News | Radiation Therapy | February 18, 2020

A new gel-based nanosensor for radiation dose monitoring can be used on skin and is relatively inexpensive

Arizona State University researchers (in collaboration with Banner MD Anderson Cancer Center) have discovered a biocompatible cost-effective hydrogel that can be used to monitor therapeutic doses of ionizing radiation by becoming more pink with increasing radiation exposure

Arizona State University researchers (in collaboration with Banner MD Anderson Cancer Center) have discovered a biocompatible cost-effective hydrogel that can be used to monitor therapeutic doses of ionizing radiation by becoming more pink with increasing radiation exposure. This picture shows a circle of hydrogel that was irradiated on the left half, which is slightly pink; whereas the right half of the gel is not irradiated and remains colorless.


February 18, 2020 — More than half of all cancer patients undergo radiation therapy and the dose is critical. Too much and the surrounding tissue gets damaged, too little and the cancer cells survive. Subhadeep Dutta and Karthik Pushpavanam, graduate students working in the lab of Kaushal Rege, professor at Arizona State University in Tempe, and collaborators at Banner-M.D. Anderson in Gilbert, Ariz., developed a new way to monitor radiation doses that is cost-effective and easy to read. Dutta will present their research on Tuesday, February 18 at the 64th Annual Meeting of the Biophysical Society in San Diego, California.

Radiation therapy directs high energy beams to destroy the genetic material inside cells and prevent them from growing. Typically, a radiation therapy team decides the total dose of radiation, and then divides that total dose over several sessions. The machines and calculations involved are usually spot-on as far as dosages, but sometimes variations, perhaps due to patient movement such as breathing, or in rare instances due to issues with the machine or software, can be causes for error. Monitoring the dose is critical as both overdosing and underdosing can compromise patient safety — too much healthy tissue or too little tumor can be destroyed in the process.

Dutta, Pushpavanam, Rege and colleagues made a hydrogel that can be applied directly to a patient’s skin in order to easily measure radiation doses. Mixed into the hydrogel are gold salts and a few amino acids. Without radiation, the gel is colorless, but as it is exposed to radiation it becomes pink. The color intensity is directly correlated to the amount of radiation. At the end of a treatment, it is painlessly peeled off the skin and the color is measured with a common and relatively inexpensive lab instrument, an absorption spectrometer.

Some dose monitors are currently available for patients. “One looks like a sheet of paper (radiochromic films), but it is sensitive to light and heat, so it must be carefully handled, and requires long processing times. Another is a tiny sensor (NanoDot), which is expensive and requires multiple arrays to cover an area of the skin. Ours can be used directly onto the skin and is relatively inexpensive,” Dutta said.

The gel has performed well in testing and was recently used on canine cancer patients undergoing radiotherapy. “Our next plan is to convert it to an app-based system, where you can take a picture of a gel and that can predict the dose based on programming in the app. It’s just measuring color, which is easy to do,” said Dutta. The team is hopeful that future studies will lead to translation of this technology for use with human patients in the clinic.

For more information: www.biophysics.org/


Related Content

News | Artificial Intelligence

November 28, 2023 — iCAD, Inc., a global medical technology leader in innovative cancer-detection solutions, and ...

Time November 28, 2023
arrow
News | RSNA

November 28, 2023 — New research being presented this week at the annual meeting of the Radiological Society of North ...

Time November 28, 2023
arrow
News | Magnetic Resonance Imaging (MRI)

November 27, 2023 — Stronger quadriceps muscles, relative to the hamstrings, may lower the risk of total knee ...

Time November 27, 2023
arrow
News | Treatment Planning

November 26, 2023 — TeleDaaS, PLLC, a leading dosimetry-as-a-service provider, made its official debut today at the ...

Time November 26, 2023
arrow
News | Breast Imaging

November 21, 2023 —iCAD, Inc., a global medical technology leader in innovative cancer-detection solutions, and CancerIQ ...

Time November 21, 2023
arrow
News | Breast Imaging

November 20, 2023 — The American Society for Radiation Oncology (ASTRO) issued a clinical guideline on partial breast ...

Time November 20, 2023
arrow
News | Artificial Intelligence

November 15, 2023 — The 2023 Radiological Society of North America (RSNA) Alexander R. Margulis Award for Scientific ...

Time November 15, 2023
arrow
Feature | Radiology Business | By Melinda Taschetta-Millane

As another month comes to a close, ITN takes a look at the Top 10 most-read pieces of content from www.itnonline.com ...

Time November 06, 2023
arrow
News | ASTRO

November 3, 2023 —The American Society for Radiation Oncology (ASTRO) issued the following statement from Jeff M ...

Time November 03, 2023
arrow
Feature | Radiation Oncology | By Melinda Taschetta-Millane

Imaging advancements, including 3D Doppler imaging to detect cancers in numerous organs, are used to accurately guide ...

Time November 03, 2023
arrow
Subscribe Now