did not undergo invasive coronary angiography or revascularization, nor experienced 30-day all-cause mortality or major adverse cardiovascular event


March 1, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), using a dual-source CT (DSCT) scanner for coronary CTA can facilitate clinical processes by eliminating the need to administer beta-blockers for heart rate control while decreasing nondiagnostic examinations.

“The findings indicate the potential role of a DSCT scanner with high temporal resolution to help expedite clinical processes in the emergency department (ED) setting,” concluded corresponding author Young Joo Suh, MD, PhD, from Korea’s Research Institute of Radiological Science at the Center for Clinical Imaging Data in Seoul. 

This AJR accepted manuscript included 509 patients (mean age, 52.1 years; 283 men, 226 women) at low-to-intermediate risk for acute coronary syndrome who underwent coronary CTA for acute chest pain in a single ED during the off hours of March 1, 2020 to April 25, 2022. A total 205 patients initially underwent CTA using a 64-detector single-source CT (SSCT) with heart rate control—oral beta-blocker administration if heart rate was faster than 65 beats per minute. Following scanner replacement on April 26, 2021, 304 patients underwent CTA using a third-generation DSCT without heart rate control. Cohorts were compared via length of stay (LOS) in the ED, as well as CT completion time (i.e., from ordering CTA to complete acquisition). Additional endpoints for Suh et al. included image quality and nondiagnostic examinations based on radiology reports.

Ultimately, DSCT without heart rate control—compared to SSCT with heart rate control—showed no difference in ED LOS (505 vs. 457 minutes; p=.37), but shorter CT completion time (95 vs. 117 minutes; p<.001), lower frequency of nondiagnostic examinations (1.6% vs. 6.3%, p=.01), and no difference in cardiology consultation, angiography, disposition, or revascularization (p>.05).

Noting an array of factors, especially patient disposition and onboarding processes, can affect overall length of stay, “the reduction in CT completion time through use of the DSCT system can still provide overall benefit in the ED setting,” the authors of this AJR accepted manuscript added.

For more information: www.arrs.org


Related Content

News | X-Ray

Aug. 10, 2026 — Teledyne Technologies Inc. and Varex Imaging Corp. have jointly announced that they have entered into a ...

Time August 14, 2026
arrow
News | Breast Imaging

Aug. 13, 2026 – Perimeter Medical Imaging AI recently announced that Intermountain Health, the largest nonprofit health ...

Time August 14, 2026
arrow
News | FDA

Aug. 1, 2026 — Candelis recently announced that the U.S. Food and Drug Administration (FDA) has granted 510(k) clearance ...

Time August 13, 2026
arrow
News | Artificial Intelligence

Aug. 10, 2026 — OSF HealthCare, a not-for-profit health system serving communities across Illinois and Michigan, and ...

Time August 12, 2026
arrow
News | Lung Imaging

Aug. 11, 2026 — Noah Medical has launched the Galaxy II software, the next evolution of its robotic-assisted ...

Time August 10, 2026
arrow
News | Radiology Business

Aug. 4, 2026 — Canon Medical Systems USA (CMSU) has appointed Tsuneo "Neo" Imai as president and chief executive officer ...

Time August 10, 2026
arrow
News | RSNA

Registration for RSNA 2026 is now open. The Radiological Society of North America's annual meeting will take place Nov ...

Time July 31, 2026
arrow
News | Innovative Hospitals

July 27, 2026 — Vanderbilt Health and Siemens Healthineers have entered into a multi-year, $87 million Value ...

Time July 28, 2026
arrow
News | Computed Tomography (CT)

July 23, 2026 — HOPPR has introduced HOPPR EF Chest CT Narrative Model, a foundation model that processes 3D chest CT ...

Time July 27, 2026
arrow
News | Pediatric Imaging

July 17, 2026 — In June, UW Health Kids began welcoming patients into a new state-of-the-art imaging suite dedicated to ...

Time July 23, 2026
arrow
Subscribe Now