News | Radiation Therapy | December 07, 2015

The technique could improve outcomes by increasing radiation dose to rumors, decreasing toxicity

December 7, 2015 — A new brachytherapy technique using a shield that rotates in a corkscrew pattern inside a tube-shaped intrauterine applicator could improve cervical cancer treatments, boosting the radiation dose while sparing the healthy tissue around it. Researchers report on the technique in the current issue of Medical Physics, the monthly journal of the American Association of Physicists in Medicine (AAPM), the professional organization of medical physicists, who ensure radiation therapy and imaging procedures are safe and effective.

Current cervical brachytherapy technology involves depositing doses of radiation directly in tumors using sources that emit radiation nearly uniformly around the source. This limits the ability to personalize treatment as the physician may be unable to deliver a desired tumor dose due to limitations imposed by nearby healthy tissues such as the bladder, colon and rectum.

The new technique improves upon the current technology by fitting a rotating shield to the source catheter that delivers the radiation to the tumor. The shield rotates around the radiation source following grooves in the inner wall of the applicator that are shaped like a series of corkscrews (helixes). This new method would allow physicians to provide patients personalized radiation therapy by choosing different grooves to guide treatment and rotating the shield to block the radiation from reaching healthy tissues.

“The multihelix rotating shield delivery technique could enable physicians to deliver doses of radiation to tumors with a degree of conformity that is not possible with conventional, unshielded brachytherapy sources,” said Ryan T. Flynn, Ph.D., the corresponding author and director of medical physics at the University of Iowa Hospitals and Clinics in Iowa City. “The resulting treatment would be more targeted, less toxic and could improve cervical cancer therapy.”

Researchers simulated the delivery of the dose distribution with the proposed technique based on imaging and data of five women with cervical cancer who were treated with external beam radiation therapy and conventional brachytherapy methods. The team found the multihelix rotating shield brachytherapy method to be technically feasible to deliver, and determined that a higher radiation dose could be delivered to the tumor than is possible with conventional techniques without exceeding the tolerance doses of the bladder, rectum and colon. The goal of the research team is to build a prototype of the multihelix rotating shield brachytherapy system and begin clinical trials in women in several years, Flynn said.

“This shows significant promise of a future in which women with cervical cancer could receive safer, more effective cancer treatment,” said M. Saiful Huq, Ph.D., chair of the AAPM Science Council Therapy Physics Committee and professor and director of medical physics at University of Pittsburgh Cancer Institute and UPMC CancerCenter. “The cutting-edge science demonstrates the leading role medical physicists play in pushing the envelope to continually improve patient care.”

Co-authors of the study in addition to Flynn are: Hossein Dadkhah, M.S., Yusung Kim Ph.D., and Xiaodong Wu, Ph.D., of the University of Iowa.

For more information: www.aapm.org


Related Content

News | Breast Imaging

Sept. 10, 2026 — An artificial intelligence model that analyzes women's past and recent annual 3D mammograms is more ...

Time September 10, 2026
arrow
News | Ultrasound Women's Health

Sept. 3, 2026 — Royal Philips has introduced the eV14-2v transvaginal transducer, expanding its obstetrics and ...

Time September 04, 2026
arrow
News | Radiation Oncology

Sept. 2, 2026 — Children with one of the deadliest forms of brain cancer may benefit from an additional course of ...

Time September 03, 2026
arrow
News | Breast Imaging

Aug. 13, 2026 – Perimeter Medical Imaging AI recently announced that Intermountain Health, the largest nonprofit health ...

Time August 14, 2026
arrow
News | Breast Imaging

Aug. 3, 2026 — QT Imaging Holdings, is advancing the direct U.S. commercial strategy for its Breast Acoustic CT Scanner ...

Time August 04, 2026
arrow
News | Breast Imaging

Aug. 3, 2026 — GE HealthCare has launched Invenia ABUS (Automated Breast Ultrasound) Prime and ABUS StreamVue, a ...

Time August 03, 2026
arrow
News | Breast Imaging

July 30, 2026 — DeepHealth, Inc. has received FDA 510(k) clearance for DeepHealth Breast Ultrasound1, an AI-powered ...

Time July 31, 2026
arrow
News | Breast Imaging

July 7, 2026 — QT Imaging Holdings, Inc. recently announced it has successfully completed its first routine inspection ...

Time July 07, 2026
arrow
News | MRI Breast

July 2, 2026 – Quibim has announced the European and UK launch of QP-Breast, its CE and UKCA-marked AI tool which ...

Time July 02, 2026
arrow
News | Mammography

June 30, 2026 — The Food and Drug Administration has cleared new contrast-enhanced mammography (CEM) and CEM biopsy ...

Time June 30, 2026
arrow
Subscribe Now