52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.

52-Year-Old Woman Presenting for Asymmetry of Right Breast: (A) DBT craniocaudal view shows asymmetry (arrow) in medial right breast (DBT). (B) DBT spot compression view shows asymmetry does not persist (arrowhead). Lesion classified on DBT without, and DBT with, DBT spot compression view as BI-RADS category 4a and 2 by reader 1, category 4a and 2 by reader 2, and category 4b and 2 by reader 3. Follow-up imaging at one year demonstrated stability of finding, consistent with benignity in present analysis.


February 16, 2022—According to an article in ARRS’ American Journal of Roentgenology (AJR), digital breast tomosynthesis (DBT) spot compression view could help characterize equivocal DBT findings, thus reducing further workup for benign findings.

Noting that DBT spot compression increased both intrareader and interreader agreement and improved diagnostic accuracy, primarily from improved specificity, “the view’s supplemental dose was slightly higher than that of a standard DBT view,” corresponding author Foucauld Chamming’s of Institut Bergonié in Bordeaux, France acknowledged.

The all-French team’s retrospective study included 102 women (mean age, 60 years) for whom a DBT spot compression was acquired to characterize an equivocal finding on DBT (via the performing radiologist’s discretion) from December 14, 2018 to December 18, 2019. Conscious of the equivocal lesions’ location, two fellowship-trained breast radiologists and one breast imaging fellow independently reviewed all examinations—assigning an initial BI-RADS category using standard DBT views, immediately followed by a category using DBT spot compression.

Based on kappa coefficients for DBT with and without spot compression views, intrareader agreement increased from 0.43 to 0.72, and interreader agreement increased from 0.21 to 0.45. Additionally, for all three readers, DBT spot compression views yielded significantly increased accuracy, as well as significantly increased specificity.

Adding that their study is the first to evaluate the impact of obtaining DBT spot compression for equivocal findings on DBT, “the results support the utility of spot compression views for aiding evaluation of subtle or ambiguous findings encountered on DBT in clinical practice,” the authors of this AJR article concluded.

For more information: www.arrs.org

Related Digital Breast Tomosynthesis Content:

AI DBT Impact on Mammography Post-breast Therapy

ImageCare Centers Unveils PINK Better Mammo Service Featuring Profound AI

Radiologist Fatigue, Experience Affect Breast Imaging Call Backs

Fewer Breast Cancer Cases Between Screening Rounds with 3-D Mammography


Related Content

News | Breast Imaging

Nov. 17, 2025 — RadNet, Inc. and its wholly owned subsidiary, DeepHealth have announced results from the largest real ...

Time November 17, 2025
arrow
News | Radiology Business

Nov. 12, 2025 — Siemens has announced plans to deconsolidate its remaining stake in Siemens Healthineers (currently ...

Time November 13, 2025
arrow
News | Artificial Intelligence

Nov. 6, 2025 — Lunit, a provider of AI for cancer diagnostics and precision oncology, recently announced that Volpara ...

Time November 07, 2025
arrow
News | RSNA 2025

Nov. 3, 2025 — QT Imaging Holdings has announced that its chief medical officer, Elaine luanow, MD, will host a seminar ...

Time November 04, 2025
arrow
News | Breast Imaging

Oct. 28, 2025 — QT Imaging Holdings, Inc., a medical device company focused on radiation-free imaging technology, has ...

Time October 28, 2025
arrow
Feature | Breast Imaging

Despite decades of progress in breast imaging, one challenge continues to test even the most skilled radiologists ...

Time October 24, 2025
arrow
News | Breast Imaging

Oct. 15, 2025 — Leading into Breast Cancer Awareness Month, Fujifilm Healthcare Americas Corp. and Beekley Medical ...

Time October 15, 2025
arrow
News | RSNA 2025

Oct. 7, 2025 – Clairity Inc., a leader in AI-based breast cancer risk prediction, will make five scientific ...

Time October 07, 2025
arrow
News | Breast Imaging

Oct. 3, 2025 — Gnosis for Her, a mobile breast health initiative redefining comfort and access in women's breast imaging ...

Time October 06, 2025
arrow
News | Mammography | Mayo Clinic

Early detection is key to breast cancer survival. But nearly half of all women in the U.S. have dense breast tissue ...

Time October 03, 2025
arrow
Subscribe Now