52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.

52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.


February 16, 2022—According to an article in ARRS’ American Journal of Roentgenology (AJR), digital breast tomosynthesis (DBT) spot compression view could help characterize equivocal DBT findings, thus reducing further workup for benign findings.

Noting that DBT spot compression increased both intrareader and interreader agreement and improved diagnostic accuracy, primarily from improved specificity, “the view’s supplemental dose was slightly higher than that of a standard DBT view,” corresponding author Foucauld Chamming’s of Institut Bergonié in Bordeaux, France acknowledged.

The all-French team’s retrospective study included 102 women (mean age, 60 years) for whom a DBT spot compression was acquired to characterize an equivocal finding on DBT (via the performing radiologist’s discretion) from December 14, 2018 to December 18, 2019. Conscious of the equivocal lesions’ location, two fellowship-trained breast radiologists and one breast imaging fellow independently reviewed all examinations—assigning an initial BI-RADS category using standard DBT views, immediately followed by a category using DBT spot compression.

Based on kappa coefficients for DBT with and without spot compression views, intrareader agreement increased from 0.43 to 0.72, and interreader agreement increased from 0.21 to 0.45. Additionally, for all three readers, DBT spot compression views yielded significantly increased accuracy, as well as significantly increased specificity.

Adding that their study is the first to evaluate the impact of obtaining DBT spot compression for equivocal findings on DBT, “the results support the utility of spot compression views for aiding evaluation of subtle or ambiguous findings encountered on DBT in clinical practice,” the authors of this AJR article concluded.

For more information: www.arrs.org

Related Digital Breast Tomosynthesis Content:

AI DBT Impact on Mammography Post-breast Therapy

ImageCare Centers Unveils PINK Better Mammo Service Featuring Profound AI

Radiologist Fatigue, Experience Affect Breast Imaging Call Backs

Fewer Breast Cancer Cases Between Screening Rounds with 3-D Mammography


Related Content

News | Ultrasound Women's Health

Sept. 29, 2026 — A research team at the University of Virginia (UVA) led by Timothy Bullock, PhD, has published results ...

Time September 30, 2026
arrow
News | Breast Imaging

Sept. 10, 2026 — An artificial intelligence model that analyzes women's past and recent annual 3D mammograms is more ...

Time September 10, 2026
arrow
News | Ultrasound Women's Health

Sept. 3, 2026 — Royal Philips has introduced the eV14-2v transvaginal transducer, expanding its obstetrics and ...

Time September 04, 2026
arrow
News | Women's Health

Sept. 1, 2026 — On Sept. 24, 2026 at 1 p.m. EDT, Siemens Healthineers will present a webinar on "Advancing Women's ...

Time September 03, 2026
arrow
News | Breast Imaging

Aug. 13, 2026 – Perimeter Medical Imaging AI recently announced that Intermountain Health, the largest nonprofit health ...

Time August 14, 2026
arrow
News | Breast Imaging

Aug. 3, 2026 — QT Imaging Holdings, is advancing the direct U.S. commercial strategy for its Breast Acoustic CT Scanner ...

Time August 04, 2026
arrow
News | Breast Imaging

Aug. 3, 2026 — GE HealthCare has launched Invenia ABUS (Automated Breast Ultrasound) Prime and ABUS StreamVue, a ...

Time August 03, 2026
arrow
News | Breast Imaging

July 30, 2026 — DeepHealth, Inc. has received FDA 510(k) clearance for DeepHealth Breast Ultrasound1, an AI-powered ...

Time July 31, 2026
arrow
News | Computed Tomography (CT)

July 23, 2026 — HOPPR has introduced HOPPR EF Chest CT Narrative Model, a foundation model that processes 3D chest CT ...

Time July 27, 2026
arrow
News | Magnetic Resonance Imaging (MRI)

July 7, 2026 — Imagion Biosystems, Ltd. recently announced it has renewed and extended its collaboration agreement with ...

Time July 07, 2026
arrow
Subscribe Now