Technology | June 11, 2013

Siemens Introduces Continuous FlowMotion PET/CT

Biograph mCT Flow is the first PET/CT system with continuous motion scanning to improve image detail

June 11, 2013 — Siemens Healthcare has introduced Biograph mCT Flow, a positron emission tomography/computed tomography (PET/CT) system that, for the first time ever, overcomes the limitations of conventional bed-based PET/CT with FlowMotion, a new technology that moves the patient smoothly through the system’s gantry, while continuously acquiring PET data. Biograph mCT Flow with FlowMotion takes routine image quality to a new level by enabling imaging protocols based on the organ’s need.

FlowMotion expands quantification in all dimensions for precise disease characterization in therapy monitoring, while enabling physicians to offer as low as reasonably achievable (ALARA) dose to every patient. Additionally, the combination of a 78 centimeter bore with five-minute scanning and a continuous sense of progress throughout the scan provides the patient with a more comfortable exam experience.

Finest detail in every organ

With conventional PET/CT scanners, planning and scanning is limited to the fixed size of the system’s detector field of view (FOV) for each bed position. While the adjustment of scan parameters in clinical stop-and-go PET/CT protocols is technically possible, the complexity of adjustment has limited its routine use.

Biograph mCT Flow PET/CT with FlowMotion technology eliminates the need for stop-and-go, bed-based planning with planning and scanning based on the single continuous motion of the patient table. The technician can easily adjust the examination parameters such as speed, image resolution and motion management to the precise dimensions of organs and routinely incorporated into a single scan for every patient.
 
Accurate quantification in all dimensions

In order to help physicians make sound decisions, nuclear imaging must provide accurate and reproducible quantification. Conventional PET/CT suffers from intrinsic sensitivity degradation from the center to the edge of the axial FOV. Overlapping sequential bed positions are used to compensate for this constraint, but this approach can lead to axially varying noise sensitivity.  This noise can distort the quantitative values of a detected lesion, which may prompt a physician to mischaracterize the severity of a tumor. By continuously moving the patient through the detection system, FlowMotion technology eliminates overlapping bed acquisitions and maintains uniform noise sensitivity across the entire scan range.

Minimum dose and maximum speed

FlowMotion eliminates CT dose due to overscanning by enabling the user to precisely define the beginning and end of the PET scan – and since the CT scan of Biograph mCT Flow begins and ends at the same points as the system’s PET scan, the patient is not irradiated in areas of the body that do not require a CT scan. With Biograph mCT Flow, the user can realize a CT dose reduction of up to 32 percent. Meanwhile, the new Biograph mCT Flow, coupled with TrueV, enables continuous scanning at twice the speed of conventional PET/CT. TrueV technology provides a 30 percent wider axial FOV of 21.6 cm, enabling Biograph mCT Flow to provide a 70 percent increase in count rate performance. When combined with ultraHD/PET, which delivers increased image quality, routine clinical scans can be performed in five minutes. The user can employ a simple protocol setup to determine the scan type and duration for up to four zones — for example, the head, lungs, abdomen and legs. The user can then tailor the scan in each region using Siemens’ established image quality techniques.

Open comfort for all patients

Healthcare providers require a system that accommodates the individual needs of a wide patient demographic. A standard PET/CT scan can last 25 to 30 minutes, with the patient frequently falling asleep or zoning out while the system acquires a bed position. When the bed shifts to the next scanning position, the patient is often startled, resulting in an image that is marred by motion artifacts. The patient also can feel anxiety during the lengthy scanning process, perceiving no progress until the bed shifts to a new scanning position.

In addition to the elimination of patient motion due to surprise, the continuously moving patient table of Biograph mCT Flow gives the patients a sense of progress, which can further enhance patient satisfaction.  Additionally, the large 78 cm bore, short tunnel and a 500 pound table capacity can improve patient comfort and accessibility.

For more information: usa.healthcare.siemens.com

Related Content

PET/CT Changes Care for 59 Percent of Suspected Recurrent Prostate Cancer Cases
News | Prostate Cancer | June 13, 2018
A recently presented investigational clinical trial evaluated the impact of 18F fluciclovine positron emission...
Nuclear imaging scan showing very good tissue delineation. Scan performed on a Biograph Vision positron emission tomography/computed tomography (PET-CT) system from Siemens Healthineers.

Nuclear imaging scan showing very good tissue delineation. It offers crisp overall image quality and sharply delineates the muscle and fat planes, vertebral margins and end plates, billiary radicals, renal calyces, aortic wall and papillary muscles of the heart. Scan performed on a Biograph Vision positron emission tomography/computed tomography (PET-CT) system from Siemens Healthineers.

Technology | PET-CT | June 05, 2018
June 5, 2018 — The U.S.
Emerging Trends in Nuclear Medicine
Feature | Nuclear Imaging | June 04, 2018 | By Jeff Zagoudis
Nuclear imaging and its various modalities have long played an important role in the diagnosis and treatment of numer
News | Computed Tomography (CT) | May 21, 2018
The Istituto Oncologico Veneto (IOV) in Padua, Italy, has acquired MILabs’ latest-generation Versatile Emission...
PET Imaging Agent Could Provide Early Diagnosis of Rheumatoid Arthritis

Coronal 18F-FEDAC PET/CT section of a mouse with collagen-induced arthritis. (A) On day 23 and day 37, increased uptake is noted in the front and hind paws of this mouse with collagen-induced arthritis. (B) Predictive performance of day 23 18F-FEDAC uptake for the development of clinical arthritis. ROC = receiver operating characteristic; Sn = sensitivity; Sp = specificity. Credit: Seoul National University and Ewha Womans University, Seoul, South Korea

News | PET Imaging | May 17, 2018
A novel positron emission tomography (PET) tracer developed by Korean researchers can visualize joint inflammation and...
PET Imaging Shows Protein Clumping May Contribute to Heart Failure Development
News | PET Imaging | May 11, 2018
A team led by Johns Hopkins University Researchers has discovered that protein clumps appear to accumulate in the...
News | Radiopharmaceuticals and Tracers | May 09, 2018
Blue Earth Diagnostics signed an exclusive, worldwide agreement with Scintomics GmbH, Germany, a specialist in...
Novel PET Agent Could Help Guide Therapy for Brain Diseases

Rat brain 11C‐Me‐NB1 PET images (0‐60 min) superimposed on an MRI template. Credit: SD Krämer et al., ETH Zurich, Zurich, Switzerland

News | PET Imaging | April 10, 2018
Researchers have developed a new imaging agent that could help guide and assess treatments for people with various...
The Chalk River nuclear reactor license has been renewed, but will be decommissioned by 2028.

The Chalk River nuclear isotope reactor license has been renewed, but will be decommissioned by 2028. The reactor supplies about 50 percent of the world's supply of Tc99m.

Feature | Nuclear Imaging | April 02, 2018 | Dave Fornell
April 2, 2018 – The Canadian Nuclear Safety Commission (CNSC) announced March 29 that it renewed Canadian Nuclear Lab
Overlay Init